background image

Manufactured By

Module-RCM-I-Refrigerant-Module-Installation-050519

RCM-I Refrigerant Module

Installation Manual

Small Duct High Velocity Heating, Cooling and Home Comfort Systems

RCM-I-70 (2.5-3 Tons)

RCM-I-100 (3.5-5 Tons)

Includes:

Service/Access Ports

L-Mounting Brackets 

Double Sided Mounting Tape

Carry-Over Screen 

For use with HVS-36 & HVS-60 Variable Speed Heat Pumps

Summary of Contents for Hi-Velocity RCM-I Series

Page 1: ...nt Module Installation Manual Small Duct High Velocity Heating Cooling and Home Comfort Systems RCM I 70 2 5 3 Tons RCM I 100 3 5 5 Tons Includes Service Access Ports L Mounting Brackets Double Sided Mounting Tape Carry Over Screen For use with HVS 36 HVS 60 Variable Speed Heat Pumps ...

Page 2: ... is for use with HVS 36 and HVS 60 Inverter Heat Pump Condensing Units It does not come with thermal expansion valve as there are internal EXVs inside the Heat Pump When installing the RCM I Modules DO NOT INSTALL WITH TXVs The module will come with access ports that will need to be installed to read refrigerant pressures temperatures at the Evaporator RCM I Fig 01 shows approximate installation l...

Page 3: ...pipe every 5 feet or whatever local code states Run the pipes in the most direct route possible taking into account structural integrity building details and local building codes Minimum refrigerant pipe length is 16ft 6m If going less than 16 ft coil the additional copper pipe up in horizontal loops to ensure proper oil return If the evaporator is located above the condenser slope any horizontal ...

Page 4: ... out all refrigerant then weighing it back in based on the factory charge listed on the rating plate plus any additional refrigerant needed based on page 5 of Module HVS Variable Speed Heat Pump Manual Charging Wiring Outdoor Unit Make all connections to the outdoor unit with rain tight conduit and fittings Most building codes require a rain tight disconnect switch at the outdoor unit as well alwa...

Page 5: ...lar ducts A variance of 20 is allowable for sizing return ducts that connect to the RCM I or Hi Velocity Systems unit Where allowed by local codes a single return air grill may be used Note Return air grill must have equal minimum of free air area to return air Table 03 Return Air Duct Sizes Unit Rigid Ø Flex Ø Min Sq Inches Sq cm 50 51 52 12 305mm 14 356mm 120 774cm 70 71 12 305mm 14 356mm 120 77...

Page 6: ... Connection Sizes Liquid Line Lq 1 2 13mm 1 2 13mm Suction Line S 7 8 22 3mm 7 8 22 3mm Drain Connection 3 4 M CPVC 19mm 3 4 M CPVC 19mm Access Ports Yes Yes Freeze Stat Yes Yes Shipping Weight 34 lbs 15 4 kg 47 lbs 21 31 kg Module Size L x W x H 19 3 8 x 10 1 8 x 18 1 2 492mm x 257mm x 470mm 25 3 8 x 10 1 8 x 18 1 2 645mm x 257mm x 470mm RCM I Specifications Refrigerant Cooling Module 2 Smaller c...

Page 7: ...vel and only to the fan coil unit and module It does not include connections attachments and other products or materials furnished by the installer Terms and Conditions Any repair performed under warranty must be approved by Energy Saving Products Ltd for this warranty to be valid This warranty replaces all other warranties expressed or implied www hi velocity com Should there be multiple consecut...

Page 8: ... complete with an in house test lab Energy Saving Products prides itself on Customer Service and provides design services and contractor support For all of your Heating Cooling and Indoor Air Quality needs the Hi Velocity System is the right choice for you Phone 780 453 2093 Fax 780 453 1932 Toll Free 1 888 652 2219 www hi velocity com Hi Velocity HE Z Fan Coils Green Technology Build Smart Breath...

Reviews: