background image

Compliant with norm NF EN 1004

 

 

Compliant with Decree dating form 01/09/04 

HEAD OFFICE 

 

Route de la Limouzinière - BP 41 
44310 St PHILBERT DE GRAND LIEU 
Phone: 02 40 78 97 22 
Fax: 02 40 78 78 71 
www.duarib.fr 
Mail: [email protected]

 

D040369B 

C0400227B 

ASSEMBLY,  

DISASSEMBLY AND 

USE INSTRUCTIONS

 

 

R O L L I N G   S C A F F O L D I N G S    

Содержание Altitude 150

Страница 1: ...orm 01 09 04 HEAD OFFICE Route de la Limouzinière BP 41 44310 St PHILBERT DE GRAND LIEU Phone 02 40 78 97 22 Fax 02 40 78 78 71 www duarib fr Mail welcome duarib fr D040369B C0400227B ASSEMBLY DISASSEMBLY AND USE INSTRUCTIONS R O L L I N G S C A F F O L D I N G S ...

Страница 2: ...8 500805 4 8 m 6 8 m Class 3 86 Kg 1 2 1 376016602064 5 376016602011 9 376016602058 4 376016602013 3 376016602014 0 376016602015 7 Gencod NF EN 1004 4 8 m floor height 3 8 m floor height 2 8 m floor height 1 8 m floor height LOADING CONDITIONS Floor Maximum allowed load spread over the floor 150 kg Whole scaffolding Maximum allowed load spread over the floors 300 kg class 3 200 Kg m spread load 50...

Страница 3: ...measurement mm C257005 C257003 C257008 11307 C257010 C257009 C257001 C257012 C257004 Head Office Route de la Limouzinière 44310 St Philbert de Grand Lieu EN1004 3 4 8 4 8 XXXD Rolling Follow the assembly and use instructions 08067 Page 3 20 D040369B Overall C Reference to the norm Load evenly spread class class 3 200 Kg m Maximum outdoor height use Maximum indoor height use Access via stairs no Ac...

Страница 4: ...0 62m ladder 3 5 1 2 3 C257004 1m x 0 62m ladder 1 8 2 C257005 1 5 m handrail 1 2 2 4 11307 1 5m wide alu wood floor with integrated toeboards 13 1 C257008 Brace s Lg 2m 0 8 2 2 4 4 C257009 Stabilizer 3 7 4 C257010 Pin bundle w 2 pins 0 05 4 1 2 3 Parcel weight 36 Kg 17 8 Kg 5 2 Kg 10 4 Kg 14 Kg C257012 C257003 Page 4 20 C257004 C257001 C257010 C257009 11307 C257005 C257008 D040369B ...

Страница 5: ... m 8 9 m Class 3 150 Kg 1 3 1 1 376016602070 6 500818 7 9 m 9 9 m Class 3 154 Kg 1 3 2 376016602071 3 376016602016 4 376016602059 1 376016602018 8 376016602019 5 376016602020 1 Gencod NF EN 1004 LOADING CONDITIONS Floor Maximum allowed load spread over the floor 205 kg Whole scaffolding Maximum allowed load spread over the floors 500 kg class 3 200 Kg m spread load 500812 500813 500814 500818 Safe...

Страница 6: ...16 5 9 m 3580 3260 2100 2000 690 790 500817 6 9 m 3560 3680 2100 2000 690 790 500818 7 9 m 4060 4220 2100 2000 690 790 Unit of measurement mm C257104 C257108 C257103 11308 C257105 Head Office Route de la Limouzinière 44310 St Philbert de Grand Lieu EN1004 3 7 9 7 9 XXXD Rolling Follow the assembly and use instructions 08068 Page 6 20 D040369B Reference to the norm Load evenly spread class class 3 ...

Страница 7: ...257103 2m x 0 69m ladder 4 7 1 2 3 C257104 1m x 0 69m ladder 2 4 2 C257105 2 m handrail 1 4 2 4 11308 2m wide alu wood floor with integrated toeboards 17 4 1 C257108 Brace s Lg 2 4m 1 2 2 4 4 C257009 Stabilizer s Lg 2 476m 3 7 4 C257010 Pin bundle w 2 pins 0 05 4 1 2 3 Parcel weight 48 3 Kg 23 Kg 6 8 Kg 13 6 Kg 18 4 Kg C257112 C257103 Page 7 20 C257104 C257101 C257010 C257009 11308 C257105 C257108...

Страница 8: ... m Class 3 78 Kg 1 1 376016602072 0 500823 2 9 m 4 9 m Class 3 86 Kg 1 1 1 376016602073 7 500824 3 9 m 5 9 m Class 3 122 Kg 1 2 1 376016602074 4 500825 4 9 m 6 9 m Class 3 127 Kg 1 2 1 376016602075 1 500826 5 9 m 7 9 m Class 3 134 Kg 1 2 1 1 376016602076 8 500827 6 9 m 8 9 m Class 3 170 Kg 1 3 1 1 376016602077 5 500828 7 9 m 9 9 m Class 3 175 Kg 1 3 2 376016602078 2 376016602021 8 376016602060 7 3...

Страница 9: ...F Code 1 9 m 2360 1400 2100 2000 690 790 500822 2 9 m 2820 2020 2100 2000 690 790 500823 3 9 m 2740 2240 2100 2000 690 790 500824 4 9 m 3140 2800 2100 2000 690 790 500825 500826 5 9 m 3460 3420 2100 2000 690 790 500827 6 9 m 3400 3840 2100 2000 690 790 500828 7 9 m 3860 4400 2100 2000 690 790 Unit of measurement mm D040369B Reference to the norm Load evenly spread class class 3 200 Kg m Maximum ou...

Страница 10: ...03 2m x 0 69m ladder 4 7 1 2 3 C257104 1m x 0 69m ladder 2 4 2 C257205 2 5 m handrail 1 9 2 4 11309 2 5m wide alu wood floor with integrated toeboards 20 4 1 C257208 Brace s Lg 2 8m 1 5 2 2 4 4 C257009 Stabilizer s Lg 2 476m 3 7 4 C257010 Pin bundle w 2 pins 0 05 4 1 2 3 Parcel weight 50 3 Kg 28 Kg 7 8 Kg 15 6 Kg 20 4 Kg C257112 C257103 Page 10 20 C257104 C257101 C257010 C257009 11309 C257205 C257...

Страница 11: ... first by moving the handrail back then by moving up and joint in the other end Handrail safe assembly Repeat this step to safely set the upper level handrails 1 2 3 4 With the brace close the lock at the end of the handrail on the rung with a small movement downwards You will close the second lock of the handrail when access to the upper level is possible Page 11 20 Diag 1 Diag 2 DUARIB PATENT D0...

Страница 12: ... floor at a higher position is done by moving each end of the floor one after the other until you have reached the desired height 2 3 4 Set a floor about six feet off the ground leaving the floor s locks open Page 12 20 DUARIB PATENT D040369B The floor s hooks allow for a difference of one rung maximum ...

Страница 13: ...ontact with the ground 3 Set two 2m ladders Pin both ladders Set up 4 handrails from the ground by following the safe handrail assembly instructions Brace s lock position closed Spirit level Page 13 20 Mark Description Qty 1 Ø25 bent pipe 1 2 Plastic pipe cap 2 3 Open stirrup 1 4 M8 wing nut connector 1 5 U shaped stirrup 2 6 H M8 brake nut 4 3 5 4 6 1 2 The first bent step must be set only on one...

Страница 14: ... lock two braces 6 Set two 1m ladders Pin both ladders With the help of a brace set four handrails for the upper level by following the handrail s safe assembly instructions Set the first floor up Close the two locks at each end of the floor s hooks Page 14 20 D040369B ...

Страница 15: ...7 Set the floor for the upper level Lock the floor 8 Go up on the floor Close the locks of all four handrails Set both handrails Page 15 20 D040369B ...

Страница 16: ...affolding can fit through a 0 7m width x 1 93 height door The Altitude 200 and 250 scaffoldings can fit through a 0 8m width x 1 93 height door In this setup you can transport your hardware and small tools Page 16 20 Assembly for transport and to fit through doors D040369B ...

Страница 17: ...the wind exceeds 45 kmph it is forbidden to use the scaffolding even if it is anchored Page 17 20 With a wind speed superior to 45 kmph it is mandatory to either disassemble or anchor it at the top If you chose to anchor it Set the stabilizers according to the below picture Add 2 anchors at the top Anchors not included in the parcel Anchoring kit code 20865 Superior to 45 kmph D040369B ...

Страница 18: ...bilizers according to the below picture Add 2 support bars on the upper end one on each vertical upright Supporting bars not included in the parcels Supporting bars must always be set above the stabilizer s upper attachment point When working on the front of the building use stabilizers and add 2 support bars Supporting bar set up zone OK Page 18 20 D040369B ...

Страница 19: ... end of the day by anchoring it or disassembling it Beware of turbulences when near the angle of a building or under a porch All 4 wheels must always touch the ground in order to support the work load and the structure s own weight Maximum load on one wheel 125 kg Make sure that support points can bear the load on the ground and that contact surface is properly calculated according to the ground s...

Страница 20: ...ess Anchor the scaffolding on the top part at the end of each operation Horizontal forces must not exceed 30 kg on the last floor level According to the current regulation the space between two floors cannot exceed 3m Maximum force 30kg MAINTENANCE Before any assembly or use you must check all the parts of the scaffolding to see if any could be defective and replace it if necessary You must make s...

Отзывы: