1.0  IMPORTANT RECEIVING INSTRUCTIONS

Visually inspect all components for shipping damage. Shipping 
damage is not covered by warranty. If shipping damage is found, 
notify carrier at once. The carrier is responsible for all repair and 
replacement costs resulting from damage in shipment.

2.0  SAFETY ISSUES

Read all instructions, warnings and precautions 
carefully. Follow any recommended safety 
precautions to avoid personal injury or damage to 

the jack. Enerpac cannot be responsible for any damage or injury 
from unsafe use, lack of maintenance or incorrect operation.

 

Do 

not remove warning labels, tags, or decals.

 

In the event any 

questions or concerns arise, contact ENERPAC or a local Enerpac 
distributor for clarifi cation.

The maximum working pressure of the jack hydraulic system 
varies between 6,000 and 10,200 psi [414 and 703 bar], 
depending on jack model. Refer to pressure listings in Table 1, 
General Specifi cations. 

If you have never been trained on high-pressure hydraulic safety, 
consult your distributor or service center for a free Enerpac 
Hydraulic Safety Course.

CAUTION

 is used to indicate correct operating or maintenance 

procedures and practices to prevent damage to, or destruction of 
equipment or other property.

WARNING

 indicates a potential danger that requires correct 

procedures or practices to avoid personal injury.

DANGER

 is only used when your action or lack of action may 

cause serious injury or even death.

Failure to comply with the following safety precautions could 
result in equipment damage and/or personal injury:

WARNING:

 Wear proper personal protective gear when 

operating hydraulic equipment.

WARNING:

 The jack is to be used for lifting only! Support 

the load after completing the lift using approved 
accessories or by other appropriate means. Never get 

under a load being supported only by the jack.

WARNING:

 Never exceed the rated capacity of the jack. 

Allow for a margin of safety that accounts for possible 
shifting loads or side loading conditions.

          

DANGER:

 To avoid serious personal injury, keep 

hands and feet away from hydraulic cylinder and 
related components during jack operation.

DANGER:

 Do not handle pressurized lines. Escaping oil 

under pressure can penetrate the skin, causing serious 
injury. If oil is injected under the skin, see a doctor 

immediately.

WARNING: 

The jack's internal relief valve must not be 

repaired or adjusted except by an authorized service 
center.  Never tamper with overload protection devices. 

Higher settings may result in equipment damage and/or personal 
injury.

CAUTION: 

When jack is not in use, fully retract the 

cylinder and protect the entire unit from external damage. 
Keep the jack clean, avoid weld splatter, and store in a 

clean dry area. INSPECT ALL JACK COMPONENTS BEFORE USE.

CAUTION:

 Keep the jack away from fl ames  and 

heat. For optimum performance, do not expose the 
jack to temperatures above 65 °C [150 °F].

WARNING: BE SURE LIFTING ARRANGEMENT IS 

STABLE BEFORE LIFTING LOAD. 

Use jack only on a 

solid and level surface, capable of supporting the load 

and the base of the jack. Always center the load on the lifting 
saddle of the jack. If the jack is not perpendicular to the load, 
slipping or loss of load is possible.

WARNING: 

Distribute the load evenly when performing 

lifts with multiple jacks. Failure to heed this warning may 
cause loss of load and/or failure of the jack, resulting in 
property damage and/or personal injury.

IMPORTANT:

 Hydraulic equipment must only be 

serviced by a qualifi ed hydraulic technician. For repair 
service, contact the Authorized ENERPAC Service Center 

in your area. To protect your warranty, use only ENERPAC oil.

WARNING:

 Immediately replace worn or damaged parts 

with genuine ENERPAC parts. Standard grade parts will 
break causing personal injury and property damage. 

ENERPAC parts are designed to fit properly and withstand high 
loads.

CAUTION:

 To avoid damage to jack internal 

components, do not continue pressurizing the jack 
cylinder after it reaches maximum extension or 

retraction.

Index:

 English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-20
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A 
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A 
Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A
Hollands  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A
Português  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A
Suomalainen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A
Norsk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A
Svensk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A

中文

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A

日本語

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  N/A

Summary of Contents for Pow'r-Riser PR Series

Page 1: ...a margin of safety that accounts for possible shifting loads or side loading conditions DANGER To avoid serious personal injury keep hands and feet away from hydraulic cylinder and related components...

Page 2: ...PRAMA100__L PRASA100__L 9 700 669 PRASA150__L 10 200 703 PRASA200__L 10 200 703 Load Rating Model US Tons Metric Tons kN PRAMA060__L 60 54 533 PRAMA100__L PRASA100__L 100 90 889 PRASA150__L 150 136 1...

Page 3: ...s the motor will start automatically when either pendant button is depressed 3 Open the air supply valve callout 4 Using the regulator knob adjust the air pressure to a minimum of 80 psi 5 5 bar IMPOR...

Page 4: ...y support the load for any period of time after the lift has been completed Support the load with U Rings or other suitable load supports immediately after it has been lifted to the desired height WAR...

Page 5: ...valve to stop the motor AFTER COMPLETING THE JOB Fully retract the cylinder and close the air supply valve With the motor off shift the control valve several times between the extend and retract posi...

Page 6: ...compensated for by use of plywood or other suitable compression material alone Table 6 Load Caps Jack Model Load Cap Model Numbers Non Swivel Load Cap standard Swivel Load Cap optional accessory PRAM...

Page 7: ...Cap Steel U Ring top Recess of U Ring Steel U Ring bottom Aluminum U Rings Locator on each U Ring and at top of cylinder housing Figure 5 U Ring Stacking Arrangement typical 6 0 MAINTENANCE 6 1 Maint...

Page 8: ...gulator Figure 6 Oil Change 6 3 Air Line Filter Regulator See Figure 7 Every 30 hours of operation Check the lter bowl for water Drain any water if present Inspect air lter element inside lter bowl Re...

Page 9: ...nsufficient compressed air volume Check air regulator setting Increase volume of compressed air or increase size of supply air line to meet air ow and pressure requirements Internal pressure leaks or...

Page 10: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 11: ...gato Permitir un margen de seguridad que prevenga la posibilidad de desplazamiento o desviaci n de la carga PELIGRO Para evitar lesiones personales mantenga las manos y los pies alejados del cilindro...

Page 12: ...l nivel del lubricador para l nea de aire anotaci n 7 y a ada m s lubricante si es necesario Utilice un aceite detergente SAE 10 ISO 32 o un lubricante anticongelante autorizado Consulte la Secci n 6...

Page 13: ...edas 19 V lvula de aire del neum tico 20 Almacenamiento de los anillos en U No disponible en todos los modelos RAISE LOWER 7 1 15 3 18 19 16 13 5 8 9 7 12 4 10 11 2 14 20 Figura 1 Caracter sticas y co...

Page 14: ...a corta PRASA20016L est equipado con dos c ncamos para izar Los modelos de carrera corta de la serie PRAMA060 PRA_A100 y PRASA150 no tienen instalados c ncamos para izar ADVERTENCIA Eleve el gato util...

Page 15: ...ula de control a la posici n central neutral de retenci n Si el gato tiene un mando remoto libere el bot n de la echa hacia arriba para que la v lvula vuelva a la posici n central neutral de retenci n...

Page 16: ...pcionales Modelo de piezas de distancia Anchura de cada uno mm Pulgadas PRS1 25 1 PRS2 51 2 PRS3 76 3 Conjunto de piezas de distancia PRS4 El conjunto incluye PRS1 PRS2 y PRS3 1 cada uno PRECAUCI N Nu...

Page 17: ...cilindro extendido Est n disponibles en 5 longitudes diferentes para cada modelo de Pow r Riser Assembled View Anillo de soporte de carga Plataforma de carga Anillo en U de acero parte superior Anillo...

Page 18: ...alcance los 60 C 150 F Cuando haya un alto grado de humedad en el entorno y o cambios de temperatura extremos que puedan provocar la condensaci n del aceite dentro del dep sito Cuando haya un entorno...

Page 19: ...lenciador v ase la gura 8 Cada 30 horas de funcionamiento Compruebe que no haya suciedad en el silenciador Si est obstruido reemplace el silenciador por uno nuevo que tenga las mismas especi caciones...

Page 20: ...r ulico en un centro de servicio t cnico autorizado Enerpac Repare o sustituya los componentes seg n sea necesario Ajuste demasiado bajo de la v lvula de descarga interna o de la v lvula de alivio en...

Page 21: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 22: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 23: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 24: ...7 495 98090 92 sales ru enerpac com Singapore Actuant Asia Pte Ltd 83 Joo Koon Circle Singapore 629109 T 65 68 63 0611 F 65 64 84 5669 Toll Free 1800 363 7722 sales sg enerpac com South Korea Actuant...

Reviews: