Summary of Contents for SwimCross

Page 1: ...SwimCross Exercise Systems OWNER S MANUAL by Endless Pools...

Page 2: ...___________________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE __...

Page 3: ...ONTROL 13 FILTER CYCLES 13 ALL OFF MEMORY ON 13 WI FI IN TOUCH OPTIONAL 13 WATER QUALITYAND MAINTENANCE BASIC INFORMATION 14 CHEMICAL SAFETY 14 HOW TOADD CHEMICALS TO THE WATER 14 FUNDAMENTALS OF WATE...

Page 4: ...risk of injury Refer all servicing to qualified service personnel Do not attach an external antennae to a SWIMCROSS Exercise System audio system unless installed by a licensed electrician in accordanc...

Page 5: ...g long hair or hanging jewelry away from rotating jets or other moving components Long hair should be tied up or placed under a bathing cap Safe water temperature for aquatic exercise is approximately...

Page 6: ...chemicals and cleaners DON T Leave the SWIMCROSS Exercise System exposed to the sun without water or a cover in place Exposure to direct sunlight can cause solar distress of the shell material Roll or...

Page 7: ...ater 10 Be sure that the location you choose is stable It must be able to support the weight of the SWIMCROSS Exercise System when it is filled with water plus the weight of the occupants The SWIMCROS...

Page 8: ...ent compartment back side of SWIMCROSS Exercise System Slide panel towards center and remove repeat for other panel Insert power wires into SWIMCROSS Exercise System from either side towards the botto...

Page 9: ...WITH GFCI SUBPANEL PROVIDED INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS REFER TO THE WIRING INSTRUCTIONS INCLUDED WITH THE SUB PANEL FOR DETAILED WIRING INSTRUCTIONS Electrical Requirements 2 DOOR PA...

Page 10: ...de a unique pulsating massage 6 The Midsize Directional Hydromassage jets with eyeball nozzles deliver a direct more focused massage 7 The Midsize rotational Hydormassage jets provide a rotating massa...

Page 11: ...sage jet system Rotate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE YOU FILL YOUR SWIMCROSS EXERCISE SYSTEM Make sure your SWIMCROSS Exercise System has been pr...

Page 12: ...jets button and place all jet pumps on High Once the jet system is fully operational as indicated by strong non surging jets priming of the SWIMCROSS Exercise System is complete To turn off the jets...

Page 13: ...etting A green check mark will appear on the selected icon to confirm When in Economy mode the heating set point will be reduced by 20 F 11 C which means that the heating system will not come on durin...

Page 14: ...ors are archived chronologically from most recent to oldest top to bottom The Error log page shows the error code the date of the error and the time To see more details on an error select it with midd...

Page 15: ...OT work when AUX is selected as the source TURNING POWER ON OFF Press the top right lit button to start the audio on or off process SELECTING THE SOURCE Press the top left lit button to select a sourc...

Page 16: ...button when in the home screen to activate all lights Press the lower right button a second time to shut all lights off when turning back on after several seconds the same light mode will appear Ever...

Page 17: ...dose your SWIMCROSS Exercise System Handle all containers with care Store in a cool dry well ventilated place Always keep chemical containers closed when not in use Replace caps on their proper contai...

Page 18: ...sult with your dealer for an appropriate program a CLEAN SCREEN pre filter The CLEAN SCREEN pre flter should be used at every fill and top off to remove contaminants from the fill water especially iro...

Page 19: ...se If the SWIMCROSS Exercise System is being used over an extended period of time such as a whole afternoon or evening additional sanitizer will be needed Required a One Silver Ion cartridge per 500 g...

Page 20: ...System water will be safe for you to use once the FreeAvailable Chlorine residual level has dropped below 5 0 ppm IMPORTANT If you will not be using your SWIMCROSS Exercise System for an extended per...

Page 21: ...chemical is a byproduct of the ozone generating process Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone Oxidizer The use of an oxidizing chemi...

Page 22: ...se System in the Standby mode then proceed as follows 1 Find the filter grate inside the SWIMCROSS Exercise System 2 Pull the filter grate from the bottom up until it unlocks from the wall IMPORTANT O...

Page 23: ...help to maximize the SWIMCROSS Exercise System s energy efficiency NOTE When warmer weather returns approx 60 70 F the insulating kit must be removed to prevent overheating of the jet pump WINTERIZING...

Page 24: ...mends Stain Scale Defense 3 Keep all cleaners out of the reach of children and use care when applying SWIMCROSS EXERCISE SYSTEM CABINET All SWIMCROSS Exercise Systems use the exclusive all climate cab...

Page 25: ...ermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures High temperature All ENDLESS POOLS SWIMCROSS Exercise System models are...

Page 26: ...nded particles organic matter Overused or old water Clean filters Shock SWIMCROSS Exercise System with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jet pump s and clean...

Page 27: ...POOLS dealer Noisy pump or motor Low water level Add water to normal level 6 inch below bar top Pump motor runs but low or no water jet pressure Air control valve closed Water Valves are closed Dirty...

Page 28: ...10 occupants assuming an average occupant weight of 175 lbs X200 12 0 x 7 5 50 100 square feet 4 000 1 210 gallons 2 225 lbs 14 070 lbs 185 lbs per square foot 230 volt 60 amp Single phase GFCI prote...