RDAO-1 Optically Isolated  

                                       Wiegand card reader DA Instructions

 

 
The RDAO-1 is 3 port, Wiegand reader distribution amplifier with optically isolated inputs and outputs for 
access control systems.  All three ports are optically isolated from one another which prevents ground 
loop caused data corruption issues. The RDAO-1 Monitors the LED outputs of the access control 
panels and outputs an LED indication of “access granted or denied”  
 

Reader Input 

The RDAO-1 accepts one-way data standard Weigand card readers only. The RDAO-1 supports one or 
two LED indicators. The reader power can also be configured for 12vdc or 5 vdc via an onboard jumper. 
See figure 1. 
 

Power Reader Locally Input 

The Reader can be powered near the site and this input is used for that purpose. The reader power 
source jumpers must be set for local. See figure 1. 
 

Reader Power 

The reader power can be supplied from a local power supply or by any one of the three connected access 
control panels. See jumper settings in figure 1. 
 

Data outputs 

Whatever data comes out of the Wiegand reader will appear at the terminals of the D0 and D1 terminals 
of the access control panel outputs. Connect these outputs to the access control panel reader inputs. See 
figure 1. Note- no card read data is stored in the RDA1. 
 

Panel connections 

Note- 12vdc power must be supplied to the RDAO-1 form EACH connected access control panel or the 
RDAO-1 will not transmit card read data. Connect the 12vdc power, data 0, data 1 and LEDs as shown in 
figure 1.  

 
LED signals 

All LED inputs are normally high. The inputs to the RDAO-1 from the access control panels can be 5v or 
12v. When a valid card read is detected by any of the 3 “green LED” inputs going low, the RDAO-1 will 
send a “green LED” signal to the Wiegand reader green LED terminal (logic low). If an invalid card read is 
detected by any or all of the 3 “red LED” inputs going low, the RDAO-1will send a “red LED” signal to the 
Wiegand reader red LED terminal (logic low). See figure 1 For connections. You can also tie the Door 
release signal via a relay from each panel to the Green LED input to display a valid card read on the 
reader from any panel. 
 

Cabling 

Run a #22 6 conductor shielded from the Wiegand reader to the RDAO-1. Run up to 3 each #22 6 
conductor shielded cables from the RDAO-1 to each access control panel. The shield can be used as a 
common.  
 

Grounding jumper 

The RDAO-1 can be grounded locally to whichever power source is selected. This is useful if vicinity area 
lightning strikes are frequent and are problematic. Note- if grounds between the selected reader power 
source and this ground point are at different potentials, data corruption may occur.  