background image

Enterview MX Manual_Layout 2  07/10/2013  14:59  Page 1

Summary of Contents for Enterview MX EVMX2

Page 1: ......

Page 2: ...he keypad 10 Programming the proximity reader 12 Trouble Shooting Guide 14 EVMX2 or EVMX2C 2 way mono or colour video door entry call station EVMX4 or EVMX4C 4 way mono or colour video door entry call...

Page 3: ...um of 6 call buttons without an expander Expander if required maximum of 9 call button per expander External call station power supply DC 12 volts EVBPS one required per door Handset EV5H EV5HF minimu...

Page 4: ...ply to each handset Note The maximum cable distance per external call button to each handset is 100 meters using CAT5e cable The maximum distance per supplied power supply to each handset is 10 meters...

Page 5: ...ng of red and black cores supplied should be connected to the corresponding cable going to the EVBPS power supply Connect to terminals 3 and 4 DC 12V in the EVBPS Fig 3 Fit the white plug into the whi...

Page 6: ...ment handset 4 core wire connect to each apartment handset Connect to power Use EVBPS adaptor Connect to keypad module A B C D E F G J K L Connect to P B in the EVBPS H I Seal Main panel with proximit...

Page 7: ...lease lock If the lock does not operate please ensure that the Normally Open contact from the dedicated output for the trade button switches to Normally Closed when trade button is operated The trade...

Page 8: ...arrow and the word up see Fig 1 item 1 Fit mounting plate to the selected location recommended mounting height 1 45m see Fig 6 Feed the cable from the local transformer and the external call button th...

Page 9: ...ain handset Main handset Extension handset Main handset Main handset Extension handset ACDC adaptor included ACDC adaptor included ACDC adaptor included ACDC adaptor included ACDC adaptor included ACD...

Page 10: ...t this confirms a code is stored at this location Enter the desired 4 digit user code if at this point you get a long continuos tone then this pin number is in use on the system already and cannot be...

Page 11: ...9 s to complete the delete all command Note this does restore factory settings of the lock release time of 5 seconds Setting the lock time Factory default door open time is set at 05 seconds Enter pr...

Page 12: ...a single confirmation tone will be heard To add further cards simply enter the last 6 digits of the next card If the error tone is emitted 4x beeps this indicates that this card tag is already regist...

Page 13: ...ry default door open time is set at 05 seconds Enter programming mode Press 4 a single confirmation tone will be heard Enter the desired lock relay operation time in a two digit format 01 to 99 second...

Page 14: ...of voltage and or cable run length The PSU s supplied with each monitor must be used and the cable length from PSU to monitor must not exceed 10m In multi apartment systems if more than one apartments...

Page 15: ...15...

Page 16: ...Elite Security Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 515150 email info espuk com...

Reviews: