background image

E. D. ETNYRE & CO.  

1333 S. Daysville Road, Oregon, Illinois 61061 

Phone: 815/732-2116  Fax: Sales 815-732-7400   

email: [email protected]   www.etnyre.com

 

Centennial

Flow Charts and Control Positions

ON

OFF

A-130-12R

Serial Numbers S5613 and up

Revised 15 May 2020

Variable Width Spraybar

with  

BT-1 Controls

Summary of Contents for Centennial A-130-12R

Page 1: ...llinois 61061 Phone 815 732 2116 Fax Sales 815 732 7400 email sales etnyre com www etnyre com Centennial Flow Charts and Control Positions ON OFF A 130 12R Serial Numbers S5613 and up Revised 15 May 2020 Variable Width Spraybar with BT 1 Controls ...

Page 2: ... 4 0 to 7 5 3 3351009 S36 5 V Slot 18 45 81 2 04 7 0 to 10 0 4 3352368 Multi Material V Slot 15 40 68 1 81 6 0 to 9 0 5 3351015 3 32 Coin Slot 15 40 68 1 81 6 0 to 9 0 6 3352204 Multi Material V Slot 35 95 1 58 4 30 12 0 to 21 0 7 3355154 End Nozzle use with 3352204 nozzle 35 95 1 58 4 30 12 0 to 21 0 8 3355010 Multi Material V Slot 29 72 1 31 3 26 10 0 to 165 9 3352205 Multi Material V Slot 20 55...

Page 3: ...ity to read and understand the instructions should be a required qualification to become an operator There are also functions that require a certain amount of physical strength to accomplish Persons lacking the required strength may not only place themselves in jeopardy but also others in the vicinity Read and understand the Safety precautions found in M 114 12R Centennial Asphalt Distributor Oper...

Page 4: ... 1 Turn the SUCK BACK OVERRIDE switch ON 2 Press START The pump will start turning at the desired rate 200 GPM is recommended 3 If complete bar suck back is desired follow the instructions for bar suck back beginning with the opening of the left bleeder valve Otherwise continue to the next step 4 Turn the SUCK BACK OVERRIDE switch OFF 5 Press START The pump will start turning at the desired circul...

Page 5: ...g AUTO PUMP CONTROL or turning ON either POWER switches front or rear 5 Function knob When the desired operation is se lected through this knob the asphalt pump stops turning if the PUMP CON TROL is in AUTO and all automatic valves tank valve 4 way valve bar suck back valves and balance valves are set for the desired operation The asphalt pump rate is set to the stored preset for the desired opera...

Page 6: ...6 ON OFF Load through Manhole Keyway in 12 o clock position 4 Way Valve HOME ...

Page 7: ...hrough Load Line Keyway in 12 o clock position 4 Way Valve LOAD Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD position Push START switch ...

Page 8: ...Tank Keyway in 12 o clock position Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to BAR CIRCULATE position Push START switch 4 Way Valve TANK CIRCULATE ...

Page 9: ... Bar Keyway in 9 o clock position Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to BAR CIRCULATE position Push START switch 4 Way Valve BAR CIRCULATE ...

Page 10: ...10 ON OFF Spray Keyway in 6 o clock position with spray switch On 4 Way Valve BAR CIRCULATE NOTE Unit should already be operating in Bar Circulate and circulating oil to be ready to spray ...

Page 11: ...ve it open until you hear a positive indication of vacuum at the valve After closing the valve repeat the procedure on the opposite wing Keyway in 12 o clock position 4 Way Valve SUCKBACK Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to SUCKBACK position Push START switch ...

Page 12: ...ition 4 Way Valve HANDSPRAY Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to HANDSPRAY position Push START switch Cab Panel POWER switch ON 50 GPM adjust using VALUE switch ...

Page 13: ...k position 4 Way Valve SUCKBACK Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to SUCKBACK position Push START switch Cab Panel POWER switch ON 200 GPM adjust using VALUE switch ...

Page 14: ...PUMP SPEED knob zero fully counterclockwise Function Switch to TANK CIRCLATE position Push START switch Operate pump 10 GPM in Manual to allow pump to circulate material to prevent pump from getting too cold if possible Connect Load Line to the Storage Tank pump or distributor you wish to transfer to Do not remove Load Line cap if front or rear tank valve is open ...

Page 15: ...d with Pump Keyway in 12 o clock position Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to UNLOAD position Push START switch 4 Way Valve UNLOAD ...

Page 16: ...nsfer Keyway in 12 o clock position 4 Way Valve TRANSFER Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to TRANSFER position Push START switch ...

Page 17: ...Way Valve LOAD Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD position Push START switch WASH PUMP switch optional ON Cab Panel POWER switch ON 100 GPM adjust using VALUE switch ...

Page 18: ...ay Valve FLUSH Keyway in 9 o clock position Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to FLUSH position Push START switch WASH PUMP switch optional ON ...

Page 19: ...4 Way Valve Tank Circulate Keyway in 12 o clock position Rear Panel POWER switch E Stop ON PUMP CONTROL switch AUTO PUMP SPEED knob zero fully counterclockwise Function Switch to LOAD position FRONT LOAD switch optional OPEN Push START switch ...

Page 20: ......

Reviews: