background image

JA6 & JAOP6

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DANGER

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS

TABLE OF CONTENTS

SECTION « A » DESCRIPTION

 

    

 PAGE

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A1

Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A2

Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Installation warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A3

Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A5

Operation / instruction for oven and proofer. . . . . . . . . . . . . . . . . . . . . . . . A6
Operation for proofer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A8

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A9

Oven maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A11

For more information, please contact our office: . . . . . . . . . . . . . . . . . . . . A12
Optional auto steam injection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A13

Optional watlow control operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A14

SECTION « B » DIMENSIONS

  JAOP6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B1

  JA6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B5

SECTION « E » COMPONENT PARTS

  Component parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E1

SECTION « F » CONTROL PANELS

  Control panel 120V/208V/1PH & 120V/240V/1PH . . . . . . . . . . . . . . .

F1

  Control panel 120V/208V/3PH & 120V/240V/3PH . . . . . . . . . . . . . . .

F3

  Control panel 220V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

F5

  Control panel 220V/380V/3PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . .

F7

Summary of Contents for JA6

Page 1: ...eration instruction for oven and proofer A6 Operation for proofer A8 Troubleshooting A9 Oven maintenance and cleaning A11 For more information please contact our office A12 Optional auto steam injection A13 Optional watlow control operation A14 SECTION B DIMENSIONS JAOP6 B1 JA6 B5 SECTION E COMPONENT PARTS Component parts E1 SECTION F CONTROL PANELS Control panel 120V 208V 1PH 120V 240V 1PH F1 Con...

Page 2: ...H 50 Hz G5 JAOP6 220V 1PH 60 Hz G6 JAOP6 220V 380V 3PH 50 Hz G7 JA6 120V 208V 1PH 60 Hz 120V 240V 1PH 60 Hz G8 JA6 120V 208V 3PH 60 Hz 120V 240V 3PH 60 Hz G9 JA6 220V 1PH 50 Hz G10 JAOP6 120V 208V 1PH 120V 240V 1PH AUTO STEAM G11 JAOP6 120V 208V 3PH 120V 240V 3PH AUTO STEAM G12 JAOP6 120V 208V 1PH 120V 240V 1PH WATLOW G13 JAOP6 120V 208V 3PH 120V 240V 3PH WATLOW G14 Warranty FAM6 EA DOC Rev 26 05 ...

Page 3: ...e oven specifies the model number serial number voltage and amperage Drawings electrical diagram and replacement parts numbers are included in this manual The electrical diagram is affixed in the control panel at the back of the oven ATTENTION DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organisations The customer is respon...

Page 4: ... and carefully crated before shipment The freight company assumes full responsibility concerning the delivery in good condition of the equipment in accepting to transport it IMPORTANT RECEPTION OF THE MERCHANDISE Take care to verify that the received equipment is not damaged before signing the delivery receipt If a damage or a lost part is noticed write it clearly on the receipt If it is noticed a...

Page 5: ...INTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT Installation and service must be done by specialised technicians Contact a certified electrician and plumber for set up The oven must be connected to the utility and electrically grounded in conformity to the effective local regulations If these are not established the oven must be connected according to the Canadian E...

Page 6: ...ng must exist to permit adequate venting C Floor 4 inches minimum D Sides of the oven do not install other than easily removable equipment for service and maintenance not closer than 1 inch E It is recommended to have a certain length of water pipe electric cable between oven and wall to help gain access for service ...

Page 7: ... that the supply cable does not come in contact with the oven top which becomes hot 2 To the plumber This equipment is to be installed to comply with the applicable federal state or local plumbing codes Connect the steam system 1 4 NPT to the cold water distribution network We highly recommend to use a water softener to eliminate minerals in the water We suggest you to use CUNO CFS6135 Doyon part ...

Page 8: ...ctivates the buzzer 6 Wait until the product is ready Do not open the doors until the product is done VERY IMPORTANT This oven has an overheat warning alarm to protect the electrical components against overheating If the red pilot light OVERHEAT WARNING is lit and you hear a buzzer see troubleshooting THERMOSTAT INSTRUCTIONS To obtain a very good thermal stability we use a digital temperature cont...

Page 9: ...green display is the setting time and the red display is the countdown time Ex 25 minutes set 2500 on green display After setting Push the START STOP button then when the time expires the buzzer will ring Push the START STOP button again to stop the buzzer If you want to restart the time in the middle of the countdown press on the yellow RST button on the timer P S The timer is simply a reminder f...

Page 10: ...them inside until they are ready to bake 6 IMPORTANT When proofing cycle is completed turn the humidity switch to OFF and let the motor blower and air heat element run for 10 15 minutes to let dry the proofer Then turn the main switch off and leave the door ajar to prevent moulding When the proofer is not in operation open the doors to let out the humidity and to prevent mould P S The doors should...

Page 11: ...n baking Make sure that the grills do not obstruct the air flow Do not use foil on the grills Verify the temperature of the oven by using an oven thermometer and make sure that it is even with the thermostat setting If the oven is baking too much on the sides it is possible that the fan is not cycling properly Verify if the motor turns 2 5 minutes in a direction stops 30 seconds and starts for 2 5...

Page 12: ...stays on when the water pan is full You have no more water in the principal water pan Check if the water line is not in air lock condition Disconnect the water line at the inlet of the green solenoid valve and clean the strainer filter Also clean the principal water pan and the float switch If there is no light in the proofer 1 Verify every breaker in front of the proofer 2 Verify the main proofer...

Page 13: ...Off We recommend and sell Dirt Buster III Action foam cleaner CHEMCO Part number NEB201 After cleaning the inside of the oven apply a silicone base oven protector It avoids food from sticking to the metal We recommend and sell 316 Silicone base protector and lubricant for oven Dow Corning Part number EXS400 Clean the oven windows with products like Brasso or equivalents They are copper cleaners bu...

Page 14: ... PLEASE CONTACT OUR OFFICE DOYON EQUIPMENT INC 1255 rue Principale Linière Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet http www doyon qc ca E Mail doyon doyon qc ca ...

Page 15: ...er white light will light up during the steam injection Push the RED button to stop the automatic steam injection and then the GREEN button will turn off Timer adjustments EXAMPLE For 5 seconds of steam injection every 10 minutes Set the interval multiplicator screw OFF at MIN and the GREEN needle at 10 Set the injection multiplicator screw ON at SEC and the RED needle at 5 EXAMPLE For 2 seconds o...

Page 16: ...5 SEC COOKING TIME 22 MINUTES WITH BUZZER MENU 3 350 F STEAM 15 SEC COOKING TIME 25 MINUTES WITH BUZZER MENU 4 325 F NO STEAM COOKING TIME 25 MINUTES WITH BUZZER 325 F Muffins 350 F Croissants Sweet Doughs Small rolls 375o F Baguette bread round loaf 10 oz bread and more 375o F If the oven is filled to its capacity OPENING AND CLOSING OF THE DOORS To open the doors Open one of the doors up to 2 an...

Page 17: ...ary press 12 and CLOCK LOC appears Use the arrows to get 0 and press CLOCK again To put back on read only mode you have to have 1 before pressing on CLOCK EXAMPLE 1 preheat program For menu 1 we will program it so that we have a preheat time of 20 minutes at 400 F followed by a 15 seconds buzzer Step 1 Press both arrows simultaneously for 5 seconds Both lights light up to show that the programming...

Page 18: ...1 Step 3 Suggested values SP3 appears Use the arrows to adjust to the desired temperature 400 F Press on the number of the menu to confirm ex 1 t3 appears Use the arrows to select the desired timing 00 01 Press on the number of the menu to confirm ex 1 E3 appears Use the arrows to select the desired code 0000 for no event Press on the number of the menu to confirm ex 1 To get out of the programmin...

Page 19: ...5 F Press on the number of the menu to confirm ex 2 t1 appears Use the arrows to select the desired timing 00 20 Press on the number of the menu to confirm ex 2 E1 appears Use the arrows to select the appropriate code 0001 for the steam Press on the number of the menu to confirm ex 2 Step 2 Suggested values SP2 appears Use the arrows to adjust to the desired temperature 375 F Press on the number o...

Page 20: ...heat because there was a temperature included in step 3 If the temperature at that step would have been of 0 F the oven would have stopped at the end of the program In this example the inside buzzer will work 15 seconds while the outside buzzer will start and will not stop until another program is selected If you want to end a program already running press the button corresponding to that menu and...

Page 21: ...SECTION B DIMENSIONS ...

Page 22: ...B1 BAKING TIMER THERMOSTAT 36 1 2 72 3 4 JAOP6 JAOP6 DEPTH WIDTH HEIGHT INTERIOR DIMENSIONS PROOFER DEPTH WIDTH HEIGHT INTERIOR DIMENSIONS OVEN 26 1 4 25 1 2 30 1 2 36 1 2 26 1 2 26 1 2 ...

Page 23: ...B2 38 1 2 72 3 4 5 AMPS JAOP6W JAOP6 WATLOW 26 1 2 26 1 2 36 1 2 30 1 2 25 1 2 26 1 4 OVEN INTERIOR DIMENSIONS HEIGHT WIDTH DEPTH PROOFER INTERIOR DIMENSIONS HEIGHT WIDTH DEPTH ...

Page 24: ...B3 48 1 4 JAOP6 JAOP6 ...

Page 25: ...B4 ENTRÉE D EAU Ø1 4 WATER INLET Ø1 4 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET JAOP6 JAOP6 ...

Page 26: ...B5 BAKING TIMER THERMOSTAT 36 1 2 34 3 4 38 35 7 8 JA6 JA6 30 1 2 25 1 2 26 1 4 OVEN INTERIOR DIMENSIONS HEIGHT WIDTH DEPTH ...

Page 27: ...B6 48 1 4 37 7 8 JA6 JA6 ...

Page 28: ...B7 ENTRÉE D EAU Ø1 4 WATER INLET Ø1 4 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET JA6 JA6 ...

Page 29: ...SECTION E COMPONENT PARTS ...

Page 30: ...E1 BAKING TIMER THERMOSTAT 1 2 4 6 7 8 12 14 15 16 17 JAOP6 JAOP6 ...

Page 31: ...Y CONT 1 AND ELI240 INFINITY SWITCH KNOB 1 AND ELI230 INFINITY SWITCH 240V HUMIDITY CONT 1 OR ELI240 INFINITY SWITCH KNOB 1 12 QUP460 DOOR HANDLE BLACK 4 OR QUP465 DOOR HANDLE STAINLESS TUBING 4 13 ELB097 20A BREAKER 2 AND ELB098 2A BREAKER WITHOUT 120 V 1 14 QUA200 DOOR MAGNET 8 15 PAR800 SWIVEL CASTER 2 AND PAR850 SWIVEL CASTER WITH BRAKE 2 16 P1428EG LEFT DOOR FOR PROOFER 14 1 4 X28 3 4 1 AND P...

Page 32: ...E3 1 2 5 6 9 11 12 13 14 5 AMPS JAOP6W JAOP6 WATLOW ...

Page 33: ...NT 1 AND ELI240 INFINITY SWITCH KNOB 1 OR ELI230 INFINITY SWITCH 240V HUMIDITY CONT 50Hz 1 AND ELI240 INFINITY SWITCH KNOB 1 9 QUP460 DOOR HANDLE BLACK 4 OR QUP465 DOOR HANDLE STAINLESS TUBING 4 10 ELB097 20A BREAKER 2 11 QUA200 DOOR MAGNET 8 12 PAR800 SWIVEL CASTER 2 AND PAR850 SWIVEL CASTER WITH BRAKE 2 13 P1428EG LEFT DOOR FOR PROOFER 14 1 4 X28 3 4 1 AND P1428ED RIGHT DOOR FOR PROOFER 14 1 4 X...

Page 34: ...E5 6 5 4 3 2 1 11 10 9 7 8 OVEN X1 X3 X4 X2 H4 H2 H1 H3 H4 X1 PROOF H2 X3 H3 H1 X2 X4 12 13 JAOP6 JAOP6 ...

Page 35: ... BUZZER 120V 2 6 ELT503 HIGH LIMIT SWITCH 140 F 1 AND ELT507 HIGH LIMIT THERMODISC SWITCH 110 F 1 7 ELD050 INCANDESCENT LIGHT SOCKET 10 8 ELT506 HIGH LIMIT TEMPERATURE 1 9 ELC615 RELAY 10A 2P COIL 110V 1 AND ELC617 BASE 1 10 ELS880 SOLENOID VALVE 110 120V 50 60Hz 1 11 QUF350 ELECTRIC FLOAT 1 12 ELT712 TRANSFORMER 240 120 50VA 50 60 Hz 1 AND ELT715 TRANSFORMER 240 120 100VA 50 60 Hz 1 13 ELC630 CON...

Page 36: ...E7 6 5 4 3 2 1 11 10 9 7 8 OVEN X1 X3 X4 X2 H4 H2 H1 H3 H4 X1 PROOF H2 X3 H3 H1 X2 X4 12 13 14 15 16 JAOP6W JAOP6 WATLOW ...

Page 37: ...HERMODISC SWITCH 110 F 1 7 ELD050 INCANDESCENT LIGHT SOCKET 10 8 ELT506 HIGH LIMIT TEMPERATURE 1 9 ELC615 RELAY 10A 2P COIL 110V 1 AND ELC617 BASE 1 10 ELS880 SOLENOID VALVE 110 120V 50 60Hz 1 11 QUF350 ELECTRIC FLOAT 1 12 ELT712 TRANSFORMER 240 120 50VA 50 60 Hz 1 AND ELT715 TRANSFORMER 240 120 100VA 50 60 Hz 1 13 ELC800 SOLID STATE RELAY S S R 3 14 ELF960 LITTLE FUSE HOLDER 30A 300V 1 AND ELF855...

Page 38: ...E9 4 5 1 2 3 JAOP6 JAOP6 ...

Page 39: ...208V 3PH SINGLE 1 OR PANEL 220V 1PH 50Hz 1 OR PANEL 220 380V 3PH 50Hz 1 2 ELM800M MOTOR 75HP 1PH 115 208 230V 60Hz 50Hz A O SMITH 1 OR ELM820M MOTOR 3 4HP 3PH 208 230 460V 60Hz 50Hz A O SMITH 1 3 PLF100 WATER FILTER 1 4 ELS880 SOLENOID VALVE 110 120V 50 60Hz 1 5 ELV590 NEEDLE VALVE 2 Model JAOP 6 E View BACK ...

Page 40: ...SECTION F CONTROL PANELS ...

Page 41: ...F1 1 2 3 4 11 5 6 12 7 13 8 9 10 1 SEC 0 1 2 3 4 5 6 7 8 9 10 11 12 H3DE M1 PAN240S 240 VOLTS 1 PHASE SIMPLE DELAY ...

Page 42: ...NIQUE 2 5 TO 4 AMPS 1 6 ELO098 OVERLOAD 2 5 4 Amps 1 AND ELO125 OVERLOAD BASE RELAY 1 7 ELM715 PRESET TIMER 25SEC OFF 150SEC ON 1 8 ELB073 TERMINAL BLOCK 30A 9 9 ELF970 FUSE HOLDER 30A 250V 2P 1 10 ELF820 FUSE 8A 250V 2 11 ELM614 OMRON STEAM TIMER H3DE 1 12 ELM720 OMRON CONTROL TIMER 11 PIN H3CR DELAY OPTION 1 AND ELM729 11 PIN BASE DELAY OPTION 1 13 ELC630 CONTROL RELAY 12A COIL 120V AUTO STEAM O...

Page 43: ...F3 1 SEC 0 1 2 3 4 5 6 7 8 9 10 11 12 H3DE M1 1 2 3 11 4 5 6 7 12 8 13 9 10 PAN208S 208 VOLTS 3 PHASES SIMPLE DELAY ...

Page 44: ...ACTOR 2HP 1 ELC505B CONTACTOR COIL ONLY AND ELC960 TELEMECANIC AUXILIARY CONTACT BLOCK WITHOUT 120 V 2 6 ELB073 TERMINAL BLOCK 30A 6 7 ELL050 GROUND LUG 2 8 ELM715 PRESET TIMER 25SEC OFF 150SEC ON 1 9 ELF995 FUSEHOLDER 30A 250V 3P 1 10 ELF820 FUSE 8A 250V 3 11 ELM614 OMRON STEAM TIMER H3DE 1 12 ELM720 OMRON CONTROL TIMER 11 PIN H3CR DELAY OPTION 1 AND ELM729 11 PIN BASE DELAY OPTION 1 13 ELC630 CO...

Page 45: ...F5 4 11 5 6 12 7 13 8 9 10 1 2 3 1 SEC 0 1 2 3 4 5 6 7 8 9 10 11 12 H3DE M1 PAN220S 220 VOLTS 1 PHASE SIMPLE DELAY ...

Page 46: ... AUXILIARY CONTACT BLOCK 2 6 ELO101 OVERLOAD 4 6 AMPS 1 AND ELO125 OVERLOAD BASE RELAY 1 7 ELM715 PRESET TIMER 25SEC OFF 150SEC ON 1 8 ELB073 TERMINAL BLOCK 30A 9 9 ELF975 FUSE HOLDER 30A 250V 1P 1 10 ELF820 FUSE 8A 250V 2 11 ELM614 OMRON STEAM TIMER H3DE 1 12 ELM720 OMRON CONTROL TIMER 11 PIN H3CR DELAY OPTION 1 AND ELM729 11 PIN BASE DELAY OPTION 1 13 ELC630 CONTROL RELAY 12A COIL 120V AUTO STEA...

Page 47: ...F7 1 2 3 4 11 5 6 12 7 13 8 9 10 1 SEC 0 1 2 3 4 5 6 7 8 9 10 11 12 H3DE M1 PAN380S 220 380 VOLTS 3 PHASES SIMPLE DELAY ...

Page 48: ...C505B CONTACTOR COIL ONLY AND ELC960 TELEMECANIC AUXILIARY CONTACT BLOCK 2 7 ELM715 PRESET TIMER 25SEC OFF 150SEC ON 1 8 ELB073 TERMINAL BLOCK 30A 6 9 ELF995 FUSEHOLDER 30A 250V 3P 1 10 ELF820 FUSE 8A 250V 3 11 ELM614 OMRON STEAM TIMER H3DE 1 12 ELM720 OMRON CONTROL TIMER 11 PIN H3CR DELAY OPTION 1 AND ELM729 11 PIN BASE DELAY OPTION 1 13 ELC630 CONTROL RELAY 12A COIL 120V AUTO STEAM OPTION 1 AND ...

Page 49: ...SECTION G ELECTRIC SCHEMATICS ...

Page 50: ...DE A 1 COOKING SWITCH 5 A 96 HIGH LIMIT 140 F HIGH LIMIT 110 F COOLING FAN 1 5 KW HUMIDITY PROOFER SWITCH HIGH LIMIT STEAM SWITCH STEAM TIMER H3DE OVEN VALVE 8 10 INFINIT SWITCH 2 5 KW EACH ELEMENT PILOT LIGHT 1 5 KW HEAT PILOT LIGHT 4 5 LIQUID LEVEL 40 W BULB 3 4 HP MOTOR T1 L2 T2 L3 T3 L1 T1 T2 L2 L3 T3 T1 L1 T2 L2 T3 L3 DOOR SWITCH 3 5 R1 7 8 R1 VALVE PROOFER JAOP6 60 Hz 1 PHASE 18 05 04 M FAUC...

Page 51: ... ON SW2 DELAY ELECTRONIC TIMER 2 7 8 6 4 1 M COOKING TIMER H5CX MODE A 1 COOKING SWITCH 5 A 96 HIGH LIMIT 140 F HIGH LIMIT 110 F COOLING FAN 1 5 KW HUMIDITY PROOFER SWITCH HIGH LIMIT STEAM SWITCH STEAM TIMER H3DE OVEN VALVE 8 10 INFINIT SWITCH 2 5 KW EACH ELEMENT PILOT LIGHT 1 5 KW HEAT PILOT LIGHT 4 5 LIQUID LEVEL 40 W BULB 3 4 HP MOTOR T1 L2 T2 L3 T3 L1 T1 T2 L2 L3 T3 T1 L1 T2 L2 T3 L3 DOOR SWIT...

Page 52: ...EACH ELEMENT LIQUID LEVEL INFINIT SWITCH 1 5 KW HUMIDITY PILOT LIGHT 1 5 KW HEAT PILOT LIGHT PROOFER SWITCH COOLING FAN HIGH LIMIT 110 F HIGH LIMIT 140 F COOKING SWITCH OVEN VALVE STEAM SWITCH HIGH LIMIT STEAM TIMER H3DE THERMOSTAT COOKING TIMER H5CX MODE A 1 OVEN SWITCH 3 5 R1 7 8 R1 VALVE PROOFER JAOP6 3 PHASES 60 Hz 18 05 04 M FAUCHER 5 2 STANDARD JAOP6_3 1 1 FOR SUPPLY SYSTEMS CONSISTING OF A ...

Page 53: ...KW AT 240 VOLTS EACH ELEMENT LIQUID LEVEL INFINIT SWITCH 1 5 KW HUMIDITY PILOT LIGHT 1 5 KW HEAT PILOT LIGHT PROOFER SWITCH COOLING FAN HIGH LIMIT 110 F HIGH LIMIT 140 F COOKING SWITCH OVEN VALVE STEAM SWITCH HIGH LIMIT STEAM TIMER H3DE THERMOSTAT ON OFF DELAY SELECTOR SWITCH COOKING TIMER H5CX MODE A 1 ON OFF DELAY SELECTOR SWITCH 3 5 R1 7 8 R1 VALVE PROOFER JAOP6 3 PHASES 60 Hz 18 05 04 M FAUCHE...

Page 54: ...LIGHT C1 VA ST VA OL1 7 2 N L1 OL1 95 96 BULB 60 W P1 8 5 1 4 PILOT PILOT SWITCH INFINIT H1 H2 P L1 L2 BULB 60 W FAN C2 C2 LEVEL LIQUID SWITCH PROOFER P1 F1 AV AR L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 C1 C1 A2 A1 ELECTRONIC TIMER THERMOSTAT STEAM TIMER H3DE OVEN VALVE STEAM SWITCH 5 A COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 1 5KW 240V 1 26KW 220V HUMIDITY 1 5KW 240V 1 26...

Page 55: ... VA OL1 7 2 L2 L1 OL1 95 96 BULB 60 W P1 8 5 1 4 PILOT PILOT SWITCH INFINIT H1 H2 P L1 L2 BULB 60 W FAN C2 C2 LEVEL LIQUID SWITCH PROOFER P1 F1 AV AR L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 C1 C1 A2 A1 ELECTRONIC TIMER COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 5 A THERMOSTAT STEAM TIMER H3DE STEAM SWITCH 2 5KW 240V 2 1KW 220V EACH ELEMENT 1 5KW 240V 1 26KW 220V HUMIDITY 1 5K...

Page 56: ... LIGHT C1 VA ST VA BLOWER OL1 7 2 L3 F3 L2 L1 N OL1 95 96 SW 1 3 BULB 60 W P1 8 5 1 4 PILOT HEAT 240V PILOT HUMIDITY 1 5 KW 240V SWITCH INFINIT H1 H2 P L1 L2 BULB 60 W FAN C2 C2 LEVEL LIQUID SWITCH PROOFER P1 C1 F2 F1 AV AR L3 T3 L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 C1 C1 A2 A1 ELECTRONIC TIMER COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 THERMOSTAT STEAM TIMER H3DE STEAM SW...

Page 57: ...C1 C1 A2 A1 C1 C VA OL1 L2 L1 N OL1 95 96 BULB F2 F1 T2 T8 T3 AV AR T1 T4 T5 L3 T3 L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 ELECTRONIC TIMER 5 A DOOR SWITCH 3 4HP MOTOR 2 5 KW EACH ELEMENT THERMOSTAT STEAM TIMER H3DE COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 120 240 2 0A 45A 44A JA6 1 PHASE 60 Hz 25 05 04 M FAUCHER 4 5 STANDARD JA6_1 1 1 120 208 2 0A 51A 49A TOTAL POWER Hz 60...

Page 58: ...140 F 96 THERMOSTAT HIGH LIMIT 500 F 2 5 KW EACH ELEMENT 3 4 HP MOTOR T1 T2 L2 T3 L3 L1 T1 T2 L2 L3 T3 T1 L1 L2 T2 T3 L3 VA VA MODE E OVEN VALVE SWITCH STEAM TV B1 18 A2 A1 15 VL STEAM TIMER H3DE 120 240 1 5A 23A 28A 28A JA6 3 PHASES 60 Hz 25 05 04 M FAUCHER 4 2 4 5 STANDARD JA6_3 1 1 120 208 1 5A 24A 33A 33A TOTAL POWER Hz 60 10 7 Kw WARNING FOR SUPPLY SYSTEMS CONSISTING OF A DELTA SECONDARY TRAN...

Page 59: ... 480V H1 H2 X1 X2 X4 H4 H3 X3 AV AR A1 A2 A1 A2 ST AV AR 2 1 3 4 L3 T3 T5 T4 T1 T3 T8 T2 C1 C1 VA ST VA OL1 N OL1 95 96 BULB 60 W F1 AV AR L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 C1 C1 A2 A1 ELECTRONIC TIMER 5 A THERMOSTAT 2 5KW 240V 2 1KW 220V EACH ELEMENT STEAM TIMER H3DE 3 4HP MOTOR DOOR SWITCH COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 L1 JA6 1 PHASE 50 Hz 21 02 05 M FAUC...

Page 60: ... C1 C1 A2 A1 ELECTRONIC TIMER 5 A LIQUID LEVEL HIGH LIMIT 110 F HIGH LIMIT 140 F COOLING FAN PROOFER SWITCH DOOR SWITCH 40 W BULB INFINIT SWITCH 1 5 KW HUMIDITY PILOT LIGHT 1 5 KW HEAT PILOT LIGHT 2 5 KW EACH ELEMENT 3 4 HP MOTOR OVEN VALVE STEAM SWITCH STEAM TIMER H3DE THERMOSTAT HIGH LIMIT 8 10 96 4 5 2 7 8 6 4 1 M COOKING TIMER H5CX MODE A 1 COOKING SWITCH 3 5 R1 7 8 R1 VALVE PROOFER 120 208 14...

Page 61: ...T1 L1 T1 L2 T2 L3 T3 ELECTRONIC TIMER THERMOSTAT DOOR SWITCH STEAM TIMER H3DE COOKING SWITCH COOKING TIMER H5CX MODE A 1 M 1 4 6 8 7 2 1 5KW HUMIDITY 1 5KW HEAT PILOT LIGHT PILOT LIGHT 2 5KW 208V 2 8KW 220V 2 5KW 240V EACH ELEMENT 3 4HP MOTOR OVEN SWITCH 3 5 R1 7 8 R1 VALVE PROOFER 120 240 16A 35A 42A 29A JAOP6 3 PHASES 60 Hz 25 05 04 M FAUCHER 2 2 5 AUTO STEAM JAOP6_3A 1 1 120 208 14A 37A 46A 33A...

Page 62: ...QUID SWITCH PROOFER P1 F2 F1 T2 T8 T3 AV AR T1 T4 T5 L3 T3 L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 C1 C1 A2 A1 SSR 3 32V DC STEAM SSR 3 32V DC BUZZER BUZZER BAKING ALARM TEMPERATURE TIMER PROGRAMABLE CONTROL T2 LOAD DIGIT SELECT 10 SECOND ON MODEL JAOP6 ONLY L O A D 5 A 3 4HP MOTOR 1 5KW HUMIDITY PILOT LIGHT PILOT LIGHT 1 5KW HEAT 2 5KW EACH ELEMENT T1 OMRON H3CR MODE A 30 SEC T2 DIGIT SEL...

Page 63: ...7 2 L3 F3 L2 L1 N SWITCH DOOR OL1 95 96 BULB P1 8 5 1 4 SWITCH INFINIT H1 H2 P L1 L2 BULB FAN C2 C2 LEVEL LIQUID SWITCH PROOFER P1 F2 F1 AV AR L3 T3 L2 T2 L1 T1 L3 T3 L2 T2 L1 T1 L1 T1 L2 T2 L3 T3 SSR 3 32V DC STEAM L O A D SSR 3 32V DC BUZZER BUZZER BAKING ALARM TEMPERATURE TIMER PROGRAMABLE CONTROL 5 A 3 4HP MOTOR ELECTRONIC TIMER T1 H3CR MODE A 30 SECONDS T2 DIGIT SELECT 10 SECOND ON MODEL JAOP...

Page 64: ...ble for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the period of one year from date of purchase Doyon Equipment Inc hereby guarantees to replace without charge F O B Linière Quebec Canada such part or parts Doyon Equipment Inc will pay the reasonable labor c...

Reviews: