background image

www.extron.com

© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.

 

usa west

 

+1.714.491.1500 / +800.633.9876

 

+1.714.491.1517 FAX

 

usa east

 

+1.919.863.1794 / +800.633.9876

 

+1.919.863.1797 FAX

 

China

 

+86.21.3760.1568 / +400.883.1568

 

+86.21.3760.1566 FAX

 

 

Japan

 

 

+81.3.3511.7655

 

 

+81.3.3511.7656 FAX

europe

+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FAX

 

dubai 

 

+971.4.2991800 

 

 

+971.4.2991880 FAX

 

asia

    +65.6383.4400 / +800.7339.8766
 

+65.6383.4664 FAX

www.extron.com

© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.

 

usa west

 

+1.714.491.1500 / +800.633.9876

 

+1.714.491.1517 FAX

 

usa east

 

+1.919.863.1794 / +800.633.9876

 

+1.919.863.1797 FAX

 

China

 

+86.21.3760.1568 / +400.883.1568

 

+86.21.3760.1566 FAX

 

 

Japan

 

 

+81.3.3511.7655

 

 

+81.3.3511.7656 FAX

europe

+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FAX

 

dubai 

 

+971.4.2991800 

 

 

+971.4.2991880 FAX

 

asia

    +65.6383.4400 / +800.7339.8766
 

+65.6383.4664 FAX

sPecIFIcaTIons

cLock and TherMoMeTer

Clock accuracy

 . . . . . . . . . . . . . . . . . .  

<±30 seconds per month

Temperature display range

 . . . .  

+16 to +122 °F (-9 to +50 °C)

Temperature accuracy

 . . . . . . . . .  

±3 °F (±2 °C)

Temperature sampling 

interval

 . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 minute

Temperature sampling 

duration

 . . . . . . . . . . . . . . . . . . . . . . . . . . .  

0.1 to 0.2 s

GeneraL

Power

 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

Supplied by internal batteries

Batteries

Number / Signal type

 . . . . . . . . . . . . .  

1 AAA battery (1.2 to 1.7 V)

Operating life

 . . . . . . . . . . . . . . . . . . . . . .  

1 year

Standby current

 . . . . . . . . . . . . . . . . .  

20 µA

Temperature sampling 

current

 . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

300 µA

Temperature / Humidity

 . . . . . . . .  

Storage: +14 to +140 °F (-10 to +60 °C) / 10% to 90%, noncondensing 
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Rack mount

 . . . . . . . . . . . . . . . . . . . . . .  

Yes, with optional 1U rack shelf, part #60-190-01 or 60-604-01; or  
VersaTools

®

 rack shelf, part #60-190-20 or 60-604-20

Enclosure type

 . . . . . . . . . . . . . . . . . . .  

Metal

Enclosure dimensions

 . . . . . . . . . .  

1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide) 
4.2 cm H x 11.0 cm W x  7.6 cm D

Product weight

 . . . . . . . . . . . . . . . . . .  

0.3 lbs (0.1 kg)

Shipping weight

 . . . . . . . . . . . . . . . . .  

1 lbs (1 kg)

Vibration

 . . . . . . . . . . . . . . . . . . . . . . . . . .  

ISTA 1A in carton (International Safe Transit Association)

Compliances

 . . . . . . . . . . . . . . . . . . . . .  

CE

MTBF

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

30,000 hours

Warranty

 . . . . . . . . . . . . . . . . . . . . . . . . . .  

3 years parts and labor

NOTE: All nominal levels are at ±10%. Specifications are subject to change without notice.

  l c d   c l o c k S   &   t h e r M o M e t e r S

CLK 100

12/24 Hour LCD Clock with Thermometer

FeaTures

 

High contrast, easy-to-read LCD display with 0.8 inch (20 mm) character 
readout

 — The front panel display is easy to read from across the room, even under 

dim lighting conditions.

 

12/24 hour time and date display

 — Facilitates time/date logging for service calls and 

other applications.

 

Built-in thermometer with °F/°C temperature display

 — Continuous display 

of ambient temperature, updated every 60 seconds. The thermometer is useful in 
identifying potentially excessive room or equipment rack heat conditions.

 

Back panel sensor reads operating temperature inside equipment rack enclosure

 

Runs on a single AAA battery - included

 

Ideal for desktop or rack-mount applications

 

Rack-mountable 1U, quarter rack width metal enclosure

descrIPTIon

The Extron 

CLK 100

 is a versatile, battery-operated LCD clock with an integrated thermometer, 

ideal for monitoring the ambient temperature within an equipment rack or room. The CLK 100 
displays the date and time of day in either 12 hour or 24 hour format, and temperature in 
degrees Fahrenheit or Centigrade. Part of the VersaTools

®

 line of small, economical, integrator 

friendly products, the CLK 100 is housed in a 1U, quarter rack width metal enclosure for easy 
rack mounting with other VersaTools products, and is equally at home in desktop or shelf 
top applications.

ModeL

 

VersIon descrIPTIon

 

 

ParT #

 

 

CLK 100

 

LCD Clock with Thermometer

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

60-791-01

 

693

Reviews: