background image

 

  

 
 

 
 
 
 
 
 
 
 

7890MG Series

  

Universal Media over IP Gateway 

for 10 x ASI/SD/HD/3G/GE 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 

© Copyright 2015 - 2016 
 

EVERTZ MICROSYSTEMS LTD. 

5288 John Lucas Drive 
Burlington, Ontario  
Canada L7L 5Z9 
 
Phone: 

+1 905-335-3700 

Sales: 

[email protected] 

Fax: +1 905-335-3573 

Tech Support:  [email protected]  

Fax: +1 905-335-7571 

Web Page: 

http://www.evertz.com

 

 
Version 0.2, February 2016 
 

The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely 
for the use of purchasers of the 7890MG series product.  Evertz Microsystems expressly prohibits the use of this manual for 
any purpose other than the operation of the 7890MG series product.  Due to on going research and development, features and 
specifications in this manual are subject to change without notice. 
 
All rights reserved.  No part of this publication may be reproduced  without the express written permission of Evertz 
Microsystems Ltd.  Copies of this manual can be ordered from your Evertz dealer or from Evertz Microsystems.

 

 

Summary of Contents for 78908MG-10GE2

Page 1: ...formation that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 7890MG series product Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 7890MG series product Due to on going research and development features and specifications in this manual are subject to change without notice All rights res...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ... 3 1 SERIAL VIDEO INTERFACE 9 3 2 INPUT 9 3 3 OUTPUT 9 3 4 ETHERNET OPTICAL INTERFACE 9 3 4 1 SFP Connections 9 3 5 ETHERNET ELECTRICAL INTERFACE 10 3 6 TRUNK INTERFACE 10 3 7 ELECTRICAL 10 3 8 PHYSICAL NUMBER OF SLOTS 10 3 9 COMPLIANCE 10 4 VISTALINK PRO INTERFACE 11 4 1 SYSTEM TAB 11 4 2 INPUT TAB 12 4 3 OUTPUT TAB 14 4 4 TRUNK PORT TAB 16 4 5 IP STREAM TAB 18 4 6 TRUNK PERFORMANCE TAB 20 4 7 SF...

Page 6: ...istaLINK PRO Output Tab 14 Figure 4 4 VistaLINK PRO Trunk Port Tab 16 Figure 4 5 VistaLINK PRO IP Stream Tab 18 Figure 4 6 VistaLINK PRO Trunk Performance Tab 20 Figure 4 7 VistaLINK PRO SFP Monitor Tab 21 Figure 4 8 VistaLINK PRO Input Fault Tab 22 Figure 4 9 VistaLINK PRO Output Fault Tab 23 Figure 4 10 VistaLINK PRO SFP Fault Tab 25 Figure 4 11 VistaLINK PRO Trunk Fault Tab 26 Figure 5 1 WebEas...

Page 7: ...ties of future performance either expressed or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relati...

Page 8: ...7890MG Series Universal Media over IP Gateway for 10 x ASI SD HD 3G GE Page iv Revision 0 2 REVISION HISTORY This page left intentionally blank ...

Page 9: ...y 1RU chassis and a 3RU modular card that can be installed in a 7800 frame to provide high density Video Audio Data transport in addition to up down stream signal processing Features Benefits Video GE Interface Ports The 7890MG 10GE2 provides up to 10x bi directional Access Interfaces 8x auto sensed ASI SD HD 3G GE 2x GE 10GE data ports Auto Sensing of ASI SDI HD SDI 3G GE Input Output Ports Hitle...

Page 10: ...Input Output Ports Ports 9 and 10 support 10GE fiber 1GE Fiber and 1GE copper allowing transport of a wide variety of other signals including AES Audio MADI GPIO RS232 422 Trunk Ports Dual trunk interface which allow for full 1 1 redundant link both 10G or 1G Supports 10GE fiber 1GE Fiber and 1GE copper for each interface Available with optional 1310nm 1550nm and CWDM SFP SFP modules Product Fully...

Page 11: ...eries Universal Media over IP Gateway for 10 x ASI SD HD 3G GE GETTING STARTED Revision 0 2 Page 3 2 GETTING STARTED 2 1 REAR PLATE DESCRIPTION Figure 2 1 7890MG 1RU Rear Plate Figure 2 2 7890MG 3RU Rear Plate ...

Page 12: ...7890MG Series Universal Media over IP Gateway for 10 x ASI SD HD 3G GE Page 4 Revision 0 2 OVERVIEW Figure 2 3 7890MG 8 10GE2 Rear Plate ...

Page 13: ... panels Insert the rear panel into the back of the chassis and secure using the screws provided Before inserting the card connect the serial cable to the board using the serial cable provided Now insert the 7890MG card into the corresponding front slots ensuring the card lines up with the slot runners on the bottom and the top of the chassis Push the card firmly into the slot ensuring that when it...

Page 14: ...t as well as set the Gateway Make the same changes for the IP address and Gateway of Trunk Port B as required When done Exit X the Network Setup and Save and Exit X from the Main Menu to ensure all changes are saved Figure 2 5 Tera Term Network Setup Power Cycle the 7890MG to ensure all changes are applied to the card Verfy the network connectivity by opening the command window and try to ping the...

Page 15: ... tree icon Expand the hardware tree by clicking on the button Your card should appear as a newly listed device with the IP address used to configure the card in section 2 3 It may take up to a minute to appear while the card and switch negotiate network settings this can be verified directly on the switch if necessary The user will be required to individually select each item to configure the appr...

Page 16: ...7890MG Series Universal Media over IP Gateway for 10 x ASI SD HD 3G GE Page 8 Revision 0 2 SPECIFICATIONS This page left intentionally blank ...

Page 17: ...avelengths Standard 1310nm 1550nm CWDM 1270nm 1610nm 3 4 1 SFP Connections Contained in this chart are a list of SFP Models that can be used for the Optical Interface and the important specifications for each SFP Model Wavelength Optical Output Power Receiver Sensitivity Normal Received Wavelength Max Distance Fiber Type MAX MIN SFP10G TR85 850nm 1dBm 6 5dBm 11dBm 850nm 300m Multimode SFP10G TR13 ...

Page 18: ...p to 328ft 100m 4 pairs 3 6 TRUNK INTERFACE Number 2 SFP cages Connector Type RJ 45 or LC UPC two simplex or one duplex per SFP SFP Rates 10 Gig Ethernet and 1 Gig Ethernet 3 7 ELECTRICAL Voltage 12 VDC 3 8 PHYSICAL NUMBER OF SLOTS 350FR 2 3700FR 2 7800FR 2 7801FR 2 3 9 COMPLIANCE Laser Safety Class 1 laser product complies with 24CFR 1040 10 and 1040 11 IEC 60825 1 EMI RFI Complies with FCC regul...

Page 19: ... 4 1 SYSTEM TAB Figure 4 1 VistaLINK PRO System Tab Misc System Reset Pressing this control will allow the user to reboot the MG module Follow onscreen prompts to engage rebooting process Card Type Displays of the type of MG module Firmware Version Displays the firmware version of the MG module Up Time Time elapsed since last boot ...

Page 20: ...elected and used a copper RJ45 or Ethernet fiber SFP must be installed in that port An SNMP alarm will be issued if the inserted SFP does not match this setting Video Pass Type Selection of Video Type to be transported The options for this are as follows NONE While the input port will see and report on the incoming stream it will not allow any video to be output over the Ethernet trunk ports 3G Th...

Page 21: ...limit for Ethernet Any packets that arrive at the Ethernet port that cause the stream to be over bandwidth will be dropped to prevent the trunk ports do not go over bandwidth Status Video Type Shows the type of video at the input RX of the SFP Port Can be 3G HD SD ASI or None When Ethernet mode is engaged this display is non functional Video Bandwidth Shows the bandwidth occupied by the incoming v...

Page 22: ...ndant Trunk These can be set per port it is not a universal control Non revertive The port will select either Trunk without preference It will stay on its selected trunk until it is no longer available Revertive Primary The port will prefer to use Trunk A but will switch to Trunk B if Trunk A becomes unavailable Once Trunk A is restored it will switch back Revertive Secondary The port will prefer ...

Page 23: ...B Secondary Video Type Shows the video type being received Video Bandwidth Shows the bandwidth of the video being received Video Standard Shows the video standard received Hitless Ready Shows if hitless switching is ready Hitless switching control must be enabled and latency below must be sufficient to allow both Trunks to see incoming data Additional Latency may be required to be added based on y...

Page 24: ... 2 VISTALINK PRO 4 4 TRUNK PORT TAB Figure 4 4 VistaLINK PRO Trunk Port Tab Ethernet Control Trunk A B IP Address Physical Port IP address setting for Trunk A Primary and Trunk B Secondary Netmask Netmask setting of Physical Trunk IP Ports Gateway Gateway setting of Physical Trunk IP Ports ...

Page 25: ...runk Received Fragment Frames Fragmented or partial frames received on Trunk Received Error Frames Errored Frames received Received Broadcast Frames Broadcast frame Traffic received monitor Received Multicast Frames Broadcast Multicast frames received Received VLAN Tagged Frames Counter for incoming Ethernet VLAN Tagged Frames Received Pause Frames Counter for incoming Ethernet pause frames Transm...

Page 26: ...m parameters and output IP stream can be controlled in this tab NOTE In this case Input corresponds to streams entering the Trunk ports of the MG card while Output corresponds to streams leaving the MG card through the Trunk ports In other words what came IN the video or Ethernet access ports goes OUT the Trunk port Input Stream Trunk A B Each Access Port has the ability to subscribe to an input s...

Page 27: ...n be set to Include or Exclude Include will indicate that the incoming multicast stream will include one of the Source Address below Exclude will exclude multicast stream with the listed Source Address below required for IGMPv3 Source Filtering IP Address 1 6 Source IP address of incoming multicast streams required for IGMPv3 Stream Present Shows the status of the incoming IP stream Valid statuses...

Page 28: ...rrent 15 minute and current 24 hour interval categories Categories Explained Current 15 Minute The current 15 minute error window log The number of errored seconds and severe errored seconds that occurred for the past 15 minutes Previous 15 Minute The previous 15 minute error window log Current 24 Hr The current 24 hour error window log The number of errored seconds occurred for the past 24 hours ...

Page 29: ...re error seconds that occurred within its respective category 4 7 SFP MONITOR TAB Figure 4 7 VistaLINK PRO SFP Monitor Tab Port Select The 7890MG 10GE possesses 12 SFP module sockets 10 for the access and 2 for the trunk The user can monitor SFP status for all SFP modules from this convenient view SFP Status Presence Displays whether or not a supported SFP is present in the slot Connector Type Dis...

Page 30: ... as 10 100 1000 for ports 1 8 and 1000Mbps or 10Gbps for ports 9 and 10 This is non functional on Trunk Ports For details on Trunk ports check the Trunk Port tab described above 4 8 INPUT FAULT TAB Figure 4 8 VistaLINK PRO Input Fault Tab Port Select Brings up the Input Fault SNMP Error Traps for each Access Port The check boxes on the left will enable or disable these faults from being sent to th...

Page 31: ...ut TAB Video Input Type Change Triggers when the video input format has changed Trunk A Tx Stream IP Change Triggers when any changes have occurred to the settings on this stream for Trunk A Trunk B Tx Stream IP Change Triggers when any changes have occurred to the settings on this stream for Trunk B 4 9 OUTPUT FAULT TAB Figure 4 9 VistaLINK PRO Output Fault Tab Port Select Brings up the Output Fa...

Page 32: ...sequence count error Video Stream Crc Error Triggers when there is a Video Output CRC Error Video ASI Output CC Error Triggers when there is an ASI Continuity Count Error detected on output Video ASI Output Sync Error Triggers when there is an ASI Sync Error Fault Video Output Hitless Not Ready Triggers when hitless switching is not currently available on the selected port Not having both Trunks p...

Page 33: ...e left will enable or disable these faults from being sent to the SNMP Fault Trap log Traps SFP Type Incorrect Triggers when the SFP inserted in the port does not correspond to the selected mode under the Input tab I e user has inserted a video SFP when Ethernet is selected SFP Rx Power Low SFP Optical Receive Power is Low Threshold is adjusted in the SFP Monitor TAB SFP Ethernet Link Status SFP E...

Page 34: ...ent to the SNMP Fault Trap log Traps Trunk Error Triggers whenever errored seconds appear on the selected Trunk Interface Trunk Severe Error Triggers whenever severe errored seconds appear on the selected Trunk Interface Trunk Link Down Triggers when the trunk link is not active Trunk Bandwidth Higher Trunk bandwidth is greater than max bandwidth threshold set in Trunk Port TAB Bandwidth High Thre...

Page 35: ...1 SYSTEM Figure 5 1 WebEasy System Page Misc System Reset Pressing this control will allow the user to reboot the MG module Follow onscreen prompts to engage rebooting process Card Type Displays of the type of MG module Firmware Version Displays the firmware version of the MG module Up Time Time elapsed since last boot up ...

Page 36: ...and used a copper RJ45 or Ethernet fiber SFP must be installed in that port An SNMP alarm will be issued if the inserted SFP does not match this setting Video Pass Type Selection of Video Type to be transported The options for this are as follows NONE While the input port will see and report on the incoming stream it will not allow any video to be output over the Ethernet trunk ports 3G The input ...

Page 37: ...it for Ethernet Any packets that arrive at the Ethernet port that cause the stream to be over bandwidth will be dropped to prevent the trunk ports do not go over bandwidth Status Video Type Shows the type of video at the input RX of the SFP Port Can be 3G HD SD ASI or None When Ethernet mode is engaged this display is non functional Video Bandwidth Shows the bandwidth occupied by the incoming vide...

Page 38: ...thout preference It will stay on its selected trunk until it is no longer available Revertive Primary The port will prefer to use Trunk A but will switch to Trunk B if Trunk A becomes unavailable Once Trunk A is restored it will switch back Revertive Secondary The port will prefer to use Trunk B but will switch to Trunk A if Trunk B becomes unavailable Once Trunk B is restored it will switch back ...

Page 39: ...bandwidth of the video being received Video Standard Shows the video standard received Hitless Ready Shows if hitless switching is ready Hitless switching control must be enabled and latency below must be sufficient to allow both Trunks to see incoming data Additional Latency may be required to be added based on your network Hitless Latency Level Primary Shows the buffer level of Trunk A Hitless L...

Page 40: ...Easy Trunk Port Page Ethernet Control Trunk A B Mode Select Allows the user to select the negotiated data rate of the Trunk Port 1G or 10G After changing this setting we recommend a card reboot IP Address Physical Port IP address setting for Trunk A Primary and Trunk B Secondary Netmask Netmask setting of Physical Trunk IP Ports ...

Page 41: ...d Frames received on Trunk Received Fragment Frames Fragmented or partial frames received on Trunk Received Error Frames Errored Frames received Received Broadcast Frames Broadcast frame Traffic received monitor Received Multicast Frames Broadcast Multicast frames received Received VLAN Tagged Frames Counter for incoming Ethernet VLAN Tagged Frames Received Pause Frames Counter for incoming Ethern...

Page 42: ...eters and output IP stream can be controlled in this tab NOTE In this case Input corresponds to streams entering the Trunk ports of the MG card while Output corresponds to streams leaving the MG card through the Trunk ports In other words what came IN the video or Ethernet access ports goes OUT the Trunk port Input Stream Trunk A B Each Access Port has the ability to subscribe to an input stream a...

Page 43: ...set to Include or Exclude Include will indicate that the incoming multicast stream will include one of the Source Address below Exclude will exclude multicast stream with the listed Source Address below required for IGMPv3 Source Filtering IP Address 1 6 Source IP address of incoming multicast streams required for IGMPv3 Stream Present Shows the status of the incoming IP stream Valid Statuses are ...

Page 44: ...hat occurred for the past 15 minutes Previous 15 Minute The previous 15 minute error window log Current 24 Hr The current 24 hour error window log The number of errored seconds occurred for the past 24 hours Control Severe Error Threshold Sets the number of severe link errors to occur consecutively before sending an SNMP warning alarm Total Status Clear Clears the Trunk error counters for their re...

Page 45: ...FP module Firmware Version Firmware version of the inserted SFP module Rx Power Alarm Threshold Sets the minimum received optical power before an SNMP alarm fault is sent This control only works with Fiber based SFPs Rx Optical Power Receive optical power if a Fiber SFP module is used Tx Wave Length Transmitted wavelength of the Fiber SFP module Eth Link Status Displays Ethernet Link Presence for ...

Page 46: ... HD 3G GE Page 38 Revision 0 2 WEBEASY 5 8 NOTIFY Figure 5 8 WebEasy Notify Page Port Select Brings up the Input Fault SNMP Error Traps for each Access Port The check boxes on the left will enable or disable these faults from being sent to the SNMP Fault Trap log ...

Page 47: ... the settings on this stream for Trunk A Trunk B Tx Stream IP Change Triggers when any changes have occurred to the settings on this stream for Trunk B Port Select Brings up the Output Fault SNMP Error Traps for each Access Port The check boxes on the left will enable or disable these faults from being sent to the SNMP Fault Trap log Traps Video Output Loss Triggers when video was present and is n...

Page 48: ...mum of two simultaneous input streams to be sent to the output Port being selected These input streams can appear on Trunk A and Trunk B simultaneously Typically these will be main and backup input streams SFP Rx Power Low SFP Optical Receive Power is Low Threshold is adjusted in the SFP Monitor TAB SFP Ethernet Link Status SFP Ethernet Link Status Up or Down SFP Present SFP Presence Detect Trunk ...

Page 49: ...ents It will also be necessary to add JAR files for new products If your new product has not appeared even after waiting a few minutes for the Ethernet switch negotiation to complete then it is possible that your JAR file may be old or missing To perform a JAR update ensure that all VLPro clients are closed those clients which are not closed will automatically be disconnected as soon as the VLPro ...

Page 50: ...the change to take effect Apply as many JAR updates as required before restarting the server NOTE You may confirm that all updates have been successfully applied by selecting from the menu Tools View Show Hide Product update log Shutdown the server by selecting from the menu File Shutdown Server Now re open the server it is normal for the start up to take marginally longer while each individual up...

Page 51: ...a tab labeled Upgrade Select this tab and ensure that the latest firmware is running on the 7890MG card If it is not upgrade the firmware using the latest jar files which can be found on the Evertz website Select Browse and locate the jar file on the computer Then select Upgrade when the upgrade is complete the 7890MG will Reboot to apply the firmware upgrades Figure 6 3 WebEasy Firmware Upgrade ...

Page 52: ...7890MG Series Universal Media over IP Gateway for 10 x ASI SD HD 3G GE Page 44 Revision 0 2 UPGRADE PROCEDURE This page left intentionally blank ...

Reviews: