Vandal Resistant Outdoor  

Access Control Keypads 

Manual

(SK-1123-SPQ shown)

Model

Number

2 Outputs

Backlit 

Keys

Proximity 

Reader

SK-1123-SDQ

SK-1123-SPQ

Содержание SK-1123-SDQ

Страница 1: ...Vandal Resistant Outdoor Access Control Keypads Manual SK 1123 SPQ shown Model Number 2 Outputs Backlit Keys Proximity Reader SK 1123 SDQ SK 1123 SPQ...

Страница 2: ...Lock N C Output for Fail safe Lock 1N4004 EG IN 1 2 3 4 5 6 7 8 9 12 24VDC Power Supply 2 ENFORCER Vandal Resistant Access Control Keypads SECO LARM U S A Inc Quick Installation Guide Mounting Diagra...

Страница 3: ...ge 24 Programming Instructions Follow the instructions below if the following covers your needs A new master code A single 4 digit user code for all users and no proximity cards One output to unlock a...

Страница 4: ...5 16 Programming User Codes and Proximity Cards 16 17 Programming Visitor Codes for Output 1 18 Programming Duress Codes 19 20 Programming the Output Mode and Output Timing 21 Programming the Real Tim...

Страница 5: ...0 999 and or proximity cards programmable for output 1 100 001 100 for output 2 Up to 50 01 50 possible temporary visitor codes which can be programmed for one time or limited time use 1 99 hours Outp...

Страница 6: ...y Continuous beeping Continuous flashing Output relay activation 2 1 Sec long beep In standby mode 3 1 Flash sec System refresh mode 2 Beeps Fast flashing for 2 5 min Card code already stored 1 Long b...

Страница 7: ...6 Finish assembly by attaching the keypad to the back box with the included installation screws 1 Always disconnect power before servicing the keypad Do not apply power until all connection wiring is...

Страница 8: ...device when the user enters a duress code Ground Common ground output Door Sensor Connect to an optional N C sensor such as a magnetic contact to monitor if a door is open or closed Connect to ground...

Страница 9: ...k 1 Electric Lock 2 Door 1 Sensing Common Ground Cross wire connection for inter lock functions Door 2 Sensing 12 24VDC Power Supply 12 24VDC Power Supply 9 ENFORCER Vandal Resistant Access Control Ke...

Страница 10: ...Duress codes Assigned to specific users as a way to send a silent alert if forced to use the keypad under duress 2 Proximity card only Standard 125kHz EM125 proximity cards can be used to activate ou...

Страница 11: ...about 1 minute During this power up time if needed use Direct Access to Programming DAP to reset the master code see Direct Access to Programming DAP on page 29 1 Turn off the beeping before the 1 mi...

Страница 12: ...itor codes for output 1 No default must be programmed 17 18 41 Duress codes for output 1 No default must be programmed 19 20 42 Duress codes for output 2 No default must be programmed 19 20 51 Output...

Страница 13: ...to their default values and are ready to be re programmed At this point the keypad is still in programming mode The master code is used to enter programming mode The master code does not serve as a u...

Страница 14: ...rogramming Mode on page 11 2 Enter the new super user code 02 xxxx NOTE XXXX represents the new super user code which can be 4 to 8 digits long There can be only one super user code for the keypad Pro...

Страница 15: ...s of programming 2580 9 NOTE For more information on programming timed or toggle mode see Programming the Output Mode and Output Timing on page 21 The right LED will remain red while output 1 is disab...

Страница 16: ...user code to activate outputs 1 or 2 3 Card Unique user code The most secure level This code is programmed separately for each card and can be unique to the card or the same code can be used for a gro...

Страница 17: ...he master super user common user visitor duress and user codes cannot be the same Examples 1 Program only a proximity card for user ID 017 for output 1 10 1 017 READ CARD 2 Program a user code for use...

Страница 18: ...que visitor IDs for visitor codes for output 1 0999 Delete all currently programmed visitor codes Valid Duration 00 Set a one time code This code can only be used once by a visitor after which it is a...

Страница 19: ...rogrammed see Programming User Codes and Proximity Cards on page 16 The duress code should be easy to remember For instance it can be the same as a user s normal user code but with a single digit chan...

Страница 20: ...ctivate the duress output Only a normal user code card super user code or a master code can deactivate the duress output NOTE A duress code can also be used in conjunction with a user card to activate...

Страница 21: ...put B Output Mode and Time Outputs 51 Output 1 52 Output 2 Output Mode and Time 0 Start stop toggle mode In this case the output starts when a user code and or user card is entered and stops when a us...

Страница 22: ...every 5 seconds In such case the Real Time Clock must be reprogrammed or the Output 1 Auto Disable Time must be cleared If the output 1 auto disable time is not programmed losing power will not cause...

Страница 23: ...ogram Output 1 Auto Disable Time HHMM Start Time HHMM End Time Start Time Start time for output 1 auto disable time HH represents hours and MM represents minutes in the military 24 hour time format fr...

Страница 24: ...deactivated using any user code or user card or via the super user code 5 to 10 After 5 to 10 successive false attempts using incorrect user codes or user cards the keypad will lock for 15 minutes or...

Страница 25: ...re disabled However the warning and power up delay beeps remain active This provides for a quieter work environment To Program To enable keypad audible mode default 71 1 To enable keypad silent mode 7...

Страница 26: ...optional magnetic contact or other door protection switch or device the keypad can be programmed to beep when a door has been forced open The keypad beep can be set to activate for 1 to 999 seconds 1...

Страница 27: ...ropped open This prompts authorized users to close a door that was not closed properly or to investigate a door that may have been deliberately propped open 1 Door propped open warning OFF default 81...

Страница 28: ...lt Press the egress button momentarily for silent egress operation 2 Momentary contact with warning beep Press the egress button momentarily The keypad will beep for the programmed delay time before l...

Страница 29: ...ds or until the door is unlocked Direct Access to Programming DAP Direct Access to Programming DAP is used to reset the master code if it is forgotten DAP will not change the programming of the keypad...

Страница 30: ...30 ENFORCER Vandal Resistant Access Control Keypads SECO LARM U S A Inc Notes...

Страница 31: ...code READ CARD 2 Short beeps and a rapidly flashing amber LED indicates the card is accepted and the keypad is waiting for the Common user code 3526 1 Long beep indicates that the door can be opened S...

Страница 32: ...ributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such e...

Отзывы: