9000DE Series

Delayed Egress Exit Device

Installation instructions

95011817 - 01-2020

EN

 | 

Summary of Contents for 9000DE Series

Page 1: ...9000DE Series Delayed Egress Exit Device Installation instructions 95011817 01 2020 EN ...

Page 2: ...Basic wire connection 5 1 6 Key switch operation for device 6 1 7 Cover end cap and label 7 1 8 Pair of doors 9100 DE Delayed Egress Exit Devices x YR09LFSC Electric Trim Fair Secure x ES100 Power Supply x ES105 Power Transfer x 3914W Sounder x MC 4 DPS x Card Readers 8 1 9 Single Door 9300 DE Delayed Egress Exit Device x YR09LFSC Electric Trim Fail Secure x ES100 Power Supply x ES105 Power Transf...

Page 3: ...36 door opening withoutcutting Can be cutto fit a 32 minimum door opening 85 Decibel Alarm Standard LED Status Indicator Standard Nuisance Alarm Standard DIP Switch Settable Key Switch Control Standard Remote Authorized Egress Standard DIP Switch Settable Remote Re Arm Standard Remote Bypass Standard Door Position Input Standard DIP Switch Settable Auto Reset or Manual Reset DIP Switch Settable Au...

Page 4: ...hten Re install filler in rail and reconnect the small pigtail connectors Use caution not to pinch or bind wires Note IfDIPswitch settings are required to be changed do it now prior to re installing filler in rail See Section below 6310D Cam S3 S1 S3 S1 Underside of filler OFF ON 1 23 4 DIP switch settings should be completed at time of initial installation check local building code Factory settin...

Page 5: ... Specific project or custom wiring diagrams available on re quest consult the dormakabatechinical service department Product intended for indoor use NOTE Always disconnect power prior to making any connections or service It is recommended that the 120VAC power be supplied from an Uninterrupted Power Supply UPS to ensure proper operation during a power failure Always observe proper static discharge...

Page 6: ...flashes green audible alarm is off Initiated by rotating the key clockwise approximately 180 degrees until switch engages hold key until mode is activated DPS input is disabled Re arm Mode From alarm mode unit goes to the delayed egress mode Initiated by rotating the key clockwise approximately 180 degrees until switch engages hold key until mode is activated From the bypass mode unit goes to the ...

Page 7: ...uired order through Service Parts model number CBCLBL Consult with local code authority s having jurisdiction See CBC Secton 1003 1 10 Paragraph 6 KEEP PUSHING THIS DOOR WILL OPEN IN 15 SECONDS ALARM WILL SOUND LED light codes Solid Green Delayed Egress Mode Slow Flashing Green Bypass Mode Fast Flashing Green Authorized Egress Mode Solid Yellow Delay Mode Solid Red Alarm Mode This product meets or...

Page 8: ...uctions 95011817 1135 88 IDE 20 01 2020 Exit Device 8 Pair of door template 1 8 Pair of doors 9100 DE Delayed Egress Exit Devices x YR09LFSC Electric Trim Fair Secure x ES100 Power Supply x ES105 Power Transfer x 3914W Sounder x MC 4 DPS x Card Readers dormakaba ...

Page 9: ...tructions 95011817 1135 88 IDE 20 01 2020 Exit Device 9 Single door template 1 9 Single Door 9300 DE Delayed Egress Exit Device x YR09LFSC Electric Trim Fail Secure x ES100 Power Supply x ES105 Power Transfer x 3914W Sounder x MC 4 DPS x Card Readers dormakaba ...

Page 10: ...www dormakaba us dormakaba DORMA USA Inc T 800 523 8483 ...