background image

1

CONTENTS

Technical Description

2

Specifications

9

3511: Cardioid Stereo Kit, P48.

12

Care of Microphones

14

Service and Repair

14

Warranty

15

CE-Marking

15

Environmental Policy

16

USER’S MANUAL

Cardioid Microphones

Wide Cardioid Microphones

Included in kit solutions:

Type

40 1 1-TL

Type

40 12

Type

3 5 1 1

Type

4015-TL

Type

40 16

Summary of Contents for 351 1

Page 1: ...dioid Stereo Kit P48 12 Care of Microphones 14 Service and Repair 14 Warranty 15 CE Marking 15 Environmental Policy 16 USER S MANUAL Cardioid Microphones Wide Cardioid Microphones Included in kit solutions Type 4011 TL Type 4012 Type 3511 Type 4015 TL Type 4016 ...

Page 2: ...on has also been paid to the microphone s natural sounding off axis performance during the design process see Fig 3 4 The diaphragm is protected from dust by an acoustically trans parent net behind the front protection grid and inside the back port of the cartridge For optimum stability the microphone cartridge has undergone a special pre aging process which stabilizes all tensions in the material...

Page 3: ...idual frequency response The Passive Connection Converter The PCC4000 Passive Connection Converter is an optional accessory that makes it possible to run high voltage microphones on standard 48 V phantom power with reduced microphone specifications The maximum reduction of the microphone SPL handling capability will be 13 dB and it is possible to drive up to 100 m of cable with the PCC4000 with th...

Page 4: ...haracteristics of 4011 TL and 4012 normalised Shifts between emphasized circles indicate 10 dB steps Fig 2 Directional characteristics of 4015 TL and 4016 normalised Shifts between emphasized circles indicate 5 dB steps 0 0 ...

Page 5: ...5 Fig 3 On and off axis responses of 4011 TL and 4012 measured at 30 cm Fig 4 On and off axis responses of 4015 TL and 4016 measured at 60 cm ...

Page 6: ... the 4012 and 4016 Fig 5 External view of the output socket of the 4011 TL and 4015 TL Fig 6 The switch on the XLR connector of 4011 TL and 4015 TL is used to select between 0 dB and 20 dB attenuation Switch pressed in results in 20 dB attenuation ...

Page 7: ...7 Fig 8 The proximity effect exhibited by the 4011 TL and the 4012 Fig 9 The proximity effect exhibited by the 4015 TL and the 4016 ...

Page 8: ...e response of Types 4011 TL 4012 4015 TL and 4016 plotted using a linear frequency axis for evaluation of the phase response Fig 11 Typical third octave inherent noise spectrum of Types 4011 TL 4012 4015 TL and 4016 ...

Page 9: ...icrophones 15 Directional characteristics 4011 TL and 4012 First order cardioid 4015 TL and 4016 Wide cardioid Sensitivity 4011 TL and 4015 TL Nominally 10 mV Pa 40 dB re 1 V Pa 4012 and 4016 Nominally 9 mV Pa 41 dB re 1 V Pa Equivalent noise level A weighted Typ 19 dB A re 20 µPa max 20 dB A Equivalent noise level ITU R BS 468 4 Typ 25 dB Max SPL 4011 TL and 4015 TL 158 dB SPL peak before clippin...

Page 10: ... 5 4012 and 4016 Positively increasing sound pressure produces positive going voltage at pin 4 Pin 1 Ground Pin 2 Not used Pin 3 130 V DC preamplifier supply Pin 4 Signal See Fig 7 Difference frequency distortion DF2 DF3 Df 70 Hz 0 5 at 110 dB SPL peak Influence of vibration 71 dB equivalent SPL for 1 m s2 in direction of greatest sensitivity Influence of magnetic field 45 dB equivalent SPL for 80...

Page 11: ...ium Soft Microphone Holders Suspension Mounts UA0639 Microphone Clip Stereo Accessories DUA0019 Spacer for Stereo Boom 19 mm UA0836 Stereo Boom with Holders UA0837 Stereo Boom excluding Holders Floor Table Stands MB4000 Magnet Base TB4000 Table Base Connection Adapters HTP4000 Converter 130 V to P48 PCC4000 Passive Connection Converter P48 to 130 V Cables DAO0130 130 V Microphone Cable 5 m Type HM...

Page 12: ...recordings of jazz or pop with a placement closer to the ham mers or as overheads The kit includes 2 Shock Mounts a precision crafted Stereo Boom for secure mounting of microphone pairs for A B stereo recordings and a spacer to allow XY or ORTF stereo set ups on the boom 3511 KIT INCLUDES 2 x 4011 TL Cardioid Microphones P48 matched 2 x UA0897 Shock Mount UA0836 Stereo Boom with Holders DUA 0019 S...

Page 13: ...13 3511 Popfilter with 4015 TL ...

Page 14: ...crophone should be disconnected and kept in the case supplied SERVICE REPAIR Products from DPA Microphones are extremely stable and there should not be any significant change in the specifications with time and use If however you are not totally satisfied with the charac teristics exhibited by these products contact your nearest DPA Microphones representative for further details of service and the...

Page 15: ...uirements at present directive 9002 95 EC at the time a new product is introduced to the market These requirements are valid for DPA as well as for our suppliers With respect to waste disposal we comply in full with the WEEE directive 9002 96 EC and are prepared to comply to any amend ments and succeeding requirements in connection hereto Thus starting from 1 January 2006 all DPA products that req...

Page 16: ... registration CE MARKING The CE mark guarantees all products conform with relevant standards approved by the European Community The products described in this User s Manual comply with current relevant standards when used with cables from DPA Microphones EMC Directive 89 336 EEC amended by 92 31 EEC and 93 68 EEC Low Voltage Directive 73 23 EEC amended by 93 68 EEC 2005 DPA Microphones A S Product...