Page 1
1000002038 (Rev. A – 7/14)
EZWS(M)*3(P)KSA LZWS(M)*3(P)KSA
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN,
CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL
CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS
INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT
THE BOTTLE FILLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
FIG. 2
FIG. 1
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL
AND OTHER APPLICABLE CODES. After installation, leave these instructions
inside the fountain for future reference.
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
Installation/Care/Use Manual
EZH20 In Wall Bottle Filling Station
For Commercial Use
Uses HFC-R134a Refrigerant
EZWS(M)*3(P)KSA
LZWS(M)*3(P)KSA
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED IN
POSITION
PUSH IN COLLET TO
RELEASE TUBE
PUSHING TUBE IN
BEFORE PULLING
IT OUT HELPS TO
RELEASE TUBE
WARNING
A MEANS FOR DISCONNECTING ELECTRICAL SUPPLY POWER TO THE UNIT MUST BE INCORPORATED IN
THE FIXED WIRING ACCORDING TO THE WIRING RULES. THIS IS TO ALLOW DISCONNECTION OF THE UNIT
FROM THE ELECTRICAL SUPPLY AFTER INSTALLATION.