background image

   

 

 

 

 
 

LED-328

 

User Manual

 

 
 
 
 

 

 
 

Etung Technology Co. Ltd 

305 Gengfang Plaza, Jia 13 Huayuan Road, Haidian Dist. Beijing 

TEL:4008-909-611 FAX:010-64857815 

Website: 

www.etungtech.com.cn

 

Copyright © 2005-2015 ALL RIGHTS RESERVED 

Summary of Contents for LED-328

Page 1: ...D 328 User Manual Etung Technology Co Ltd 305 Gengfang Plaza Jia 13 Huayuan Road Haidian Dist Beijing TEL 4008 909 611 FAX 010 64857815 Website www etungtech com cn Copyright 2005 2015 ALL RIGHTS RESERVED ...

Page 2: ...ght Description 7 1 6 3 Serial Port Definition 7 1 7 Technical Advantages 8 1 8 Typical Usecases 9 2 Device Configurations 11 2 1 Configurations 11 2 1 1 Preparation 11 2 1 2 Configuring LED 328 11 2 1 2 1 Add Terminal to the User via WEBLED 12 2 1 2 2 Add Terminal to the User via Configuration Software 14 2 2 Configuration Parameters 17 2 3 Restore to default 18 2 4 Firmware Update 19 2 5 Remote ...

Page 3: ...produced after LED 528 by eTung It is a product for wireless LED information publishing that has more reasonable cost control and is more reliable and easy to use as well It has smaller size and can be installed in small LED screens It supports LED screens with at most 32 points in height LED 328 is compatible with WEBLED information publishing system as well It is the best choice for large scale ...

Page 4: ...EtungTech LED 328 User Manual 4 1 2 Product Outlook Figure 1 1 Product architecture 1 3 Standard Accessories Figure 1 2 GSM acetabulum antenna ...

Page 5: ...EtungTech LED 328 User Manual 5 Figure 1 3 9 pin and 9 hole direct serial line Figure 1 4 TTL converter 1 4 Dimensions Figure 1 5 LED 328 dimension ...

Page 6: ... remotely and wirelessly The information deployment is done by IE or other web browser and it is not required to install typical exe application so it is more convenient and the information deployment can be done anywhere at any time 1 6 Capability Parameters 1 6 1 Technical Parameters Basic Parameters Control Range 256 32 dual color 512 32 mono color Scan Mode 1 16 1 8 1 4 Scan Interface one 08 p...

Page 7: ...ting to data center Flash slowly Dialing Power light power Always light Power supply OK Extinguished No power supply Table 1 1 LED 328 indicator light description 1 6 3 Serial Port Definition Type RS 232 Pin 2 3 5 Definition RXD out TXD in GND Table 1 2 LED 328 serial port pin definition Attention LED 328 TTL to RS232 serial port is used only to configure or update the model and it cannot be used ...

Page 8: ...and reply within 5 seconds Software to divide the LED display into sub regions easily and conveniently Support displaying multiple programs and displaying programs at a fixed time Support simulative clock animation and display test Support program copy save and load Built in 16 and 32 lattice character set in Chinese and English Information can be sent to LED 328 via point to point point to multip...

Page 9: ...EtungTech LED 328 User Manual 9 1 8 Typical Usecases Figure 1 7 Publish general information Figure 1 8 Publish special information with LED 328 customized software package ...

Page 10: ...EtungTech LED 328 User Manual 10 Figure 1 9 Publish taxi information via I O interface ...

Page 11: ...Firmware Update 5 Remote Configurations 2 1 Configurations 2 1 1 Preparation TTL to RS 232 converter Serial line used to connect LED 328 with PC or user devices GSM Antenna 5V Power Adapter one SIM card either from China Mobile or China Unicom that applies GPRS and can access internet directly via NET 2 1 2 Configuring LED 328 Login website http da wuxianled com and register ...

Page 12: ...fter registration contact eTung technical support by phone call 4008 909 611 to open the account After that there are two ways to add the device to the user registered before 2 1 2 1 Add Terminal to the User via WEBLED Login website http da wuxianled com input username account and password after login is successful click Add Terminal ...

Page 13: ...er tick it and then click My Terminal on the lower left side to add the terminal to the user Figure 2 4 Add terminal Click Terminals on the left side then the terminal can be seen in the terminal list and then the user can configure the terminal and edit messages for detail please refers to the appendix ...

Page 14: ... connect the converter with PC via 9 pin 9 hole serial line Find and run LED 328 dedicated configuration executable DTUcfg exe either from the CD or by downloading from eTung website http www etungtech com cn Click button Configure in the upper side of the user interface and in the popup dialog with title Settings select the serial port that is used to configure LED 328 then click OK ...

Page 15: ... based on the prompt and power on LED 328 quickly within 30 seconds when the information about LED 328 model appears press Enter Figure 2 7 Press Enter to go to configuration menu Continue to press Enter until item 4 configure the username that is registered in WEBLED website before ...

Page 16: ...EtungTech LED 328 User Manual 16 Figure 2 8 Configure username Press Enter to use the default value for all the other items until configuration is complete Figure 2 9 Configuration complete ...

Page 17: ...ain and port Configuration Menu Item Description RESTORE THE DEFAULT SETTINGS Y N N Configure to restore to default or not 1 MSERVER DN IP Address da wuxianled com Configure data center IP address or domain 2 MSERVER Port 8888 Configure data center port 3 Web User Name Configure applied username from wireless LED website This username is checked and used to login Combo terminal server 4 APN cmnet ...

Page 18: ... 1234 Configure password used for authentication when sending commands to device via SMS default is 1234 CHECK SIGNAL QUALITY Y N N Configure whether to check signal quality where LED 328 DTU is located It can only work properly with good or better signal quality Table 2 1 Details of configuration parameters 2 3 Restore to default According to the description of Configuring LED 328 after entering ...

Page 19: ...r firmware software According to the description of Configuring LED 328 connect LED 328 with PC via TTL converter and 9 pin 9 hole serial line run LED 328 configuration executable and set the serial port used to update LED 328 Click Select File and then select the file bin to update and click Open ...

Page 20: ... Select file to update Click Start Update then power on the device quickly within 30 seconds Figure 2 13 Firmware Update After update is complete the device will reboot automatically then in the user interface a prompt Update finished will appear ...

Page 21: ...be offline because LED 328 can detect whether SMSs for configurations are received or not only when it is dialing and then updates it s IP and port accordingly 2 Format of SMS configuration is 1234 IP port For example 1234 da wuxianled com 8888 is semi colon in English 1234 is the initial password In order to change the password LED 328 must be connected to PC via serial port enter LED 328 configu...

Page 22: ...2 Methods Select the device in mServer right click it and select Remote Config at the left part of the dialog input the following command in Command List AT MSERVER IP PORT For example AT MSERVER eyun etungtech com 8080 After that click button Send if all operations are correct in the list of CMD Response at the right part an OK will appear Then LED 328 will be offline from this mServer and connec...

Page 23: ...example AT SMSZHUANFA CXYE 10086 13651078461 DTU can use this AT command to check balance flow etc If src replies a long SMS it will be truncated and sent to dest 3 AT GETDV idx Get information about configuration item We can use it together when configuring remote parameters with vircom 4 1 version 4 AT UPTIME Get running time since DTU boot It can be used to chek whether DTU is rebooted 5 AT CSQ...

Page 24: ...chapter 2 1 Configurations Step 2 Login WEBLED Login website http da wuxianled com with the username that has been registered and open Figure Appendix 1 1 Login Combo terminal WEBLED Step 3 Set Display Parameters 1 Select the terminal Figure Appendix 1 2 Select terminal 2 Click Screen Parameter Configuring under Terminal Control ...

Page 25: ... Configure Display Parameters 3 In the popup dialog click New Template then input the horizontal and vertical pixels click Save Template and then OK to save the settings Figure Appendix 1 4 Create template Figure Appendix 1 5 Set horizontal and vertical pixels ...

Page 26: ...1 6 Click OK to save settings Step 4 Configure Driver 1 In Terminal Control select Set control card driver Figure Appendix 1 7 Select Set control card driver 2 Ask scan mode from the display vendor 3 Select correct scan mode in the dialog accordingly ...

Page 27: ... 27 Figure Appendix 1 8 Select scan mode 4 Click Tasks and check if the configurations have been sent successfully Figure Appendix 1 9 Check sending status Step 5 Edit Program 1 Under tab Programs click New to create a new program ...

Page 28: ...e Appendix 1 10 Click New program 2 Set program size height and width must match the screen size Figure Appendix 1 11 Set program size 3 Add one row of text set size used on the screen and font used to display the text and then click Save 4 ...

Page 29: ...dix 1 12 Set Text size Step 6 Publish Program 1 Click Publish New under tab Publish Information to create a new publish task Figure Appendix 1 13 Create new publish task 2 Fill in Task Description select the program to be published and click Next ...

Page 30: ...sh the program click Next Step and then click Confirm Publish to publish the program Figure Appendix 1 15 Select terminal to publish program Figure Appendix 1 16 Publish the program Step 7 Check if the Program has been Published Check if the program has been sent successfully under tab Publish Information ...

Page 31: ...EtungTech LED 328 User Manual 31 Figure Appendix 1 17 Check send status ...

Reviews: