Page 1: ... COOKTOP Appliance Class 3 Empava Item 30 EMPV 30GC0A2 EMPV 30GC0A5 36 EMPV 36GC202 EMPV 36GC881 EMPV 36GC888 EMPV 36GC901 Distributed by Empava Appliances Inc 15253 Don Julian Rd City of Industry CA 91745 USA www empava com ...

Page 2: ...The instructions shall be marked with directions to the installer to leave them with the appliance and to the consumer to retain them for future reference ...

Page 3: ...Cleaning and user maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use g...

Page 4: ...Contents Cooktop Description Important Information Operation Maintenance and Cleaning Troubleshooting Instructions for the Installer Important safety requirements Installation 1 ...

Page 5: ...ion must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or in Canada the Natural Gas and Propane Installation Code CSA B149 1 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code NFPA 70 or the Canadian Electric Code CSA C22 1 02 2 ...

Page 6: ... 13600Btu hr in 5 20 4 burner 9 6000Btu hr in 2 56 5 Burner 10 3400Btu hr in 1 77 Total heat input 37600Btu hr EMPV 30GC0A2 Operating Instructions Knob 1 is for burner 10 Knob 2 is for burner 9 Knob 3 is for burner 8 Knob 4 is for burner 7 Knob 5 is for burner 6 1 burner 6 6000Btu hr in 2 56 2 burner 7 10200Btu hr in 3 74 3 burner 8 13600Btu hr in 5 20 4 burner 9 6000Btu hr in 2 56 5 Burner 10 340...

Page 7: ...rner 8 Knob 4 is for burner 7 Knob 5 is for burner 6 Total heat input 37600Btu hr EMPV 36GC881 EMPV 36GC888 1 burner 6 10200Btu hr in 3 74 2 burner 7 6000Btu hr in 2 56 3 burner 8 13600Btu hr in 5 20 4 burner 9 6000Btu hr in 2 56 5 burner 10 3400Btu hr in 1 77 1 burner 6 10200Btu hr in 3 74 2 burner 7 6000Btu hr in 2 56 3 burner 8 13600Btu hr in 5 20 4 burner 9 6000Btu hr in 2 56 5 burner 10 3400B...

Page 8: ...oes not appear on the appliance it is necessary to refer to the technical instructions which will provide the Total heat input 37600Btu hr Operating Instructions Knob 1 is for burner 10 Knob 2 is for burner 9 Knob 3 is for burner 8 Knob 4 is for burner 7 Knob 5 is for burner 6 1 burner 6 10200Btu hr in 3 74 2 burner 7 6000Btu hr in 2 56 3 burner 8 6000Btu hr in 2 56 4 burner 9 3400Btu hr in 1 77 5...

Page 9: ...ust be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Always check for the validity of the pressure regulator Technical specification of the pressure regulator i Refer to TECHNICAL DATA in this manual ii Max consumption 2 5kg h iii Should b...

Page 10: ... the extractor speed Do not use gas cooktop if it is in contact with water Do not operate the gas cooktop with wet hands Ensure the control knobs are in the closed position when not in use In the event of the burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for at least 1 min Service The gas cooktop should only be repaired or serv...

Page 11: ...case of a power failure or failure of the ignition a match or lighting devise can be used Care must be taken when using this method The device shall not be operated for more than 15s If after 15s the burner has not lit stop operating the device and open the compartment door and or wait at least 1 min before attempting a further ignition of the burner In the event of the burner flames being acciden...

Page 12: ...Do not use rim based or convex based vessels on the hotplate burners WARNING As soon as a liquid starts boiling turn down the flame so that it will barely keep the liquid simmering If the control knobs become difficult to turn please contact your local service centre WARNING Users could not use the cooking vessels on the hotplate that overlap its edges WARNING All burner caps can t be dislocated i...

Page 13: ...ECT the gas cooktop from the electricity supply The gas cooktop is best cleaned while it is still warm as spillage can be removed more easily than if it is left to cool Control Panel Sign gas valve is shut off Sign largest flame Sign smallest flame Sign electric discharge for ignition The Burners The burner caps and crowns can be removed for cleaning Wash the burner caps and crowns using hot soapy...

Page 14: ...d liquids 2 Not obstructing the flow of combustion and ventilation air 3 Visually checking pilot s and burner flames with pictorial representation A Remove the utensil supports B Light burners C Turn knobs from MAX to MIN Check the flame status the flame in MIN position should be smaller than in MAX position as figure shown below D Always check flame before each use see TROUBLESHOOTING if any abno...

Page 15: ...ut out dimensions For Model Width Depth EMPV 30GC0A2 EMPV 30GC0A5 28 34in 18 30in EMPV 36GC202 EMPV 36GC881 EMPV 36GC888 EMPV 36GC901 34 45in 19 01in Technical Data Burner configuration NG LPG Nozzles Dia mm Btu hr Nozzles Dia mm Btu hr Wok burner Triple ring burner 1 50 13600 1 00 13600 Rapid burner 1 28 10200 0 85 10200 Semi rapid burner 0 97 6000 0 65 6000 Auxiliary burner 0 72 3400 0 50 3400 D...

Page 16: ... distance from the front edge of the cooktop to the front edge of the countertop should be 3 0 The distance between the closet should be 23 62 not less than the depth of the cooktop itself see Figure 12 Notice that a horizontal separation below the base of the hotplate is needed The minimum distance between this separation shall not exceed 5 90 Figure 12 WARNING The use of a gas cooking appliance ...

Page 17: ...as cooktop you must first close the air supply valve and the cooktop valve unplug the plug of models with AC power supply only after that you can remove the connector hose or threaded connector and then move the gas cooktop Warn of the potential hazards associated with storage cabinet areas above appliances Misoperation can cause fire All cord connected appliances shall include instructions relati...

Page 18: ... with the accessory kit See Burner Configuration for detailed nozzle specifications 3 Remove the burners burner caps and screw out the nozzles from the burner bases Then install those nozzles in the Conversion Kit bag to each burner base correspondingly Save the orifices removed from the appliance for future use 4 Input inlet pressure of 11 in wc 2740Pa coat the nozzle joints and the gas pressure ...

Page 19: ...ity having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as speci...

Page 20: ...r of the cabinet adequately Pressure Regulator Installation A Cooktop air pipe joint B Pressure Regulator C Gas fitting First make sure that the pressure regulator arrow points toward the cooktop air pipe joint and then fasten the pressure regulator to the cooktop air pipe Then install the gas fitting on the other side of the pressure regulator See Figure 16 Figure 16 Gas Connection and check D En...

Page 21: ...COOKTOP MUST BE EARTHED If the cooktops to be connected to a 120V 60 Hz AC electrical supply Before switching on make sure the electricity supply voltage is the same as that indicated on the cooktops rating label Ensure that the cooktops supply cable does not come into contact with surfaces with temperatures higher than 50 deg C WARNING Electrical Grounding Instructions This appliance is equipped ...

Page 22: ...the grounding prong from this plug Circuit Diagram Figure 22 for the appliance with four burners Figure 23 for the appliance with three burners ...

Page 23: ...he one fitted with D C supply device only you are suggested to use one 1 5V battery Be sure that the battery is well fixed then you can follow the Lighting procedure Take off the battery if you won t use the cooktop for a long time Check the working performance every time before cooking 15 ...

Page 24: ...try CA 91745 WARRANTY CARD PLEASE READ AGREEMENT BEFORE SIGNING Click Here Keep this copy for yourself Product Model Number Name _________________________________________ Date of Purchase _________ Where Purchased Store ________________________ Print Name _________________________________________________________ Address ___________________________________________________________ 16 ...

Page 25: ...ity of Industry CA 91745 Product Model Number Name _________________________________________ Date of Purchase _________ Where Purchased Store ________________________ Print Name _________________________________________________________ Address ___________________________________________________________ City ________________________ ST _____ ZipCode ______________________ E mail ___________________...