U S E R   M A N U A L

w w w . e s p u k . c o m

A P K I T G   |   C O L O U R   V I D E O   D O O R   E N T R Y   S Y S T E M

APKITG Manual.indd   1

26/04/2017   09:43:25

Summary of Contents for APKITG

Page 1: ...U S E R M A N U A L w w w e s p u k c o m A P K I T G C O L O U R V I D E O D O O R E N T R Y S Y S T E M APKITG Manual indd 1 26 04 2017 09 43 25 ...

Page 2: ...ble Cat 5E UTP PVC Cable Contents System Components 3 Installation 4 System Connections Example 1 5 System Connections Example 2 6 Lock Connections Example 1 7 Lock Connections Example 2 8 User Guide 9 Monitor Overview 10 Setting Monitor as Master or Slave Default Master 11 Accessing Monitor Functions 12 Accessing Monitor Adjustments 13 Installer s Guide 14 APKITG Manual indd 2 26 04 2017 09 43 26...

Page 3: ...ation Monitor EVBPSBB Lock Power Supply EV EXIT Push To Release EV EBG Emergency Release EV ML 250 500XT Electro magnetic Lock ENTERD Electric Lock Optional Accessories System Power Supply APKITG Manual indd 3 26 04 2017 09 43 28 ...

Page 4: ...needs to point in the direction of where a visitor will stand during operation Site the indoor monitor to suit application Monitor 1 Gang Mount Box if required not supplied Surface mount the bracket of the monitor or if required onto a 1 gang mount box not supplied Make the system connections to the back of the monitor and then slide the monitor onto the bracket using the hooks to hold firmly in p...

Page 5: ...5 System Connections Example 1 ON K1 The last monitor on the system line has the rear K1 switched ON 1 APKITG Manual indd 5 26 04 2017 09 43 30 ...

Page 6: ...ed ON All other monitors K1 switch to OFF 2 Please review page XXXX to set monitor to MASTER or SLAVE 3 If different types of Monitor handset are being used on the same system please refer to the supplied instructions to adjust Master Slave settings 11 to set APKITG Manual indd 6 26 04 2017 09 43 31 ...

Page 7: ...n both J3 and J2 positions 1 2 3 J1 J2 J3 NC 4 3 _ _ _ Electro magnetic lock Electronic lock BUS System Wiring LOCK1 VCC J1 Image of jumper link Lock release time N C for Electro magnetic lock N O for Electronic lock Lock Connections Example 1 APKITG Manual indd 7 26 04 2017 09 43 32 ...

Page 8: ...er 1 gives the option to set the release time 5 sec 3 sec The door station has a secondry switch LOCK2 options Please refer to the operation guide for release instructions 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 N O N C N O Volt free Volt free 12vDC300mA MAX 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 Image of jumper link Image of jumper link Lock Connections Example 2 APKITG Manual indd 8 2...

Page 9: ...9 User Guide A B C D 1 2 APKITG Manual indd 9 26 04 2017 09 43 33 ...

Page 10: ...re designed to be a quick start guide alongside the informative general user interface GUI The instructions are not exhaustive and are designed to lead the user quickly to the most often required aspects of the unit APKITG Manual indd 10 26 04 2017 09 43 33 ...

Page 11: ...and hold the Key for 5 seconds and the Installation setup screen will display 3 Press the menu button and use the right arrow to toggle between Master and Slave position 4 Press the menu button to save setting and press the exit symbol twice After 10 seconds the monitor returns back to standby APKITG Manual indd 11 26 04 2017 09 43 34 ...

Page 12: ... will display DATE and TIME settings can be found in the User Setup option Also includes ring mode for selective ringing times RECORDING VIEWING options can be found in the SD Card Memory menu PREVIEW option for all system door stations INTERNAL CALL options RING TONE Options for incoming internal and optional door bell tone selections APKITG Manual indd 12 26 04 2017 09 43 34 ...

Page 13: ...or Adjustments 1 In standby mode press the preview button and the door station s image will display 2 During the preview press the menu button the adjustment controls will appear APKITG Manual indd 13 26 04 2017 09 43 34 ...

Page 14: ...ts E Bench test the system if the issue cannot be found A The user instructions and operation of the monitor has been understood B That the lock is powered sufficiently C All system cabling is secured and properly connected D All system cabling is clear of breaks or short circuits E On the rear of the door station ensure the lock output is switching when activated by the monitor Master Slave Setti...

Page 15: ...15 APKITG Manual indd 15 26 04 2017 09 43 34 ...

Page 16: ...lite Security Products Unit 7 Target Park Shawbank Rd Lakeside Redditch B98 8YN Telephone 01527 51 51 50 Fax 01527 51 51 43 email info espuk com E OE Errors and omissions excepted D17 APKITG Manual indd 16 26 04 2017 09 43 34 ...