EsiWelma s.r.l.

    

rev. 02 of 01-09-10 / pg. 1 

 

 

E223.302 

 

 

LPG and Methane gas detectors 

for homes, recreational vehicles and similar sites 

 
Conformity standard CEI 216-8 
 

 

ESN.I.P.. 

for LPG 

 

ESN.I.G.. 

for Methane gas

 

 

 

 

 

 

 

 

___________________________________________________________________________________________ 

LPG and Methane gas detectors for homes, recreational vehicles and similar sites. 
230Vac, 12Vac/dc or 12…24Vac/dc power supply, depending on the model. 
Relay command output with double insulation voltage free contact, so suitable for any kind of solenoid 
valve or other command and alarm device. 
Possibility of parallel connection of more than one detector, also for monitoring different gases. 

___________________________________________________________________________________________ 

Use

 

The ESN.I.P/.G detectors can be used to provide a visual/audible alarm and to control a gas 
shut-off  valve  (and  to  control  other  alarm  transmitters  or  actuating  devices),  where there are 
abnormal concentrations well below the LPG or Methane gas hazard threshold.

 

___________________________________________________________________________________________ 

Operation

 

The  detector  will  enter  a  warm-up  phase  after  power-up;  this  will  take  about  60"  and  during 
this  time  the  detector  is  inoperative.      At  the  end  of  the  warm-up  phase,  the  detector  enters 
normal operation mode, and will continue in this state until it detects gas.

 

Gas detection  

In  this  case,  so  when  the  gas  concentration  exceeds  the  threshold  set-points,  the  detector 
senses  its  presence  and  goes  into  the  alarm  condition  indicated  by  the  red  LED  coming  on 
and  by  the  sound  of  the  integrated  buzzer.  After  about  20s,  the  internal  relay  is  switched  to 
transmit a command to shut off the solenoid valve and any other shut-off or alarm devices. 
Once the alarm condition is normalised, the detector is restored to its normal operating status. 
Depending  on  the  type  of  system  constructed,  it  may  be  necessary  to  manually  reset  the 
solenoid valve to restore gas flow at the dedicated reset device.

 

___________________________________________________________________________________________ 

Power supply

 

Detector 

230Vac

 

12Vac/dc

 

12…24Vac/dc

 

Recessed 

ESN.I.P/.G.x 

ESN.I.P/.G.x.D 

ESN.I.P/.G.x.E 

Wall-mounted 

ESN.I.P/.G.x + ESN.KW 

ESN.I.P/.G.x.D + ESN.KW 

ESN.I.P/.G.x.E + ESN.KW 

Table-top 

ESN.I.P/.G.x + ESN.KT 

ESN.I.P/.G.x.D + ESN.KT 

ESN.I.P/.G.x.E + ESN.KT 

Table-top (precabled) 

ESN.I.P/.G.x + ESN.KC 

ESN.I.P/.G.x.D + ESN.KC 

ESN.I.P/.G.x.E + ESN.KC 

The letter A or B inserted in field x of the product order number indicates the type of detector, i.e.: 
A = with relay command output   

B = without relay command output (visual/audible alarm) 

___________________________________________________________________________________________ 

Available 
models  
and ordering 
information

 

Summary of Contents for Sensigas ESN I Series

Page 1: ...nd of the warm up phase the detector enters normal operation mode and will continue in this state until it detects gas Gas detection In this case so when the gas concentration exceeds the threshold set points the detector senses its presence and goes into the alarm condition indicated by the red LED coming on and by the sound of the integrated buzzer After about 20s the internal relay is switched ...

Page 2: ... liquid gas in cylinders since this gas is heavier than air it will be concentrated close to the floor Install it about two metres from the gas device and about 30 cm from the floor The detector must not be installed outdoors near stoves and cooking appliances near sinks and taps near exhaust hoods windows fans etc in areas where dirt and or dust can clog the front grille of the detector where the...

Page 3: ...and LPG odorization made by the distributor together with the high sensitivity of the human olfactory apparatus make it possible to smell the presence of these gases already at extremely low concentrations so a lot earlier than the detector For operational and regulatory reasons the detector is calibrated to take action at a higher threshold which is still very far below the hazard threshold _____...

Page 4: ...several locations The contacts must be connected in series Example d Command of visual and audible alarms at the same voltage as the power supply Example e Command of visual and audible alarms at a different voltage from the power supply __________________________________________________________________________________________ _______________________________________________________________________...