background image

07-01810A 2012-10 Warranty 07-00424 

Dri-Eaz Products, Inc. 

Owner’s Manual 

Dragon Mobile Furnace 

Model F507 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030  Fax: 360-757-7950 

www.Dri-Eaz.com

  

 

The Dragon Mobile Furnace is an indirect fired furnace providing heated air for water damage restoration, 

structural drying, construction, event shelters and other temporary heating applications. 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

 

Safety Information 

Read this document carefully to learn how to properly 
operate and service your Dragon Mobile Furnace. This 
manual should be kept with the unit and remain with the 
Dragon for the life of the product.  
 
 
 
 
 
 
 

 
 
 
 

WARNING! Do not alter or modify your Dragon in 
any way. Use only replacement parts authorized by 
Dri-Eaz Products, Inc. Modifications or use of 
unapproved parts could create a hazard and will 
void your warranty. Contact your authorized Dri-Eaz 
distributor for assistance. 
 
WARNING! Failure to comply with the instructions 
and precautions provided in this Owner’s Manual 
can result in death, serious bodily injury, and/or 
property loss or damage from hazards of fire, 
explosion, burn, asphyxiation, carbon monoxide 
poisoning, and/or electrical shock.

 

WARNING! Check the Dragon for proper air-to-fuel 
ratio at each location. Failure to adjust for altitude 
changes could cause injury, permanent damage to 
the unit and secondary damage when ducting into a 
structure. It may also void the Dri-Eaz warranty. 
Refer to “Adjusting for Altitude,” p. 5, for 
instructions.  

WARNING! Breathing Hazard. Fuel exhaust contains 
deadly carbon monoxide gas. Operate the Dragon 
only outdoors in open area. NEVER operate indoors 
or in enclosed spaces. 

  Do not stand closer than 8 ft. (2 m) from the outlet of 

the heater. Do not lean or sit on the heater. 

  Keep children and pets away. 

  Make sure there is sufficient air circulation around 

the unit during operation.  

  Only do repair and maintenance after the heater has 

cooled sufficiently and the heater is disconnected 
from the electric power.  

WARNING! Fire and Explosion Hazard 

  Burner produces sparks and flame and unit 

becomes hot during use. Hot surfaces can ignite fuel 
vapors. 

  Keep away from flammable vapors, such as those 

from gasoline, paint thinner or solvents.  

  Keep all flammable material away from the heater, 

including combustible dusts, such as coal dust or 
sawdust.  

  Keep unit at least 8 ft. (2 m) away from any com-

bustible material.  

  Diesel fuel is flammable and can be explosive. 

  Do not smoke while operating, servicing, or refueling 

the Dragon. 

 Before refueling, turn the unit off, allow it to cool, and 

then unplug.  

WARNING! Electric Shock Hazard 

  Unit must be grounded. Use only with 3-hole 

grounded outlet.  

  Never modify plug or use an adaptor. If an extension 

cord is needed, it must have a three-prong 
grounding plug and be rated for outdoor use. 

  Never operate the Dragon in pooled or standing 

water. If electrical components become wet, allow 
them to dry before using. 

 

 

WARNING

 

Summary of Contents for F507

Page 1: ...the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer to Adjusting for Altitude p 5 for instructions WARNING Breathing Hazard Fuel exhaust contains d...

Page 2: ...e Furnace is designed to operate on a 115V 60 Hz electrical connection The unit requires 10 amps Make sure that the electrical outlet is a three prong type grounded outlet When using with an extension...

Page 3: ...bstruction Avoid setting up unit in a location where the intake could be blocked or restricted Blocking the air intake will cause the unit to produce sooty exhaust potentially damaging the unit and th...

Page 4: ...Operating the Dragon Inspecting before operation WARNING Before starting the Dragon Check for any fuel leaks around the fuel tank or fuel lines Check for nearby hazards like combustible materials or f...

Page 5: ...or black there is not enough air in the mixture c If the smoke is white there is too much air and not enough fuel in the mixture or there is water in the fuel If the smoke color is either black or wh...

Page 6: ...once a year 1 Cleaning the fuel tank The fuel tank should be cleaned once a year To clean the tank follow these steps a Place an appropriate container beneath the fuel drain plug to catch any fuel b R...

Page 7: ...z 5 3 amps Fuel consumption 1 2 gal hr 4 5 L hr Fuel type Diesel fuel oil 2 Kerosene Fuel tank capacity on board 13 5 gal 51 1 L Rated heat output 130 000 BTU hr Process air output 900 CFM 1530 CMH Te...

Page 8: ...and supplies required Wrenches Wheel base axle and wheel installation Attach the wheel base assembly to both sides of the tank using the fasteners provided Install both wheels Place a washer on either...

Page 9: ...arranty 07 00424 9 Dri Eaz Products Inc Install rear stand First attach top of stand to the back edge of the tank using the fasteners provided Secure the front of the stand over the fuel drain plug wi...

Page 10: ...2012 10 Warranty 07 00424 10 Dri Eaz Products Inc Exhaust flue installation Slide flue down over exhaust flange as shown Ensure all fasteners are properly tightened and secure The Dragon is now ready...

Page 11: ...the existing fuel tank fitting from the tank Slide fitting off of fuel pickup tube and discard fitting 4 Using a tube cutter cut off metal pickup tube approximately in below the brass compression slee...

Page 12: ...gs Attach the two nipples to the hexagonal fuel tank fitting Attach a quick disconnect socket to the top nipple Attach a quick disconnect plug to the bottom nipple Attach an adapter to each of the fue...

Page 13: ...end of the return line Attach a quick disconnect socket to the adapter on the end of the fuel pick up line Attach a 90 fitting thru the filter bracket into the filter Rotate the fitting so that it po...

Page 14: ...t and plug ends together External fuel tank pickup setup The pickup fuel line assembly provided must be installed in an external fuel tank not supplied before use 1 Remove the pickup tank cover 2 Scre...

Page 15: ...07 01810A 2012 09 Warranty 07 00424 15 Dri Eaz Products Inc Fig 4 Electrical Schematic...

Page 16: ...de s rie ______________________________________________________ Distributor Distribuidor Distributeur ____________________________ Tel Tel T l ________________________ MAINTENANCE MANTENIMIENTO MAINTE...

Reviews: