background image

 

 

 
 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.

©

 ESERA-Automation, E-Service GmbH 2019

 

www.esera.de 

11308 V1.0 R1.0 Manual 

Page 1 of 5

 

Art. No. 11308 

 
 
 

User Guide 

1-Wire Bus Coupler Ethernet 

 

Configuration: 

 

Ethernet connection for 1-Wire bus 

 

Galvanic separation of 1-Wire network 
and computer 

 

LED display for power, 1-Wire activity, link 
and data transfer 

 

Top-hat rail case for the assembly of the switchboard 

 

Integrated power adapter for the voltage supply 
of the 1-Wire bus 

 

Wide voltage supply range 

 

Connection for 1-Wire bus via screw terminals 

 

Easy software-based integration as COM port 

 

Low space requirement in the switchboard 

 

Easy to assemble 
 

 
 
                       

Introduction 

Before you start assembling the 1 Wire Bus Coupler Ethernet and before you take the device into operation, 
please read these assembly and operating instructions carefully to the end, especially the section referring to the 
safety notes. 
 

Product description 

The 1-Wire Bus Coupler Ethernet enables a stable and electrically isolated connection of the 1-Wire network to a 
PC or minicomputer (e.g. Raspberry Pi). Ground loops or fault transmissions between 1-Wire network and 
computer are prevented by the use of the 1-Wire bus coupler Ethernet. 
 
Within the 1-Wire Bus Coupler, the serial to 1-Wire module DS2480 from Dallas / Maxim is used. This module - in 
combination with the complex internal power supply and the Ethernet module - are the basis for a very stable 1-
Wire network. 
The 1-wire master within the 1-wire bus coupler Ethernet (DS2480 module) supports the "Strong Pull Up" function 
and is therefore particularly suitable for the operation of large 1-wire networks. 
To configure the Ethernet interface, a suitable program "Config Tool" is available via the article download. The 
"Config Tool" is part of the "Software package", which you will find in the article Download. 
 
On computer side, the 1-Wire bus coupler is connected via a "Virtual Serial Port" (VSP). The "VSP_INSTALLER" 
tool is available for configuring the VSP. Both programs are available for download in our webshop. 
On software side, a serial interface (COM port) is available for integration into your application after installation of 
the VSP. 
An external power supply is required to operate the 1-wire Bus Coupler Ethernet module. The outputs of the 
module (5V and 1-wire bus) are short-circuit-proof and galvanically connected to the supply voltage input. For 
details on the connection, please refer to the 

“connection plan". 

The 1-Wire Bus Coupler has LED displays for "Power" and "1-Wire activity", "Ethernet Link" and "Traffic". 
 

 

Summary of Contents for 11308

Page 1: ...ound loops or fault transmissions between 1 Wire network and computer are prevented by the use of the 1 Wire bus coupler Ethernet Within the 1 Wire Bus Coupler the serial to 1 Wire module DS2480 from Dallas Maxim is used This module in combination with the complex internal power supply and the Ethernet module are the basis for a very stable 1 Wire network The 1 wire master within the 1 wire bus co...

Page 2: ...rminals up to 2 5 qmm wire cross section Output voltage 5V 10 nominally 200mA max 300mA Isolation Galvanic separation between Ethernet and 1 Wire interface Ambient conditions Temperature operation 0 C up to 50 C Air humidity 10 92 non condensing Dimensions 35 x 90 x 70mm BxHxD Protection class III Insulation class IP20 Voltage supply Input voltage 8 30VDC Power consumption typically 250mA without ...

Page 3: ... update nevertheless be necessary we will be pleased to carry out an update for you as a service We are also happy to carry out the programming of the network interface for you In this case please return the device back to us for further handling 8 Connection plan Module top side 1 Wire Bus 7 8 1 Wire GND load 9 10 1 Wire data 11 12 5V output Modul bottom side voltage supply 1 Minus input 9 30V 2 ...

Page 4: ...ined generally before the commissioning of a device whether this device or module is basically suitable for the application in which it is to be used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be retu...

Page 5: ...ding those which are not explicitly marked are trademarks registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA ...