background image

Page 1

 

 
 
 
 
 

Instruction Manual  

 
 
 
 
 

 
 
 
 

Read the instruction manual 
carefully before using the 
equipment for the first time 
and before carrying out any 
maintenance work

 

 
 
 
 
 
 
 
 
 

For the following models:  

 
 

 

EP 1236-100 

 

EP 1236-100 Sensor 

 

EP 1236-140 

 
 
 
 

Serial number: 

 
 
 
 
__________________________________________ 
 
 

(status: August 2011) 

 

 

Summary of Contents for EP 1236-100

Page 1: ...anual carefully before using the equipment for the first time and before carrying out any maintenance work For the following models EP 1236 100 EP 1236 100 Sensor EP 1236 140 Serial number __________________________________________ status August 2011 ...

Page 2: ...um cleaner Connecting to the power supply 6 Switching on and off Duty time 7 Using the vacuum cleaner Appropriate use Residual risk analysis 8 Disposing of dirt Emptying the dirt box 9 Cleaning and replacing cartridge filter 10 Checks and inspections Prior to every shift After 200 hours of operation monthly After 2000 hours of operation yearly 11 Troubleshooting At the end of the instruction manua...

Page 3: ...The cleaner separates the swarfs from the liquids The swarfs remain in the swarf basket and the liquids trickle into the lower container For identification purposes please refer to the important data relating to power consumption dust class or cleaner serial number which appears on the nameplate see the example below Modell Typ XXXX 1 Staubklasse L M 2 Nennspannung 230 400 Volt 3 Nennaufnahme kW 4...

Page 4: ...s into the vents Do not use the equipment if a vent is blocked Do not allow the vents to become clogged with dust fibres hair or other materials which may restrict air flow Keep hair loose clothing fingers and other body parts away from vents and moving parts Do not use the equipment if the power cable or connector is damaged You must stop using the equipment immediately if it is not in perfect wo...

Page 5: ...connector supplied with it in any way If it cannot be connected to your mains supply have a qualified electrician fit a suitable power socket Do not extend the power cable The use of extension cables connection couplings or adapters is not permitted The machine must undergo an annual technical inspection to be carried out by the manufacturer or a qualified specialist Caution Unauthorised tampering...

Page 6: ... requirements of applicable national legislation Equipment which is no longer suitable for use must also be disposed of in compliance with the requirements of applicable legislation Installing the vacuum cleaner It is the user s responsibility to ensure that the vacuum cleaner is installed in compliance with local regulations This instruction manual must be read and its content understood The floo...

Page 7: ...is reached the probe of the liquid level control reacts the indicator light illuminates and the cleaner disrupts the suction process automatically Dirt box and swarf basket have to be emptied now If the indicator light remains on even once the dirt box and the swarf basket have been emptied this can mean that the probe used for checking the liquid level has become contaminated The probe is located...

Page 8: ...up a variety of substances there remains the risk of these substances combining to produce an unforeseeable chemical reaction Disposal of dirt Emptying the swarf basket and dirt container Run the vacuum cleaner hose empty Switch off the machine by actuating the ON OFF switch The liquid can be drained through the draining hose EP 1236 100 Lower the dirt container through the levers on both sides EP...

Page 9: ... deposit it carefully Twist off the screw joint of the cartridge filter Pull the cartridge filter from the pipe socket and replace it by a new cartridge filter of the same construction and characteristics If the filter should only be cleaned you can do that now The filter consists of water tolerant polypropylene and can be wet cleaned Achtung Der Patronenfilter muss zur Reinigung aus dem Gerät ent...

Page 10: ...ight There are no leaks The suction hose and tool are in good condition They must not be torn split or damaged beyond repair The power cable is not damaged twisted or squashed The cloth cartridge filter is not damaged and that there is no evidence of any tears or holes If the filter is damaged you must replace it The probe is free of contamination Every 2000 hours of operation yearly Check the con...

Page 11: ...Solution Have the probe replaced by a specialist Insufficient suction power Filter or hose is blocked Solution Clean filter or hose Box is full Solution Follow the instructions in the manual and empty the box Box not airtight Solution Locate and rectify the leak Excessive dirt in the cartridge filter Solution Clean filter Dust blowing out Switch the vacuum cleaner off immediately Filter faulty Sol...

Page 12: ...Elektromagnetische Verträglichkeit electromagnetic compatibility directive Angewandte harmonisierte Normen applied harmonized standards DIN EN 60335 1 10 12 DIN EN 60335 2 69 01 2010 Sicherheitsanforderungen Staub und Wassersauger Requirements for wet and dry vacuum DIN EN ISO 3744 02 2011 Bestimmung Schalleistungspegel Nationale Prüfgrundlagen National testing framework ZEK 01 4 08 11 2011 Polycl...

Page 13: ... replacement as a spare part 054 30075 Cartridge filter for swarf and emulsion vacuum cleaner EP 1236 to buy for replacement 1 0 m dia 50 cm 054 10059 PUR suction hose for swarf and emulsion vacuum cleaner EP 1236 with coupler for camlock coupling 3 5 m dia 50 mm 052 0278 5 0 m dia 50 mm 052 0279 Closure for Kamlock coupling For suction hose dia 50 mm 052 0261 EVOTEC ...

Page 14: ... curved tubular nozzles 100 mm and 200 mm one wall nozzle and one floor nozzle dia 40 mm 052 1090 dia 50 mm 052 1100 Industrial floor cleaning set for cleaning all floors Consisting of multi part hand tube metal revolving nozzle with brush strip and replacement rubber strip round brush nozzle dia 40 mm working width 370 mm 052 1030 dia 40 mm working width 450 mm 052 1035 dia 50 mm working width 37...

Page 15: ...e and components Hosematerial of polyuhrethane PUR enhanced with integrated spiral made of steel with convenient couplers Oil resistant very solid and suitable for abrasive dusts Heat proof up to 125 C 257 F Well suitable for extreme industrial usage Discharging if spiral is grounded PUR suction hose electrically conductive couplers already installed 3 5 m long dia 40 mm 052 0155 3 5 m long dia 50...

Page 16: ... length 500 mm 052 0264 Replacement rubber strip aluminium nozzle length 370 mm 052 0174 length 450 mm 052 0172 length 500 mm 052 0265 Oil resistant rubber strip length 370 mm 052 0194 length 450 mm 052 0195 length 500 mm 052 0280 Accessories Chrome plated curved tube dia 36 mm 052 0014 dia 40 mm 052 0111 dia 50 mm 052 0209 Chrome plated hand tube dia 36 x 500 mm 052 0012 dia 40 x 500 mm 052 0112 ...

Reviews: