manualshive.com logo in svg
background image

POWER

Internal Battery: 3V, Lithium.
Life expectancy:  5 years +.
Replacement Part:  36367-202.

BACKLIGHT

10-30 VDC @ 30 mA max.
(Derate operating temperature 1°C/Volt above 17VDC.)
Reverse polarity protected.

PHYSICAL

Operating Temperature:  -20° to 70°C.
Storage Temperature:  -20° to 70°C.
Operating Humidity:  60% Non-condensing.
Weight:  2.2 oz. net.
Display Size:  .43" high.
Front Panel Rating:  NEMA 4X when mounted with gasket
provided.
Case Material:  Cycolac X-17.

TOTALIZER

Type:  UP counting.
Digits:  8

COUNT ACCURACY

100% when operated within specifications.

DC COMMON (Terminal 1)

COUNT INPUTS
Input B (Terminal 2) Low speed input designed for contact
closures to DC common.

Speed:  0 to 20 Hz.
Min Low Time: 10 milliseconds.

Min High Time: 40 milliseconds.
Impedance:  101K ohm.
Voltage  Thresholds:

Low 0 to 0.4 VDC.
High 2.0 to 28 VDC.
Max High 28 VDC.

Input A (Terminal 3) High speed input requiring a voltage
source such as a current sourcing sensor or a current
sinking sensor used with the provided pull up resistors.

Speed: 0 to 10 kHz.
Min Low Time: 80 microseconds.
Min High Time:  20 microseconds.
(The above times are with a 0 to 5.0 V swing.)
Input Impedance:  2ký above 5 VDC.
Voltage  Thresholds:

Low 0 to 1.2 VDC.
High 2.0 to 28 VDC.
Max High 28 VDC.

RESET INPUT (Terminal 4) designed for contact closures to
DC common.

Min. Low:  0.25 to 1 sec. (reset is maintained).
The required pulse width varies with count speed, scale
factor and number of digits displayed.
Voltage  Thresholds:

 Low 0 to 0.4 VDC.
High 2.0 to 28 VDC.

FRONT PANEL RESET ENABLE (Terminal 5)

Operation:  Level sensitive (maintained).

Courier Models:

53300-400

Totalizer

53300-401

Totalizer, Extended Temperature Range

53302-400

Totalizer with Backlight

Durant

INSTALLATION AND OPERATION

MANUAL NUMBER  53300-900-08

Recommended 

Panel Cutout

2.95" (74.93mm)

1.57" 

(39.87mm)

1.25" 

(31.75mm)

2.677" (68mm)

1.299" 

(33mm)

RESET

Durant®

®

Durant

Содержание Durant Courier Series

Страница 1: ...put A Terminal 3 High speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz Min Low Time 80 microseconds Min High Time 20 microseconds The above times are with a 0 to 5 0 V swing Input Impedance 2ký above 5 VDC Voltage Thresholds Low 0 to 1 2 VDC High 2 0 to 28 VDC Max High 28 VDC RESET INPUT ...

Страница 2: ...wn to common When a sensor output supplies voltage to this terminal one count is regis tered on the display The sourcing signal must supply at least 1 0VDC but no more than 28VDC Note When a sourcing signal is applied to terminal 3 a power assist feature of the Courier extends the life of the battery Terminal 2 is the low speed current sinking count input designed to be used with a contact closure...

Страница 3: ...ht Display 3 WIRINGDIAGRAMS CONTACT CLOSURE COUNT INPUT FRONTPANELRESETENABLE BACKLIGHTWIRING 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC REMOTERESET 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC Current Sinking Sensor 6 to 28 VDC 1 5ký SOLID STATE INPUT CURRENT SINKING SENSOR 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC...

Страница 4: ...ERDAMAGESWHETHERDIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL OR SPECIAL OR FOR ANY EXPENSES INCURRED BY REASON OF THE USE OR MISUSE SALE OR FABRICATION OF PROD UCTS WHICH DO OR DO NOT CONFORM TO THE TERMS AND CONDI TIONS OF THIS CONTRACT INDEMNIFICATION Buyer agrees to hold Eaton harmless from defend and indemnify Eaton against damages claims and expenses arising out of subsequent sales of Durant pr...

Отзывы: