Portable Mesh Nebulizer 

■ Intended Use:   
Legally certified medical experts, such as doctor, nurse and therapist, or healthcare personnel or 
patient under the guidance of qualified medical experts .

 

 

The user should also be capable of understanding general 
operation of Mesh Nebulizer and the content of instruction 
manual 
■Intended User: 
Adult and pediatric patients suffer from asthma, Chronic 
Obstructive Pulmonary Disease (COPD) such as 
emphysema and chronic bronchitis, or other respiratory 
diseases that are characterized by obstruction to air flow 
■ Environment 
This product is intended for use in a medical facility, such 
as Hospital, clinic and doctor’s office, in a room of general 
household, and in open-air environment with a roof. 
■ Durable period 
Durable periods are as follows, provided the product is 
used to nebulize saline 3 times a day for 10 minutes each 
time at room temperature (23°C).Durable period may vary 
depending on usage environment. 
■CAUTION: Federal law restricts this device to sale by or 
on the order of a physician.   
 
 
 
 
 
 
 

Summary of Contents for Micro Mesh Nebulizer

Page 1: ...sease COPD such as emphysema and chronic bronchitis or other respiratory diseases that are characterized by obstruction to air flow Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s office in a room of general household and in open air environment with a roof Durable period Durable periods are as follows provided the product is used to nebulize...

Page 2: ...w to connect to the power supply 6 How to fill the medication 9 How to operate the nebulizer 10 Cleaning How to clean after using 14 How to replace the medication chamber 17 How to Carry How to carry the nebulizer 18 Troubleshooting Troubleshooting 20 Specifications Specifications 23 Technical data 24 Accessories Optional part 26 Note 27 Appendix A EMC information 29 IMPORTANT CAUTION As with any ...

Page 3: ...ug or unplug the AC adapter with wet hands Caution If device does not shut off automatically when medication is depleted and gives off a high frequency sound press the START STOP button to turn the power off immediately to avoid the mesh breaking Please go to page 18 for troubleshooting Please clean the nebulizer parts carefully after each use Otherwise it may not function If you fill water in the...

Page 4: ...the medication does not contact the mesh it can nebulize properly for about 15 seconds Time varies depending on specific medication types The package contains the following components 1 Main unit 2 Main unit cover 3 Medication chamber 4 Alkaline batteries AA 1 5Vx2 Optional 5 Mouthpiece 6 Carrying pouch 7 USB cable optional USB cable is Optional 8 Inhalation mask Small multi use Large multi use Pr...

Page 5: ...5 Components Names and Functions ...

Page 6: ...ion chamber clean otherwise the nebulizer may not function properly 1 Attach the medication chamber to the main unit Attach the medication chamber while it gives off a sound Click 2 Attach the mouthpiece Please securely attach the Mouthpiece to main unit 3 Attach the inhalation mask Inhalation mask for children is S size Inhalation mask for adults is L size Attach the Mask How to assemble Mesh neb...

Page 7: ...life and replacement Up to 3 0 hour if used continuously Use 2 AA LR6 alkaline batteries 6 days if used 3 times daily 10 minutes per time If the low power indicator with orange color is lit to flash 2Hz it means battery is low But Nebulizer still can be used around 30 minutes continuously If the low power indicator with orange color lit constantly orange color it means that extremely low power cau...

Page 8: ...upply inlet 2 Plug the AC adapter into an electric outlet General Recommendations Attention Do not mix different types of batteries Battery life may be different depending on type of the batteries used Please unplug the AC adapter after use Do not leave it connected to the power supply for a long time ...

Page 9: ...he chamber is detached from the main unit Please remove the main unit cover mask adapter and mouthpiece and inhalation mask first 1 Remove the medication chamber from the main unit Press the PUSH button on the rear side of the main unit and push the medication chamber towards the front side of the main unit Attention 2 Fill the medication Fill the medication as shown in the figure Recommended fill...

Page 10: ...curely attach the Mouthpiece to main unit 5 Attach the inhalation mask Inhalation mask for children is S size Inhalation mask for adults is L size Make sure the medication chamber is attached correctly or the bad connection may result in malfunction To ensure correct functioning of Nebulizer keep the electrodes of the main unit and the medication chamber clean ...

Page 11: ...nside the medication chamber and the power is turned on The nebulizer s power indicator green will be turned on around 0 5 second then the power indicator will be changed to orange color immediately After 8 seconds medication chamber light and shut off power automatically In the operation while medication was depleted the power indicator will be changed to orange color immediately and turned off m...

Page 12: ...g During the treatment you may adjust the nebulizer to any angle However make sure the medication stays in contact with the mesh otherwise the nebulizer will shut off automatically after approximately 15seconds When the medication is about to be depleted it is recommended that you tilt the nebulizer the buttons side slightly toward you This allows the remaining medication to contact the mesh to ne...

Page 13: ...ically after the medication is depleted If you wish to halt the treatment press the START STOP button to turn the power off The power indicator light will go out If the AC adapter is being used please unplug from the wall outlet after turning off the power ...

Page 14: ...ineral water depleted 2 Dismantle the nebulizer Remove the medication chamber and inhalation mask or mouthpiece from the nebulizer Attention 3 Clean the parts with sufficient amounts of distilled water Clean the medication chamber mouthpiece inhalation mask with distilled water How to clean after using The inhalation mask in first use must be cleaned with distilled water and dried These parts can ...

Page 15: ...nduction and hence a normal nebulization 4 Dry the cleaned parts thoroughly After the parts are cleaned dry with new gauze and air dry thoroughly Attention 5 Wipe off the main unit with new gauze Dab a piece of gauze with water and lightly wipe off the stains from the main unit Then use new gauze to dry Please clean the electrodes on the main unit and medication chamber This ensures a normal elect...

Page 16: ...er or damage may occur Dry completely In the case of infectious illnesses the device must be disinfected every day or all attachments must be sterilized You can also use alcohol or other common alcohol based disinfectant sprays Make sure that no disinfectant residues are left behind on the attachments to ensure safe inhalation when next used ...

Page 17: ...y However the nebulization performance may start deteriorating in less than 6 months depending on the way you use it or the use of certain types of medication If the nebulizer can not nebulize or the nebulization rate decreases significantly after clean you must replace the medication chamber with a new one If you want to purchase a medication chamber please contact suppliers How to replace the me...

Page 18: ... cause the nebulizer to not function properly Please keep the electrodes of the main unit and medication chamber clean otherwise the nebulizer may not function properly Please clean the medication chamber before using 1 Remove the medication chamber from the nebulizer Press the PUSH button on the rear side of the main unit and push the medication chamber toward the front side of the main unit 2 Re...

Page 19: ...bulizer from possible damage during carrying 3 USB cable optional For easy carrying please bind the USB cable and its electric wire together with a ribbon band as shown in the figure 4 Place the main unit and associated parts into the carrying pouch for carrying Attention How to carry the nebulizer Please do not carry a nebulizer that still contains medication or water The medication may leak out ...

Page 20: ...attach the medication chamber correctly and restart the power See page 6 No medication in medication chamber Put in the medication in the medication chamber See page 9 10 No contact between medication and mesh Adjust the nebulizer s angle so the medication can come in contact See page 11 Electrodes on nebulizer and medication chamber are stained Remove the stains and restart the power See page 14 ...

Page 21: ...r See page 13 16 Nebulizer shuts off during usage Medication chamber is loosened and not completely attached Re attach the medication chamber correctly and restart the power See page 6 Connection of USB cable to nebulizer is loosened Re connect in the correct manner and restart the power See page 8 Medication has run out Put in the medication in the medication chamber See page 9 10 No contact betw...

Page 22: ...logged with medication or water Clear the electrodes of clogged medication or water and restart the power See page 14 Electrodes on nebulizer and medication chamber are stained Remove the stains and restart the power See page 14 Medication chamber is broken Purchase and replace with a new medication chamber See page 16 Overflow of medication from medication chamber Rupture of medication chamber or...

Page 23: ...y Use 2 AA LR6 alkaline batteries Durable period Durable periods are as follows provided the product is used to nebulize saline 3 times a day for 15 minutes each time at room temperature 23 C Durable period may vary depending on usage environment Main unit 3 years Medication Chamber 6 months Allows operation in all directions upside down or tilted for up to 15 seconds Detection if no medication or...

Page 24: ...as suspensions or high viscosity See drugs supplier s data sheet for further details MMAD Mass Median Aerodynamic Diameter Mass Median Aerodynamic Diameter MMAD 3 6μm Mass Median Aerodynamic Diameter The Bottle Capacity MAX 8ml Noise 50db Range of 1m Particle size distribution compliant with EN 13544 1 Technical data ...

Page 25: ...hown below If you wish to purchase any of them please contact supplier Inhalation mask S For Children Inhalation mask L For Adult Medication chamber Mouthpiece Main unit cover Carrying pouch USB cable optional Accessories Optional parts ...

Page 26: ...art IP22 Not suitable for use in presence of flammable anesthetic mixture with oxygen or nitrous oxide Continuous operation To avoid nebulizer s abnormal operation caused by electromagnetic interference between electrical and electronic equipment do not use the device near a cell phone or microwave oven Wellkang Tech Consulting Suite B 29 Harley Street LONDON W1G9QR United Kingdom Reading Instruct...

Page 27: ... communications However there is no guarantee that inference will not occur in a particular installation If this equipment does cause harmful inference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inference by one or more of the following measures Reorient or relocate the receiving antenna Increase the sep...

Page 28: ...gnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6kV contact 6kV contact Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity sho...

Page 29: ... UT for 5 sec power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the AC mains voltage prior to application of the test level ...

Page 30: ...ment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio ...

Page 31: ...2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance f...