background image

e2-Live Home Automation   

Edit by Amos /20150810 

0

 

 

 

 

 

RP-20F AVhome BOX 

 

Instruction manual 

 

 

 

 

 

Summary of Contents for AVhome BOX

Page 1: ...e2 Live Home Automation Edit by Amos 20150810 0 RP 20F AVhome BOX Instruction manual ...

Page 2: ...t to PC 12 Install USB driver 12 RP 20 SOFTWARE 15 CONNECTION 15 FUNCTIONS 1616 ID setting 1616 Setting ID of iPower PS 301or PS 302 17 IR LEARNING 18 Preparation before operation 18 Start to learning IR signal 18 Situation of need to re learning 20 Leave learning mode 21 SCENARIO SETTING 23 Edit lighting curtain 23 Home Appliances 24 Scenario tool 25 Clearn up memory 25 Save 26 Operation with iPo...

Page 3: ...10 2 Version Description Date Ver Revised contents Software Version 20130709 REV 1 2 Prototype 070803 2013 7 16 REV 1 2 Prototype 071002 2013 07 18 REV 1 2 Prototype 071805 2013 07 23 REV 1 2 Prototype 071805 2013 10 29 REV 1 5 Formal ver 102902 ...

Page 4: ...ting areas each with 12 buttons include ON OFF ALL ON ALL OFF 10 100 dimmer 1 area of curtain control with specifies the brand 24 sets of scenarios Backup IR learning code and also scenario setting data could restore all setting parameters The following operation system is available Windows XP Windows 7 32 64 bits Windows 8 32 64 bits Functions Type RP 05 RP 10N RP 20F Numbers of IR button 29 butt...

Page 5: ...ssion and received indicator IR emission point 2 7 can be extended to the front window of appliances for individual control USB socket connected to computer Main power input please make sure use the suitable specification of 5V 1 2A please take the original packaging adaptor to avoid damage occur Power current ability less than 1 2A will cause IR operation incorrect No 1 Wiring IR extended emissio...

Page 6: ...e2 Live Home Automation Edit by Amos 20150810 5 Accessary Extended IR emit wire X 2 1 8m USB connector wire to PC DC Adaptor 5V 1 2A CD catalogue instruction manual Double side adhesive X 6 pieces ...

Page 7: ...ared LED has 360 degree emit to control whole of home appliances of open space in the same room IR emission distances 15 meters maximum left right 15 degree fine tune In case of glass IR refraction may beyond the control range but you can fine tune the direction of the LED to come into the control range therefor before installation suggest to find out all of the location of your appliances then ch...

Page 8: ...roller of e2 Live such as RC 09 itouch VC 1500 Consistent with previous operating mode HT 100 RP 20 software etc select the device TV DVD first then press Power CH CH After RP 20 received all of the IR emitor will emission at the same time no need to specify a fixed point The conditions of single point emission are There are two same brand device in same space in order to avoid action together it ...

Page 9: ...he air condition of living room master bedroom Learning IR signal of your air condition onto the button of A C Use top open IR to remote the air condition in the living room Put point 1 wiring IR to reach your master bedroom to control your second air condition If you want to control both of your air condition you can use all emission output RP 20 package provides two IR infrared emission lines co...

Page 10: ...ording to the installation environment make sure which device need to be individual control and with the matching use of hardware and software The following for the above mentioned current e2 Live system provide individual operator interface will be described Use the software of RP 20F need to connect to PC Use RC 09 smart controller 1st press device example 2nd press then all of the IR emit at th...

Page 11: ...h use with PC 09W or PC 09I Wi Fi emission Operation same as RC 09 Select device first example 2nd press then all points of IR emit Select device first example 2 nd press 3 rd press then point 1 emit Select device first example 2nd press 3rd press then point 2 emit Select device first example 2nd press 3rd press then point 3 emit Point 2 emit Same as RC 09 number 11 Point 3 same as RC 09 Number 12...

Page 12: ...ring installation the program may ask you to download the update system of framework Each computer may have different necessary please make sure your PC can be connected to network RP 20F will install necessary program automatically Click Install Installing RP 20 takes very short time to install After completed install RP 20 will auto open See the software is opened means that the installation is ...

Page 13: ...is completed installed in a fixed location Please use the power adapter attached with the package to ensure that the operation of RF and IR transmitter function properly Install USB driver Connect USB wire to PC on the screen of right down angle of the PC will show that had automatically found the device of RP 20 USB x If the computer does not have a suitable driver the follow message will appear ...

Page 14: ... is not properly enabled it can not be connected If you have any of the above circumstances occur which means that you need to install RP 20F USB driver manually take the CD out of the package insert into the CD slot click USB driver to install With an exclamation point which means that the device can not be used you need to install the driver ...

Page 15: ... COM Please go to Device Manager to confirm the correct position of the COM in order to successfully communicate with RP 20 目前 RP 20 取 得的連線 COM 位 Please choose the same COM position for RP 20 Click DETECT currently there are actually connected to RP 2 its software will connect based on hardware COM position If there is only one COM position or you had selected the clearly known one then you can pr...

Page 16: ...20 with PC then COM port will be detected Home page setting If RP 20 AVhome Box had been connected to PC then press Detect to automatically find out the connection of COM port If unconnect If you can not successfully connect please re plug USB connector of RP 20 and re open the software automatically to execute the detect again ...

Page 17: ...0000 9999 When enter impleted 4 digital numbers it will be field with 0 in front of your input numbers such as input 123 the actual ID would be 0123 input 66 would be 0066 When writing success RP 20 AVhome Box will prompt buzzer and LED buzzer short Bi 4 times LED Red flash 2 times Here will display the instructions ...

Page 18: ...ch as TV CD DVD iPower s red LED will flash it means received your command and completed setting Use this For setting ID code please click the corresponding button of appliances which was plugged into the iPower r Quick flash indicate successful ID setting If tgere isn t any flash display please repeat steps 1 3 Press and hold this button Poke a button in setting hole LED solid red waite for setti...

Page 19: ...our remote controller can be seen that means the emission of remote controller is in normal situation z Firstly planning useful remote keys of appliances for example TV to the correspondent button on RP 20 Start to learn IR signals 1 Press Start Learning button to enable right side buttons function 2 Press the button which to be learned of the device Such as TV the following 29 action buttons will...

Page 20: ...n then press down the power button to input power ON OFF code Attention means into learning mode 29 action button will enable the buttons to have the function of press Buzzer Short Bi LED Flash Blue LED Buzzer Short Bi LED Blue LED flashed and then stable on IR in Please alignment here with your remote controller of appliances Use your home appliance s remote to input button signal ...

Page 21: ...e learning has failed please contact your dealer for help Press Start learning then you can select any one of the following devices to get into remote code learning Note After you came into learning mode if you don t action within 15 seconds RP 20 will leave out the learning mode Beep of buzzer RP 20 will enable the button of Start Learn Press again into learning mode once more Buzzer Short Bi thr...

Page 22: ... will leave learning mode automatiically When completed all learning action suggest to operate again all of the buttons of RP 20 for confirm all learning are successfully Please switch to the following screen Control ValidationÆInfrared Appliances Check Operation Bizzer One long Bi two hort Bi LED Red LED flashed twice and turn off Blue LED flash andfinally distinguish Start Learing recovery means...

Page 23: ... Select All emit 3 Press the right action key 4 Make sure the corresponding buttons are successfully remote control if there is not please repeat the learning sequence RP 20 can specify a different signal IR emitting region If you just want to verify that learning is successful select All emit ...

Page 24: ... Macros ID can be specify difference with RP 20 to corresponding lighting curtain and iPower Please note that in use of any remote control device operation remote controller ID must same as RP 20 not same as scenario Devices Light 01 Light 02 Light 03 Light 04 Light 05 Curttain specify Keys 01 12 Actions Lighting ON OFF ALL ON ALL OFF ...

Page 25: ...20 if setting none detect the interval time still working for example TV Power still ON and 10 seconds interval if the power been detected ON will perform 10 seconds interval before next action 7 appliances can be choose IR emission location 1 7 ALL Appliances 29 action If choose power then must select the status of electric power detection Using iPower to detect appliance power scosumption accord...

Page 26: ...the bottom of the list Select and move edited data up and down for smooth scenario control Recovery a previous action you can always forward recovery Click to delete a selected single data row Save the current page of single scenario setting Save all 24 scenario setting will take a little time please be attention to see front RxTx red LED Stop flash means save compled Still flashing means saving i...

Page 27: ...eration with iPower 1 Plugs appliances into iPower such as TV DVD CD 2 Use RP 20 to setting the location of remote control refer to p4 3 Fine tune every detection of home appliancesons on ipower to make sure correct detection please refer to iPower menu 4 Use RP 20 software scenario edit power current detection defined Content of scenario edit TV must to open TV Still power ON During perform scena...

Page 28: ...f the operation Also need special attention to several important functions when editing a scenario in order to ensure actually perform the operation of scenarios 1 RP 20 porovide 7 zones of IR individual emission with 2 to 6 points of wiring type IR please make sure the wire is connected to correspondent device for correct remote control 2 RP 20 provides intelligent power sockets combined with iPo...

Page 29: ...test immediately to make sure your setting is correct and adjust instantly Scenario remote controller You can also use the following remote controllers to perform the following actions scenarios Link to other scenario control RC 09 smart controller Scenario 1 10 HT 100 LCD Controller Scenario 1 24 PC 09W I APP software Scenario1 24 Macro controller 2 6 buttons LC X0T Gang box MS X0T Wall mount Sce...

Page 30: ...vide remote control of lighting and curtain it could be remote control all function of e2 Live via this software In operation the network connections of RP 20 or PC must be maintained Lighting Curtain Guided operation buttons select device in sequenceÆLocationÆDimmer ON OFF Dimmer switch only ALL ON ALL OFF is for 1st 5th areas ALL ON ALL OFF curtain control is operated with specify brand 1 2 2 3 ...

Page 31: ...es Infrared control Select device ÆIR emission location ÆAction button Scenario verifications Press button of scenario 01 24 RP 20 will be executed immediately be careful to operate during operation of scenario it does not accept others remote commands again ...

Page 32: ...ckup or recovery are as follow 1 Remote ID 2 Infrared learning data 3 RP 20 AVhome Box scenario settings Its takes about 2 or 3 minutes to backup or recovery Do not remove the USB connection in process of backup or recovery to avoid error reading or wrighting Press The default storage path suggest do not changed File names can be modified in either Chinese or English ...

Page 33: ...nother RP 20 Recovery ID Scenario For RP 20 software setting is finished Scenario ID data You can save as a file to PC RP 20 can save a single or all of the scenarios to PC for storage and read back to RP 20 by Input Purpose of output data of scenario 1 Save for backup file 2 For the purpose of revise current setting data of RP 20 to reduce re setting time ...

Page 34: ...In IR learning RP 20 is recommended to open the buzzer can help confirm the operation action Output Save the current scenario settings to PC for later revised using could be one or more Press The default storage path suggest keep the path File names can be modified in either Open Close ...

Page 35: ...t settings you can choose to turn off the buzzer About Restore factory settings Press and then IR learning data and scenario setting will be cleare Please be sure to confirm before execution ID will be retained so if you need to change the ID please use the Home page s ID settings to re write ID Buzzer Long Bi Software Version ...

Page 36: ...ith the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following...

Reviews: