background image

 

                                                                                                                                                             

 

 

 

 

 

 

 

 
 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

p

e

ra

ti

n

g

 M

a

n

u

a

  

 

 

D

 

 

 

ESE 2200 P

 

ESE 3200 P 

                 Article No. 290100

 

                  Article No. 290101 

 

   

Power Generators 

Summary of Contents for ESE 2200 P

Page 1: ...Operating Manual D ESE 2200 P ESE 3200 P Article No 290100 Article No 290101 Power Generators...

Page 2: ...GmbH This documentation including all of its parts is protected by copyright Any use or modification beyond the restrictions of the Copyright Act is forbidden and subject to penalty without the consen...

Page 3: ...tor 9 Generator components 10 Function and mode of operation 11 Operation 12 Mounting the wheelset 12 Transporting the generator 14 Adding draining fuel 15 Fill the generator with motor oil 17 Startin...

Page 4: ...ovisions 34 Environmental protection 1 General note The illustrations in these operating instructions do not always comply completely with the actual design in particular with regard to the colour and...

Page 5: ...commercial use The generator is for producing 220V to 240V alternating cur rent at a frequency of 50 Hz and a nominal load of 2200 watts for cos phi 1 also see p 31 Included in delivery First inspect...

Page 6: ...ed The standard labels applied are in German Dismantling the transport securing devices 1 Loosen the fastening screws of the red transport secur ing devices on both sides see Fig 2 1 2 Take the securi...

Page 7: ...afety instructions Keep the operating manual at hand during operation In general keep children and pets away from the genera tor Operate the device only on a level non skid surface If necessary secure...

Page 8: ...omponents of the gen erator and that the insulation is not damaged in this way DANGER RISK OF DEATH Asphyxiation hazard Operation in closed rooms is prohibited Always make sure there is adequate venti...

Page 9: ...wing labels must be attached to the generator and be kept in clearly legible condition No Label Designation No Label Designation 1 Model plate 6 Note Fire hazard 2 Note Hazardous volt age 7 Note on RO...

Page 10: ...omponents 1 1 Dipstick oil cap 8 Protective contact socket 230V 2 Oil drain screw 9 Earthing connection 6 Motor ON OFF switch 10 Transport handle wheelset 7 Circuit breaker triggered during overload o...

Page 11: ...e low vibration suspension Current is drawn through two 230 V 50 Hz splash proof safety sockets An automatic voltage regulator AVR controls the voltage of the generator within the nominal speed range...

Page 12: ...ls or slides away Bear in mind that the device weighs approx 50 5 kg Use two people to mount the wheelset with one person holding the device Use the mounting elements delivered with the device 1 Stand...

Page 13: ...8 Fig 8 Mounting the wheelset 3 6 Mount the plate with the feet to the frame using two bolts and nuts M8 see Fig 8 7 Stand the device on the wheels and rubber feet 8 Put a plastic disk on the fasteni...

Page 14: ...he other carrying handle This completes mounting of the wheelset and handles Fig 9 Mounting the wheelset 4 Transporting the generator The generator must be turned off The generator must have cooled do...

Page 15: ...into the carburettor Carefully wipe up leaking fuel 1 Grip the device by the support frame 2 Lift the generator 3 Carry the generator to the place of use 4 Set down the generator 5 Let go of the suppo...

Page 16: ...ompletely Use a filling tool CAUTION The wrong fuel destroys the motor Use only lead free ROZ 95 premium petrol Fig 10 Fill level of tank Read the gauge see Fig 10 1 You have an overview of the curren...

Page 17: ...ack and forth 4 Hold the end of the hose in the collection container 5 Turn the fuel tap to ON The fuel is drained out 6 Put the fuel hose completely back onto the fuel tap and secure it again with th...

Page 18: ...port 3 Pour in oil 0 6l SAE10W 40 to right below the edge of the oil filling port 4 Remove the filling tool 5 Screw in the dipstick 6 Repeat the filling process if the oil level is too low 7 Screw the...

Page 19: ...and sparks away 1 Inspect the device according to Maintenance plan see p 24 2 Set motor switch to ON If the motor is cold turn the choke lever to the left see Fig 12 3 If the motor has already warmed...

Page 20: ...device Connecting disconnecting appliances Proceed as follows to connect appliances to the generator The device should be fully warmed up If possible turn the appliance off before connecting Set the c...

Page 21: ...maximum output of 2 200 W can be used Appliances can be connected with a safety plug 230 V AC 1 Flip the socket cover up 2 Insert the plug into the socket The appliance is connected How to disconnect...

Page 22: ...ial operating environments Use a slightly moistened lint free cloth with some dish detergent Make sure that no liquid can get inside the generator Decommissioning storing the generator A dry dust free...

Page 23: ...If the device will not be used for an extended period the motor oil see page 25 and the petrol see page 15 must be drained It is best to cover the generator with a cloth The device has been decommiss...

Page 24: ...Motor oil see p 25 change X check X Air filter see p 26 clean replace X 1 Spark plugs see p 28 clean check gap X Valves test adjust X 3 Check fit of screws and bolts X 2 X Fuel lines check replace X...

Page 25: ...an or rag under the screw plug or dipstick in order to catch the escaping oil CAUTION Leaking motor oil can contaminate soil and groundwa ter Use an oil collection container Recycle used motor oil DAN...

Page 26: ...above the mark oil must be drained The oil has been topped off How to drain the oil 1 Set up an oil collection container to catch the draining oil 2 Screw the dipstick out of the motor 3 Now screw out...

Page 27: ...moist lint free cloth 4 Clean the air filter insert with kerosene in a suitable con tainer 5 Pour some motor oil SAE10W 40 onto the filter and cleanly distribute it Press excess oil back out 6 Reinser...

Page 28: ...ew the spark plug out 4 The spark plug should be light to dark brown Check the electrode gap with a gauge It should be 0 6 mm to 0 7 mm see Fig 17 If the insulator s ceramics are damaged the plug must...

Page 29: ...ble 6 Set the motor switch to ON 7 Pull the motor s starter cord and see if a strong ignition spark is visible If necessary replace the spark plug 8 Screw the plug back in by hand and then tighten it...

Page 30: ...ket dirty or loose Clean the spark plug socket Set the gap if necessary Spark plug dirty Clean the spark plug replace if necessary see p 28 The machine does not start Warning light when starting Oil i...

Page 31: ...A Weight empty 40 5 48 5 kg Tank capacity ROZ95 premium lead free fuel 17 17 l Motor oil capacity SAE10W 40 0 6 0 6 l Dimensions LxWxH w o wheelset 675x425x440 648x422x465 mm Sound power level at work...

Page 32: ...Class G1 Mfg 2012 m 40 5 kg Nominal output in kW Art No ID serial number Nominal output factor Nominal frequency in hertz Nominal voltage in volts Nominal current in amperes International protection c...

Page 33: ...Technical specifications 33 Declaration of Conformity...

Page 34: ...ths from the date of purchase For warranty claims or replacement parts please contact the dealer from whom the product was purchased Always be sure to include the following documents with your defec t...

Page 35: ...9737 44 E mail Service endress stromerzeuger de ENDRESS Elektroger tebau GmbH Neckartenzlinger Stra e 39D 72658 Bempflingen Tel 49 0 71 23 9737 0 Fax 49 0 71 23 9737 1 0 E mail Info endress stromerze...

Page 36: ...electronic appliances as well as batteries must not be discarded with domestic waste At the end of their service life the user is required by law to hand over electrical and electronic devices as well...

Page 37: ...37...

Reviews: