background image

 

 

 

                    

WTMD

 

U

U

s

s

e

e

r

r

s

s

 

 

M

M

a

a

n

n

u

u

a

a

l

l

  

 

 

Release: 05.12

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

European Branch: 

Elektral Businesspool GmbH 

Hatzper Bogen 27,  

D-45133 Essen  

GERMANY 

Phones  :+49(0)201 814 10948 

Fax       :+49(0)201 364 4342 

e-mail   :[email protected]

MAIN CONTACT-FACTORY: 

Elektral Elektromekanik A.S. 

Ataturk Industrial Zone

  

M.K. Ataturk Blv. 23 Cigli  
35620 Izmir -TURKEY  

Phones  : +90(0)232 376 7300 

Fax       : +90(0)232 376 7030 

e-mail

:  [email protected]

 
 

 
 
 
 
 

Form: GKD s9sX50125 

 

 

www.elektral.com.tr

  

      

www.ThruScanmetaldetectors.com

 

Summary of Contents for ThruScan

Page 1: ...nes 49 0 201 814 10948 Fax 49 0 201 364 4342 e mail elektral elektral com MAIN CONTACT FACTORY Elektral Elektromekanik A S Ataturk Industrial Zone M K Ataturk Blv 23 Cigli 35620 Izmir TURKEY Phones 90...

Page 2: ...3 CONTROL DISPLAY PANEL INDICATION INFORMATION 16 3 1 Control Panel 16 3 1 1 LCD Display 16 3 1 2 Alarm Locater Display 16 3 1 3 LED VU Display 16 3 1 4 Battery Indicator 17 3 1 5 Pacing Light Indicat...

Page 3: ...ON 29 5 1 Normal Operating Mode 29 5 2 Routine Tests 29 5 3 Alarm State 30 6 TECHNICAL SPECIFICATIONS 30 6 1 Electronics 30 6 2 Detection Field 30 6 3 Language 31 6 4 Self Test 31 6 5 Sensitivity 31 6...

Page 4: ...ional Questions 42 10 APPENDIX 44 10 1 Certificate of Expertise 44 10 2 SRC SCADA Remote Control 44 10 2 1 ThruScan s9 SRC SCADA Program Manual 45 10 2 2 ThruScan sX SRC SCADA Program Manual 46 10 3 I...

Page 5: ...ruScan will receive your approval as well with their quality service guarantee and economy Thank you for selecting a product manufactured by Elektral A S at an international alliance We hope to meet a...

Page 6: ...side the equilateral triangle informs the user that in the context of the product there is enough amount of uninsulated dangerous voltage to cause an electric shock DO NOT OPEN ThruScan ELECTRONIC CAS...

Page 7: ...an electronic PIN CODE as a precaution towards unauthorized people Do not share your password Contact factory when it is fogotten Assemble your ThruScan on a horizontal and flat floor Make sure to fix...

Page 8: ...experts that has no effects on the peacemakers the pregnant women and as well at magnetic media A report of expertise on this issue is presented in Attachment 1 See Section 10 1 Protect your ThruScan...

Page 9: ...ocated on the side panels of the exit side of the gateway Zone lights originate from LED arrays of 2x6 to show 9 zones These zones are being indicated on the control panel also by Graphic Zone Leds Lo...

Page 10: ...adjustable warning tones Alarm Counter In Counter one way at 5 Digits Visible Invisible 4 Digit changeable PIN CODE optional Mechanic Lock Automatic Failure Display Reloading the Factory Default Setti...

Page 11: ...ellow red VU meter Environmental Magnetic Noise Level Display 10 different and 10 level adjustable warning tones Alarm Counter In Outgoing Counters separately at 5 Digits Visible Invisible Mechanical...

Page 12: ...for a specific weapon or test object fast consistent calibration SMART DETECTOR Graphic Zone Display Display of Metal Density at 10 level green yellow red VU meter Environment Magnetic Noise Level Dis...

Page 13: ...Outgoing Counters separately at 5 Digits Visible Invisible Mechanical Lock For Control Panel and 4 Digit changeable PIN CODE Automatic Failure Display Adjustable alarming duration 0 5sec 2secs Neglig...

Page 14: ...ensity at 10 level green yellow red VU meter Environment Magnetic Noise Level Detection Display 10 different and 10 level adjustable warning tones Alarm Counter In Outgoing Counters separately at 5 Di...

Page 15: ...electrical installation of the WTMD preferably from the ceiling or from the floor without moving or stepping on it Protect your WTMD from humidity and water since it is versatile electronic equipment...

Page 16: ...lts do not fully tighten at this stage 2 2 9 Remove the four hex bolts holding the base fixing plate at the bottom of each side panel using Allen key Note be careful to retain the hex bolts in a safe...

Page 17: ...IGHTS INDICATOR LCD DISPLAY screen RUN X SEL UP DOWN GRAFIC ZONE LEDs LOCATOR 3 1 1 LCD LIQUID CRYSTAL DISPLAY SCREEN The LCD is an ongoing visual display located in the overhead Control Unit The LCD...

Page 18: ...ON OFF BUTTON The ON OFF touchpad button turns on and off the WTMD When first switched on the WTMD initiates a self test for ten seconds during which time a test tone will be heard Please wait for 1...

Page 19: ...nergy after a certain period of time during power failure Graphic Display on Control Panel will indicate the location of threat zone 3 5 VARIOUS ALARMS Both the supervisor and the operator should be f...

Page 20: ...peripheral equipment such as CCTV Camera Turnstiles Gates etc CONTACTS PINS RJ11 12 220 VAC 0 5 Amps 24 VDC 2 Amps 1 NO 2 NO 3 Common 4 Common 5 NC 6 NC Contact numbers of the socket are coded as they...

Page 21: ...t of the user code by using the UP DOWN buttons Then press SEL If the correct code has been entered the display will change to show SECURITY LEVEL followed by the current security level set e g LEVEL...

Page 22: ...All channels except prefixed NC nilec channel can be aligned to different sensitivity levels Sensitivity levels vary from 000 max sensitivity to 245 min as in 246 steps Auto Designate Mode AD see 4 1...

Page 23: ...0 Security Level 8 080 Security Level 9 090 Security Level 10 100 Security Level 11 110 Security Level 12 120 Security Level 13 Security Level 14 Security Level 15 Security Level 16 Security Level 17...

Page 24: ...When sensitivity adjustments are complete other programming options may be accessed by pressing the UP DOWN buttons to select the required sub MENU or press RUN X to return to the normal operating mod...

Page 25: ...tic assignment according to the statement displayed Pass the objected metal through the WTMD with a person without any other metal object when the traffic light is green 3 Repeat the procedure in 2 3...

Page 26: ...number of alarms after reset This may be displayed from ALARM COUNTER ALARM COUNTER 000125 The alarm memory can be viewed or reset as follows 1 Press UP DOWN buttons from the MENU until ALARM COUNTER...

Page 27: ...thus return to the normal operating mode NOTE Please ask the alarmed people to walk back through the WTMD so that the in out counters wouldn t count the same person again and again This way the number...

Page 28: ...ttons to select either N display OFF or Y display ON 4 Press SEL button to select and fix the setting Press UP DOWN buttons to move to the next sub MENU option or press RUN X button to store the chang...

Page 29: ...way With this extra feature it is possible to delete this function To realize this PASS SNSR Y N 1 Find PASS SNSR sub MENU by UP DOWN buttons 2 Enter the MENU by pressing SEL button 3 Select your alte...

Page 30: ...ollow 4 1 6 above 4 Ensure persons only enter the gate way when the green pacing lights are illuminated 5 Finally if an alarm is generated refer to section 5 3 below 5 2 ROUTINE TESTS ThruScan should...

Page 31: ...9 zone areas In cases where there is more than one object the lights appear in each array that requires investigation This enables the operator to know from which area s objects require removal and to...

Page 32: ...etection for a prolonged period Error 17 Left Bottom Zone No Detection for a prolonged period Error 19 Right Bottom Zone No Detection for a prolonged period Error 26 Battery Power Supply failure for s...

Page 33: ...ts IP55 ThruScan is produced using materials meeting TSE and or TSEK norms if existing ThruScan is within the magnetic emission limits approved by FDA American Food Drug Administration It is certified...

Page 34: ...s side by side and without cable If the cable connection is maintained one of the WTMD operates as the main master unit and the other as the slave satellite For the synchronization of the units 1 Atta...

Page 35: ...t 7 9 Back fixing crosspiece 2 8 Back fixing crosspiece 2 8 Each side panel 16 Each side panel 19 Fixing apparatus 3 6 Fixing apparatus 3 6 Assembled weight 45 6 Assembled weight 52 3 Packaged weight...

Page 36: ...ion details see the SRC SCADA Remote Control Software Manual in Section 10 2 and mounting questions in section 9 2 ThruScan s3 s9 models are capable to control up to 16 WTMD units by one PC and cable...

Page 37: ...rea to be controlled Such as airports shopping centres military premises or jailhouses or military control points etc If more than one WTMD will be observed from one PC than please inform your dealer...

Page 38: ...nels from drizzled rain It is made of plastic material 7 3 BATTERY GROUP ThruScan operates for approximately 4 hours with its standard inbuilt uninterrupted power supply UPS with batteries It is possi...

Page 39: ...te to contact your dealer or our Company for any assistance 8 3 MODULE REPLACEMENT The system comprises a series of removable and replaceable modules that are tested and calibrated independently there...

Page 40: ...Mounting Questions 9 3 Operational Questions 9 1 FREQUENTLY ASKED QUESTIONS Is technical personnel necessary for the mounting of the WTMD Mounting and dismounting this WTMD is extremely easy The user...

Page 41: ...e moving metal Also the environmental conditions should match with the security class of your WTMD See section 2 1 Is it possible to have the mains input from Top to Bottom or Bottom to Top In general...

Page 42: ...uScan I want to operate my WTMD through a standard telephone line using the Remote Control SRC SCADASoftware How should I make the connection You may operate and or make the adjustments of your WTMD f...

Page 43: ...cable supplied by the factory you may have a data communication up to 100 meters It is possible to increase this distance up to 500 meters by using a thicknet coaxial cable RG 6 RG11 as well Please c...

Page 44: ...an extraordinary situation related with its usage In such cases the operating conditions of the WTMD should be checked and the technical service should be called See section 6 4 for the coded error a...

Page 45: ...ned throughout the world The Magnetic Field Strength of ThruScan appears much lower than have been stated by FDA With the VLF technology with its special Rx Tx coils design and programming which minim...

Page 46: ...index number 1 5 Select the Magnetic ThruScan s number from GATE NO window This will up date the complete information on your SCADA screen at your pc for the data of the selected walk thru STATUS wind...

Page 47: ...ror codes Telephone line disconnection displayed as READ ERROR but also the walk thru errors are displayed In Level Select window 20 security levels are existing of which NC NILECJ can not be changed...

Page 48: ...justments performed such as To shut off the alarm tone V To adjust the volume of alarm tone level increase decrease CH Security Level Adjustments increase decrease Counter Visibility on off Alarm Coun...

Page 49: ...at you hav assembled the apparatus properly The assembled WTMD should be carefully placed into the transportation accessory and then the item number h should be used to fix the accessory by screwing t...

Page 50: ...RAL the instrument has been used against the instructions stated in the user s manual your warranty has not been among our files by your request with Warranty In only ELEKTRAL A S is authorized to con...

Reviews: