Page 1: ...USER S MANUAL MODEL...

Page 2: ...to avoid breathing gas Arc radiation harmful to your eyes and burn your skin Use suitable helmet and light filter wear protective garment to protect eyes and body Use suitable helmet or curtain to pro...

Page 3: ...a arc It has the functions of arc initiation current arc stop current welding current basic value current current ascending time current descending time gas delay time continuous adjustment What s mor...

Page 4: ...utput voltage V 104 112 120 144 Duty cycle 60 60 60 60 Efficiency 85 85 85 85 Power factor 0 93 0 93 0 93 0 93 Insulation grade F F F F Housing Protection grade IP21 IP21 IP21 IP21 Arcing Way Untouche...

Page 5: ...e and compressed air source and use hoop and other way to tighten the joint Air source should supply suitable pressure flow and be dry If your air source does not meet the above requirements you shoul...

Page 6: ...Make sure power voltage is inside the waved range Output cable connection 1 Make sure tube of pressed air is connected to copper connector by high pressure rubber tube firmly 2 Make sure copper screw...

Page 7: ...osition 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put...

Page 8: ...Press the control knob of torch electromagnetic valve is starting sound of HF arc striking can be heard and burner of torch should flow out gas Burner of arc supporting cutter should spurt fire 4 It i...

Page 9: ...result current and air pressure must be matched well So when the current is set the pressure and flow must be adjusted suitably If the air flow is too big and cooling effect is too strong it will caus...

Page 10: ...of environment User should make sure the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to...

Page 11: ...ow and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value When voltage i...

Page 12: ...d steam enter into inter machine if they enter into machine please dry inter machine then check insulation of machine 5 If welding machine will not be operated long time it must be put into packing bo...

Page 13: ...ken or switch broken 3 Control circuit is broken Contact factory Abnormal indicator is lit Meter is normal Fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Rectifier broken 4 Control...