manualshive.com logo in svg
background image

 

 

 

 

 

OPERATI

NG MA

NUAL

 

Содержание DuraSprayer

Страница 1: ...OPERATING MANUAL ...

Страница 2: ......

Страница 3: ...ged aerosol products Its handy size and professional appearance make it a valuable tool for both residential and light commercial accounts In addition it gives you the flexibility of using a variety of disinfectants that are EPA approved for use in this type of equipment This system combines the right amount of disinfectant with a high volume of moderately pressurized air to improve penetration th...

Страница 4: ...age 11 PARTS AND SERVICE Page 14 EQUIPMENT SPECIFICATIONS Page 15 WAND Parts detailed Page 16 Item s Product Codes and Descriptions Page 17 CABINET Parts detailed Page 18 Item s Product Codes and Descriptions Page 19 Parts detailed Cont d Page 20 Item s Product Codes and Descriptions Cont d Page 21 ...

Страница 5: ...wear protective clothing eyewear chemical resistant rubber gloves and a respirator Refer to the disinfectant label for specific instructions and other precautions 2 Preparations and Guidelines when Making ULV Aerosol Applications Refer to disinfectant label for directions on proper preparation for area to be treated before operating this equipment General preparation includes Everyone in the treat...

Страница 6: ... placed in containers that will prevent contact with the disinfectant Food preparation utensils and surfaces must be covered or cleaned thoroughly before reuse Close and lock all entry ways Professionals may want to consider posting warning signs on doors opening into the treatment site Open all doors cabinets storage areas and drawers in the treatment area Before reoccupation thoroughly ventilate...

Страница 7: ...e Red Tip Protector Cap Switch the unit to the ON position using the Toggle Switch on top of unit 6 Adjust Regulator To adjust regulator start by unlocking the safety lock located on the adjustment knob by pulling up on the knob If a red ring is present lift up on the red ring to unlock Turn the knob slowly clockwise until the 0 30 psi back mount gauge reads 10 12 psi Note The higher the pressure ...

Страница 8: ...mosphere at the tip Next the air flows into the regulator which controls the pressure exerted on the liquid inside the tank The liquid product then travels through the second line of the twin tubing to the wand 9 Apply disinfectant Observe Label Directions Do not operate the DuraSprayer with disinfectants that are not labeled for aerosol fog or mist applications Read the disinfectant label to dete...

Страница 9: ...h the already applied disinfectant into deep hard to reach areas When performed properly this technique improves penetration and reaches target areas more effectively using less disinfectant than required by other techniques Helpful Hints Occasionally when working overhead the pressure exerted on the liquid tank by the regulator will not be sufficient to drive the liquid 8 10 feet above floor leve...

Страница 10: ...rew fill cap by turning counter clockwise and remove E Holding the wand over the tank place gloved finger over integrated stainless crack crevice tip exit orifice stopping the flow of air then squeeze the application trigger until liquid is purged from the wand and hose Page 6 required The aerosols that you ve probably used in the past were driven by propellant Therefore you saw larger particles a...

Страница 11: ...g the Tank Drain the DuraSprayer tank when changing disinfectants or storing for an extended period of time The unique pour dry design of the tank allows you to remove all materials from the tank by simply tilting the unit over a funnel and returning the product to its original container A Follow instructions to properly backflush unit B Remove the Drop in Tank Filter C With the side closest to th...

Страница 12: ...d be able to hear and feel air flowing from the tip of the wand E Check for liquid flow with no air flow Turn unit off leave pressure in the tank point the wand into the original disinfectant container and depress the trigger until a pin stream flows from the tip If a pin stream flows from the tip with the compressor off and the tank under pressure Remove integrated crack crevice tip Exit orifice ...

Страница 13: ...r until aerosol flows consistently without interruption Another method is to turn off the compressor and point tip into original disinfectant container and squeeze trigger to produce a pin stream Allow to flow until uninterrupted B Teflon seat may be damaged or contain debris preventing positive shutoff First follow instructions for step number 11 of operating instructions to backflush liquid Remo...

Страница 14: ... over head air is flowing from the tip but no chemical aerosol is being produced A higher liquid pressure is necessary when wand is higher than 6 from unit To compensate simply adjust regulator clockwise in one or two psi increments until desired flow is reached Note When returning to ground level operations reduce pressure by turning regulator counter clockwise and releasing pressure from the tan...

Страница 15: ...ons Do not operate the DuraSprayer with disinfectants that are not labeled for aerosol fog or mist applications Read the disinfectant label to determine if the disinfectant is EPA approved for use in this type of equipment Contact your chosen distributor for information on disinfectants currently labeled for use in equipment such as the DuraSprayer 3 Preparations and Guidelines when Making ULV Aer...

Страница 16: ...ts including exotic pets birds amphibians reptiles arachnids must be removed Re entry for exotic pets is not recommended for a period of 24 hours All exposed food must be removed or placed in containers that will prevent contact with the disinfectant Food preparation utensils and surfaces must be covered or cleaned thoroughly before reuse Close and lock all entry ways Professionals may want to con...

Страница 17: ...ace the unit in a plastic bag before adding materials to carton Ship the unit with a description of the problem a contact name and phone number and a return shipping address to Duraline Systems Inc 39 Western Highway West Nyack NY 10994 NOTE Post Warranty service will be billed for parts labor packaging if needed and freight HINT Be sure to save your original factory packaging for future use Shoul...

Страница 18: ...0 Weight empty 16 lbs Weight full 17 5 lbs Shipping Weight 21 lbs Tank Capacity 28 oz Only fill to 20 oz Operating Pressure air 20 psi Operating Pressure liquid 9 20 psi Motor 110 v AC 60 Hz 2 5 amps 275 watts 115 v AC 60 Hz 2 6 amps 299 watts Compressor Type Diaphragm ...

Страница 19: ...Page 15 DuraSprayer Wand 12 or 18 ...

Страница 20: ... Support 15 8010015 Strainer Housing 16 8010016 Teflon Packing 17 8010017 Packing Screw 18 8010018 Lock Nut 19 8010019 Brass Nut 20 500019 Inlet Hose Shank 21 8010020 Screw Housing 22 8010021 Screw 23 8010022 Steel Trigger 24 300023 Stem Sub Assembly 25 300024 Spring Type 302 2 26 300026 Stainless Airline for Wand 27 300027 Snap Ring 28 300028 Safety Lock Screw 29 8010049 1 8 Ferruless Tube Fittin...

Страница 21: ...Page 17 DuraSprayer Details ...

Страница 22: ...10041 1 8 Female Tee 47 8010042 0 30 Panel Mount Gauge 48 8010043 1 8 Regulator 49 8020044 1 8 Viton Check Valve 50 8010045 1 8 Street Elbow 51 300046 Poly Grommet 52 8010047 15 Red Twin Coiled Tubing 300039 15 Black Twin Coiled Tubing 300132 15 Blue Twin Coiled Tubing 53 300048 Threaded Ported Tank Cap 55 8010051 Electrical On Off Switch 56 8010052 Spring Clamp for Wand 57 8010060 Handle 58 80100...

Страница 23: ...Page 19 DuraSprayer Details ...

Страница 24: ...mplete 76 300088 10 32 X 3 8 Flat PHL MS Not Shown 77 300089 10 32 Stopnut Not Shown 78 300090 3 8 X 1 2 Socket Head Cap Screw 79 300091 3 8 Starwasher 80 300092 Wire 16g Not Shown 81 300094 Unit Sticker Not Shown 82 300095 IMPORTANT Sticker Not Shown 83 300098 1 8 NPT X 1 8 HB 90 84 300099 1 8 NPT X 1 8 HB 85 300082 1 4 Nylon Compression Sleeve Not Shown 86 8010058 Insulated Ground Wire Connector...

Страница 25: ...y other warranty or assume obligation or liability on Duraline Systems Inc s behalf Duraline Systems Inc shall not be liable for any labor damage or other expense nor Duraline Systems Inc be liable for any indirect incidental or consequential damages of any kind incurred by the reason of the use or sale of any defective product or part Return Policy All units must be flushed of any chemicals befor...

Страница 26: ......

Страница 27: ......

Страница 28: ...Duraline Systems Inc 39 Western Highway West Nyack NY 10994 877 561 0500 Phone 845 353 2095 Fax www duralinesystems com Copyright 2015 Duraline Systems Inc ...

Отзывы: