background image

 

 

     EASY DECISION 

 

INSTALLATION, OPERATION   

& MAINTENANCE INSTRUCTIONS 

 

FOR EVERDURE 4 ELEMENT ELECTRIC COOKTOPS 

 

 

   

 

 

  

 
 
 

 
  
 
 
 
 
 
 
 

 
 
 
 
                                                                                               
 
 
 
 
 

 
 

 

 
 
Models Included: 
 

CBES611  

 

KIMBERL 

 

 

Summary of Contents for CBES611

Page 1: ...EASY DECISION INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR EVERDURE 4 ELEMENT ELECTRIC COOKTOPS Models Included CBES611 KIMBERL Y ...

Page 2: ...instructions carefully to avoid misuse and hazards It is important that you retain these instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Everdure reserves the right to alter specifications or appearances without notice CONTENTS SECTION PAGE NO Important Safety Instructions 3 Appliance Deta...

Page 3: ...be accessible after installation The appliance must be electrically isolated before any maintenance can be performed 10 The appliance is not intended to be operated by means of an external timer or separate remote control system 11 Electrical connection must be made as per local wiring rules and regulations Do not disconnect the appliance with wet hands and do not disconnect the power cord with ex...

Page 4: ...e x 2 5 mm not supplied This information can be found on the rating plate data label affixed to the underside of the appliance PRODUCT SPECIFICATIONS 2 x 2 00 kW thermostatic plates diameter 180 mm 2 x 1 50 kW thermostatic plates diameter 145 mm Side control operation COOKTOP SURFACE LAYOUT COOKTOP SIZES Relevant Sizes LENGTH mm WIDTH mm HEIGHT mm Cooker size 580 500 45 90 incl knobs Cut out size ...

Page 5: ...the terminals are accessible by removing the terminal block cover by removing the cover screw The cable connections must be in accordance with the diagram located on the bottom of the cooktop The brass links must be positioned as marked in the appropriate diagram and once established ALL terminal screws must be tightened down firmly If when the hob is first switched on only two of the zones work y...

Page 6: ...drawing for minimum clearances Also see the following minimum distances stated below 600 mm between the hob surface and the underside of any horizontal surface above it 50 mm clearance around the appliance and between the hob surface and any combustible materials UNPACKING THE APPLIANCE When unpacking the appliance please check that the following items are contained within the packaging 1 Cooktop ...

Page 7: ...ant to seal the appliance against the bench top This will make it difficult to remove the cooktop from the bench top in future particularly if it needs to be serviced A Sealing strip B Clamp C Screw Place the clamp B over the holes that match the size of the screws There are one set of screw holes in each corner of the hob Slightly tighten a screw C through the clamp B so that the clamp is attache...

Page 8: ... NOT covered under warranty You should not use saucepans with rough bottoms as this can scratch the solid plates Before use make sure that the bottoms of the saucepans are clean and dry When cold the bottom of the pans should be slightly concave as they expand when hot and lie flat on the surface of the cooktop This will allow the heat to transfer more easily The best thickness for the bottom of t...

Page 9: ...th a clean cloth If the cooktop is heavily soiled it is recommended that a stainless steel cleaner be used but only on stainless steel appliances IMPORTANT If a stainless steel cleaner is not used regularly then it is possible for the surface of the cooktop to change colour over a period of time For other cooktop surfaces a mild non abrasive cream cleaner may be used MAINTAINING THE SOLID PLATES I...

Page 10: ...cleaning instructions are being followed regularly 4 Element s are not working The cooktop is fitted with resettable thermal fuses which will temporarily disable single elements or the complete unit if internal temperatures exceed the normal operational temperature range due to abnormal conditions Operation will re start after the unit has cooled down to within the normal operating temperature ran...

Page 11: ...EASY DECISION DATA LABEL ELECTRICAL DIAGRAM 11 ...

Page 12: ...ION A division of Shriro Australia Pty Ltd 104 Vanessa Street Kingsgrove NSW 2208 AUSTRALIA 1300 355 541 www everdure com NEW ZEALAND 09 415 6000 www everdure co nz IM Ref CBES611 24 2017 01FC FOR INDOOR USE ONLY ...