READ AND SAVE THESE INSTRUCTIONS

Model No.

CFDR

Series Downrod

Extension Rods

Ceiling Fan Downrod Extension Kit

Owner’s Manual

Part No. F40BP70740002

Form No. BP7074-2

Form No. BP7074-2
Part No. F40BP70740002

Printed in China 11/07

Figure 6

Figure 7

Figure 8

Figure 9

12.

Cut the black, blue and white leads to a 2”
to 3” length, then strip 3/8” of insulation
from the leads (Figure 8).

13.

Three new #18 GA stranded leads (black,
white and blue) should be cut a length of 16
to 18 inches longer than the downrod being
used. Feed all three new leads through the
motor wireway, enough to make splices
(Figure 9). Strip 3/8” of insulation and
connect the new leads to matching color
motor leads. Use wire connectors that are
UL listed and sized to connect two #18 GA
stranded wires. After splices are made,
follow Steps 3 through 8. Assemble and
install the ceiling fan per instructions in the
Ceiling Fan Owner’s Manual.

Do not exceed 6-foot downrod length. All
downrods must be Emerson downrods.
Use of other brand downrods will void
the warranty on this fan.

WARNING

!

WARNING:

TO AVOID FIRE, SHOCK, AND SERIOUS PERSONAL INJURY, FOLLOW THESE

INSTRUCTIONS.

Safety Instructions

1. READ YOUR OWNER'S MANUAL CAREFULLY AND KEEP IT FOR FUTURE

REFERENCE.

2. BEFORE SERVICING OR CLEANING UNIT, SWITCH POWER OFF AT SERVICE PANEL

AND LOCK SERVICE PANEL DISCONNECTING MEANS TO PREVENT POWER FROM
BEING SWITCHED ON ACCIDENTALLY. WHEN THE SERVICE DISCONNECTING
MEANS CANNOT BE LOCKED, SECURELY FASTEN A WARNING DEVICE, SUCH AS A
TAG, TO THE SERVICE PANEL.

3. BE CAREFUL OF THE FAN AND BLADES WHEN CLEANING, PAINTING, OR

WORKING NEAR THE FAN. 

4. DO NOT PUT ANYTHING INTO THE FAN BLADES WHILE THEY ARE TURNING.

Additional Safety Instructions for Installation

1. TO AVOID POSSIBLE SHOCK, BE SURE ELECTRICITY IS TURNED OFF AT THE FUSE

BOX BEFORE WIRING.

2. ALL WIRING MUST SATISFY NATIONAL AND LOCAL ELECTRICAL CODES.

ELECTRICAL INSTALLATION SHOULD BE MADE OR APPROVED BY A LICENSED
ELECTRICIAN. USE THE NATIONAL ELECTRIC CODE IF LOCAL CODES DO NOT
EXIST.

3. THE OUTLET BOX AND JOIST MUST BE SECURELY MOUNTED AND CAPABLE OF

RELIABLY SUPPORTING AT LEAST 50 POUNDS. USE ONLY U.L. OUTLET BOXES
LISTED AS ACCEPTABLE FOR FAN SUPPORT, AND USE THE MOUNTING SCREWS
PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR
SUPPORT OF LIGHT FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND
MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

4. THE FAN MUST BE MOUNTED WITH THE FAN BLADES AT LEAST 7 FEET FROM THE

FLOOR TO PREVENT ACCIDENTAL CONTACT WITH THE FAN BLADES.
DO NOT COMBINE 2 OR MORE DOWNRODS.

5. WHEN ASSEMBLING FAN, BE SURE THAT DOWNROD IS SECURELY ATTACHED TO

THE MOTOR BY A STAINLESS STEEL SCREW AND TO THE HANGER BALL BY A
CROSS PIN (BOTH SUPPLIED WITH FAN), AND MAKE SURE SETSCREWS AT MOTOR
END AND HANGER BALL ARE TIGHTENED SECURELY AGAINST THE DOWNROD.
FAILURE TO DO SO COULD RESULT IN THE FAN BECOMING LOOSE AND FALLING.

6. FOLLOW THE RECOMMENDED INSTRUCTIONS FOR THE PROPER METHOD OF

WIRING YOUR CEILING FAN. IF YOU DO NOT KNOW ENOUGH ABOUT ELECTRICAL
WIRING, OR NEED ELECTRICAL WORK NOT DESCRIBED IN THIS MANUAL, HAVE
YOUR FAN INSTALLED BY A LICENSED ELECTRICIAN.

(For use with Emerson Ceiling Fan

Unthreaded Downrods)

11.

Feed the white wire down through the
motor wireway and pull completely through
the wireway (Figure 7).

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant • St. Louis, MO 63136