PNEUDRI MAXI

MX102 – MX110

USER GUIDE

• GEBRUIKERSHANDLEIDING • ANWENDERHANDBUCH • GUIDE D’UTILISATION 

• KÄYTTÖOPAS • BRUKSANVISNING • BRUKERVEILEDNING • BRUGERVEJLEDNING 

• 

ΕΓΧΕΙΡΙ∆ΙΟ ΧΡΗΣΗΣ 

• GUÍA DEL USUARIO • GUIA DO UTILIZADOR • MANUALE UTENTE 

• 

INSTRUKCJA UŻYTKOWNIKA

• 

POUŽÍVATEĽSKÁ PRÍRUČKA

• 

UŽIVATELSKÁ PŘÍRUČKA

KASUTUSJUHEND 

HASZNÁLATI ÚTMUTATÓ 

• 

LIETOTĀJA ROKASGRĀMATA

• 

VARTOTOJO VADOVAS 

РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ 

• 

NAVODILA ZA UPORABO 

• 

KULLANIM KILAVUZU 

GWIDA  G{ALL-UTENT

Summary of Contents for Pneudri Maxi MX102c

Page 1: ...VISNING BRUKERVEILEDNING BRUGERVEJLEDNING ΕΓΧΕΙΡΙ ΙΟ ΧΡΗΣΗΣ GUÍA DEL USUARIO GUIA DO UTILIZADOR MANUALE UTENTE INSTRUKCJA UŻYTKOWNIKA POUŽÍVATEĽSKÁ PRÍRUČKA UŽIVATELSKÁ PŘÍRUČKA KASUTUSJUHEND HASZNÁLATI ÚTMUTATÓ LIETOTĀJA ROKASGRĀMATA VARTOTOJO VADOVAS РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ NAVODILA ZA UPORABO KULLANIM KILAVUZU GWIDA G ALL UTENT ...

Page 2: ......

Page 3: ...layout 9 3 2 Locating the equipment 9 3 3 Mechanical Installation 9 3 4 Electrical Installation 10 3 4 1 Remote alarm indication 10 3 4 2 MXS DS Hygrometer connection 10 3 4 3 MXA Analogue Outputs 10 4 Operating the equipment 11 4 1 Overview of Controls 11 4 2 Starting the equipment 11 4 3 Stopping the equipment 11 5 Servicing 12 5 1 Cleaning 12 5 2 Service Intervals 12 5 3 Service Kits 13 5 4 Ser...

Page 4: ...ied within this user guide Most accidents that occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules and procedures Accidents can be avoided by recognising that any machinery is potentially hazardous domnick hunter can not anticipate every possible circumstance which may represent a potential hazard The warnings in this manual cover the mos...

Page 5: ... flammable Any fire should be fought by means appropriate to the material causing the fire DRYFIL should be disposed of into a licensed land fill site 5 MX 102 MX110 User Guide Caution Read the User Guide Risk of electric shock Highlights actions or procedures which if not performed correctly may lead to personal injury or death Highlights actions or procedures which if not performed correctly may...

Page 6: ...aterial that dries the compressed air as it passes through One chamber is operational drying whilst the opposite chamber is regenerating by Pressure Swing Adsorption PSA Pressure Swing Adsorption PSA A small amount of the dried compressed air is used to regenerate the spent desiccant bed Dried air at line pressure is expanded to atmospheric pressure through the regenerating column Patented Modular...

Page 7: ...83 Parameter Units MX102 MX110 Supply Voltage V ac 100 240V ac 50 60Hz 10 Power W MXS 18W Max MXA 35W Max Electrical Parameter Units MX102 MX110 Temperature ºC ºF 2 45 35 113 Humidity 50 40ºC 80 MAX 31ºC IP Rating IP65 NEMA 13 Pollution Degree 2 Installation Category II Altitude m ft 2000 6562 Noise dB A 80dBA Environmental 2 1 1 Dimensions Refer to diagram A1 in Annex A for dimensions and weights...

Page 8: ...X Dryer 1 Dryer Test Certificate 1 Hygrometer Test Certificate 1 Only applies to DDS dryers If any items are missing or damaged please contact your local domnick hunter office The following items have been included with your equipment 2 3 Overview of the equipment Refering to diagram A3 in Annex A the major parts of the dryer are as follows Ref Identification Ref Identification 1 Column A Gauge 5 ...

Page 9: ... AA and AO grade filtration is recommended at the inlet to the dryer and an AR grade at the outlet In extreme conditions a water separator WS is recommended at the inlet Ensure that each filter condensate drain is suitably piped away and any effluent is disposed of in accordance with local regulations When the dryers are installed in a multi bank configuration as shown in diagram A6 they should be...

Page 10: ...he alarm circuit should be connected between the COM and the normally closed terminals N C of the relay Under normal operation the relay will be energised and the alarm circuit will be open When a fault occurs e g power failure the relay will de energise causing the alarm circuit to be complete The external alarm circuit should be connected to the dryer at the dedicated terminals as shown in diagr...

Page 11: ... Starting the equipment Warning Start up should be undertaken by a domnick hunter trained qualified and approved service engineer 1 Ensure that the isolation valves on the inlet and the outlet of the dryer are closed 2 Connect the electrical supply to the dryer and verify that the Power On indicator is illuminated 3 Slowly open the isolation valve on the inlet of the dryer Verify that there are no...

Page 12: ...mponent Operation Dryer Check POWER ON indicator is illuminated Dryer Check STATUS FAULT indicators located on the controller Dryer Check for air leaks Dryer Check the pressure gauges during purging for excessive back pressure Dryer Check the condition of electrical supply cables and conduits Dryer Check for cyclic operation Dryer Replace the active exhaust silencers Recommended Service A Filtrati...

Page 13: ...See table below Kit Column Seals MX 608620098 1 Snow storm filler 608201051 1 MX102C MX103C MX103 MX104 MX105 MX106 MX107 MX108 MX109 MX110 20 40 70 20 40 70 20 40 70 20 40 70 20 40 70 20 40 70 20 40 70 20 40 70 70 70 Dryfill AA 9 8 13 12 16 14 21 19 26 24 31 28 36 33 41 37 Dryfill MS 1 7 2 11 2 13 3 17 3 21 4 25 4 29 6 30 37 42 Dryfill WS 2 3 4 5 6 7 8 9 10 11 Seals 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ...

Page 14: ...alfunction Contact domnick hunter approved service agent Desiccant is approaching the end of its useful life Contact domnick hunter approved service agent High pressure drop resulting in low pressure gauge readings or intermittent operation of the downstream equipment The pre after filtration is approaching the end of its operational life Check and replace The dryer is being overflowed or is opera...