Communication

Summary of Contents for RVP 2400

Page 1: ...System Center Lübeck Dräger RVP Communication ...

Page 2: ...2 Dräger RVP Communication Middelborg Olsson November 2011 Dräger RVP Communication Content Introduction Network Cable RVP 2400 RVP 3900 RVP 5000 Remote Communication ...

Page 3: ...1 There are 3 different variants of the RVP available Every variant has a different way of communication to its connected controller We will show the different types of communication for the RVP 2400 RVP 3900 and RVP 5000 Dräger RVP Communication Introduction ...

Page 4: ...s and this presentation refer to the EIA TIA 568B norm Dräger RVP Communication Network Cable Cable pair Pin EIA TIA 568A EIA TIA 568B IEC REA DIN 47 100 1 4 5 blue white blue white blue white white blue white brown 2 3 6 white orange white green red orange turquoise violet green yellow 3 1 2 white green white orange black grey white orange grey pink 4 7 8 white brown white brown yellow brown turq...

Page 5: ...2011 The RVP 2400 can be connected to up of 5 Regard 24xx RailGard XX Controller to visualize the data A configuration on the RVP 2400 is not necessary The addressing will be done via the Regard 24x0 configuration software Dräger RVP Communication RVP 2400 ...

Page 6: ...dressing starts from 1 up to 5 regarding the quantity of connected controller Baud rate Bits Parity and Stop bit must not be changed The default settings are 19200 8N1 The controller will be visible on the RVP 2400 with the same numbers addressed in the configuration software Dräger RVP Communication RVP 2400 ...

Page 7: ... incoming signals of the controller from RS232 to RS485 The RVP 2400 gets the data from the RS485 interface and make them visible on the screen 35 1 17 18 RS232 Power Reset Channel A B C D E F Concentration F1 F2 x10 Error Hu A1 A2 RailGard S6 A3 A4 A B C D E F 35 1 17 18 RS232 Power Reset Channel A B C D E F Concentration F1 F2 x10 Error Hu A1 A2 RailGard S6 A3 A4 A B C D E F Dräger RVP Communica...

Page 8: ... Connection of the converter colour of cable orange white RJ45 jack PIN 1 TxB Converter connector A colour of cable orange RJ45 jack PIN 2 TxA Converter connector B colour of cable green RJ45 jack PIN 6 Converter connector COM Dräger RVP Communication RVP 2400 ...

Page 9: ...9 Dräger RVP Communication Middelborg Olsson November 2011 The RVP 3900 is able to display data of up to 8 Regard 3900 3910 controller RS 485 max 1 2 Km Dräger RVP Communication RVP 3900 ...

Page 10: ...10 Dräger RVP Communication Middelborg Olsson November 2011 Example RVP 3900 connected to 2 Regard 3910 systems CAN Bus intern RS 485 Modbus System 1 System 2 Dräger RVP Communication RVP 3900 ...

Page 11: ... data on the RVP 3900 they first have to be transformed to the Modbus RTU protocol This will be done by the Regard 3900 Modbus Gateway SC00083 Each Regard 3900 that should be connected to a RVP 3900 needs this gateway 5x Regard 39X0 5x Gateway In every delivery there s a software and a Nullmodem cable for the configuration addressing Dräger RVP Communication RVP 3900 ...

Page 12: ...12 Dräger RVP Communication Middelborg Olsson November 2011 Regard 3900 Modbus Gateway Overview Connectors Dräger RVP Communication RVP 3900 ...

Page 13: ... to Regard 3900 display board Connector for Regard 3900 Configuration Cable Regard 3900 Modbus Gateway cable SC00084 Connector for Regard 3900 configuration cable 4208785 Connection Cable Gateway PIN 2 High PIN 4 Low Regard 3900 Modbus Gateway SC00083 Communication Regard 3900 Regard 3900 Modbus Gateway Dräger RVP Communication RVP 3900 ...

Page 14: ... internal system bus cable Regard 3910 Modbus Gateway cable SC00085 Connector for Regard 3900 configuration cable 4208785 Connection Cable Gateway PIN 2 Low PIN 3 High Regard 3900 Modbus Gateway SC00083 Regard 3900 3910 ribbon cable Communication Regard 3910 Regard 3900 Modbus Gateway Dräger RVP Communication RVP 3900 ...

Page 15: ...ication Middelborg Olsson November 2011 Communication Regard 3900 Modbus Gateway RVP 3900 orange white RJ45 jack PIN 1 TxB Gateway RS485 orange RJ45 jack PIN 2 TxA Gateway RS485 CAN RS485 Dräger RVP Communication RVP 3900 ...

Page 16: ...umper from Pos 2 to Pos 3 without power supply Connect to power supply yellow LED will blink fast Connect Nullmodem cable Start Configuration program choose Address file from the directory Download file to the gateway After finishing disconnect the gateway from the power supply and set back the Boot Jumper Reconnect the unit to the power supply Dräger RVP Communication RVP 3900 ...

Page 17: ... Modbus Gateway Card In the standard application the RVP 5000 is able to visualize up to 99 channel from only 1 Regard system As the Regard system only transfers status messages and values and not any data of the system configuration the RVP 5000 needs a configuration file Dräger RVP Communication RVP 5000 ...

Page 18: ... via the REGARD Configuration software Login into Service Level load create a system configuration click button Export to CSV choose file name max 8 digits and save csv file Copy file onto the CF card of the RVP 5000 via card reader or USB connection to unit Dräger RVP Communication RVP 5000 ...

Page 19: ...on the RVP 5000 Login as administrator in the menu Settings Touch the button Import Configuration Touch the field below File Name and type in the file name with extension csv Touch the button Import Conf Wait 300 Seconds until the file is saved in the system Dräger RVP Communication RVP 5000 ...

Page 20: ...52 1 GATE Set Modbus slave number 1 1 52 2 BAD2 Function 02 disable exceptions YES NO 52 3 BAD4 Function 04 disable exceptions YES NO 52 4 BAUD Set baudrate 4800 9600 52 5 PRTY Set pirarity NONE NONE 52 6 CKSM REGARD communication check sum CRC CRC 52 7 FRMT Set gas concentration format SIGN SIGN 60 1 DISP Switch display on off OFF ON SW2 Set switch on REGARD Modbus card to RS422 485 52 1 For more...

Page 21: ...21 Dräger RVP Communication Middelborg Olsson November 2011 REGARD Modbus Interface Card Connection RS485 Jack on RS485 Port of RVP 5000 Dräger RVP Communication RVP 5000 ...

Page 22: ...The 2nd RVP 5000 then will be the Master getting data from the Slave that is connected to the Regard system For newer RVP s since July 2011 there s no special firmware upgrade necessary The Master Slave connection will be done via RS485 There s an optional RS485 module in the Slave unit required The cable for this connection is a standard LAN cable CAT5 or higher The data can be shown individual o...

Page 23: ... R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD R D räger REGARD R Connection Schematic Slave Master RS485 RS485 RVP 5000 RVP 5000 Regard System Dräger RVP Communication Remote Communication ...

Page 24: ...24 Dräger RVP Communication Middelborg Olsson November 2011 RVP 2400 3900 5000 Internal RS485 output card Dräger RVP Communication Communication Solutions ...

Page 25: ...25 Dräger RVP Communication Middelborg Olsson November 2011 RVP 2400 Internal Profibus DP output card Dräger RVP Communication Communication Solutions ...

Page 26: ...26 Dräger RVP Communication Middelborg Olsson November 2011 Regard 39X0 Regard 3900 Profibus DP Gateway for the communication to a PLC Dräger RVP Communication Communication Solutions ...

Page 27: ...27 Dräger RVP Communication Middelborg Olsson November 2011 Regard 3900 RVP 3900 Regard 3900 Modbus TCPIP Gateway to connect to a RVP or PLC via network Dräger RVP Communication Communication Solutions ...

Page 28: ... D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R S ach Nr 4205700 D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD Shift R D räger REGARD Shift R D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R D räger REGARD R Island 1 64 detectors System 1 Island 2 10 detectors System 2 ADAM 4572 RS485 to ...

Page 29: ...29 Dräger RVP Communication Middelborg Olsson November 2011 Thank You ...