9100SXT

Meter Initiated Water Softener

OPERATION MANUAL

54746     2/09

PLEASE NOTE: On page nine of this manual you will find important maintenance procedures for
the continued proper operation of your unit. These MUST be performed regularly for your
guarantee to remain valid. 

Summary of Contents for 9100SXT

Page 1: ...ener OPERATION MANUAL 54746 2 09 PLEASE NOTE On page nine of this manual you will find important maintenance procedures for the continued proper operation of your unit These MUST be performed regularly for your guarantee to remain valid ...

Page 2: ...ompleted the valve will return to Service and resume normal operation Example Less than 6 minutes remaining in Regen Step Rapid Rinse Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step position and resume normal step timing 1 5 Performance PM Indicator Flow Indicator Flashing with water flow PM Indicator Flow Indicator Flashing with...

Page 3: ... the system on a timed interval The control will initiate a regeneration cycle at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day override value Day of the Week Control This control regenerates the system on a weekly schedule The schedule is defined in Master Programming by setting each day to either off or on The control will initia...

Page 4: ...O ring to ease installation of the riser tube DO NOT use petroleum based lubricants as they will cause swelling of O ring seals The softener or filter is now charged with softening resin It is recommended that the softener or filter tank now be completely filled with water SLOWLY to soak the resin or filtration media before startup This will allow the media to absorb water as well as help displace...

Page 5: ...to the tank to speed up the filling but the valve should be in the Brine Refill position for a minimum of two minutes to purge the air out of the injector set 10 Press the extra cycle button to advance the valve from the Brine Fill position through service to the 2 position Brine Rinse position Verify that water is being drawn from the tank If not repeat step 9 11 Press the extra cycle button to a...

Page 6: ...nd hold either the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD 2 Adjust the displayed time with the Up and Down buttons 3 When the desired time is set press the Extra Cycle button to resume normal operation The unit will also return to normal operation after 5 seconds if no buttons are pressed Queueing a Regeneration 1 Press the Extra ...

Page 7: ...ps 1 Press the Up and Down buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen THIS IS AN OPTION ONLY PLEASE DO NOT ADJUST BEFORE CONSULTING AN AUTHORIZED DEALER 3 Press the Extra Cycle button Use this display to adjust the Feed Water Ha...

Page 8: ...st regeneration All individual settings d1 d2 d3 d4 d5 d6 d7 are set to 0 Control board memory failure Unplug the unit from the power source When power is restored to the unit the Err _ display code clears If the condition causing the error has not been resolved the Err _ code reappears in the four digit display Do not attempt to troubleshoot this problem any further Regeneration must occur for th...

Page 9: ...d be performed when little or no water will be used in the household Safety Float The brine tank is equipped with a safety float which prevents your brine tank from over filling as a result of a malfunction such as a power failure Water Pressure Your softener is designed to operated under normal water pressures from 20 psi 1 4 atm to 100 psi 8 2 atm New Sounds You may notice new sounds as your wat...

Page 10: ...of Your Softener To retain the attractive appearance of your new water softener clean occasionally with a mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your softener to freezing or to temperatures above 110 F 43 C Cleaning the Injector Assembly Figure 7 Sediment salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this...

Page 11: ...ir eliminator control Check for dry well condition Drain line flow control is too large Ensure drain line flow control is sized 6 IRON IN CONDITIONED WATER Fouled resin bed Check backwash brine draw and brine tank fill Increase frequency of regeneration Increase backwash time Iron content exceeds recommended parameters Add iron removal filter system 7 EXCESSIVE WATER IN BRINE TANK Plugged drain li...

Page 12: ...l be from the date thereof Lifetime Guarantee on Mineral Tanks and Brine Tanks WaterGroup Companies Inc will provide a replacement mineral tank or brine tank to any original equipment purchaser in possesion of a tank that fails within his her lifetime provided that the water conditioner is at all times operated in accordance with specifications and not subject to freezing General Provisions WaterG...