background image

Dometic WAECO International GmbH

Hollefeldstrasse 63

D-48282 Emsdetten

dometic.com

787

254

533

25 – 6

0

562

535

225

=

=

480

=

=

47

980

703

277

24

8

25 – 6

0

650

480

535

=

=

=

=

=

A

A

B

B

A

2.

1.

B

400 mm

400 mm

rt

gn

cy

ge

br

ws/sw

ws

or

bl

sw

gr

vt

1

2
3
4
5
6
7
8
9

11

10

12

REMO

TE

C3

Cx

LED

LED

LED

LED

Jx

Jx

1

2

3

4

5

6

7

8

9

10

11

12

1

2

Cx Jx

1

2

1

FreshJet 2200

FreshJet 3200

B

A

1

2

6

9 8

7

10

4

5

2

3

FreshJet 2200

FreshJet 3200

Dometic WAECO International GmbH

Hollefeldstrasse 63

D-48282 Emsdetten

dometic.com

787

254

533

25 – 6

0

562

535

225

=

=

480

=

=

47

980

703

277

24

8

25 – 6

0

650

480

535

=

=

=

=

=

A

A

B

B

A

2.

1.

B

400 mm

400 mm

rt

gn

cy

ge

br

ws/sw

ws

or

bl

sw

gr

vt

1

2
3
4
5
6
7
8
9

11

10

12

REMO

TE

C3

Cx

LED

LED

LED

LED

Jx

Jx

1

2

3

4

5

6

7

8

9

10

11

12

1

2

Cx Jx

1

2

1

FreshJet 2200

FreshJet 3200

B

A

1

2

6

9 8

7

10

4

5

2

3

FreshJet 2200

FreshJet 3200

FreshJet

Chillout ADB

(9105306662, 9600008662)

1

2

6

7

8

3

4

9

0

5

444

5102

118 L

0

2

/

2017

j

bu

bn

cy

ye

gn

gy

og

pk

rd

bk

vt

wh

Blue

Brown

Cyan

Yellow

Green

Grey

Orange

Pink

Red

Black

Violet

White

k

leaflet_figures_ADB2012-2016.fm  Seite 1  Freitag, 26. Januar 2018  10:27 10

Summary of Contents for FRESHJET FJ2200

Page 1: ... Hollefeldstrasse 63 D 48282 Emsdetten dometic com 787 254 533 25 60 562 535 225 480 47 980 703 277 248 25 60 650 480 535 A A B B A 2 1 B 400 mm 4 0 0 m m rt gn cy ge br ws sw ws or bl sw gr vt 1 2 3 4 5 6 7 8 9 11 10 12 REMOTE C3 Cx LED LED LED LED Jx Jx 1 2 3 4 5 6 7 8 9 10 11 12 1 2 Cx Jx 1 2 1 FreshJet 2200 FreshJet 3200 B A 1 2 6 9 8 7 10 4 5 2 3 FreshJet 2200 FreshJet 3200 FreshJet Chillout ...

Page 2: ...AN COND FAN EVAP FAN COMPRESSOR REMOTE J12 UV LAMP RESISTOR 1 2 3 ge gn sw br bl ge gn sw br bl 1 2 3 4 ge gn sw br bl rt PROBE PROBE or or 8 PROBE RESISTOR VALVE 1 2 1 2 1 2 CO PROBE CO PROBE EV PROBE EV PROBE ROOM PROBE ROOM PROBE PROBE PROBE 1 4 2 5 3 6 FJ3200 15 mm 30 mm 45 mm 1 2 3 4 5 6 1 3 4 1 2 3 1 2 7 6 8 5 2 3 4 1 F2AL250V F15AL250V 1 2 3 11 9 10 e d f c g a h b i leaflet_figures_ADB2012...

Page 3: ...FJ 2200 FJ 3200 Air conditioning roof unit Installation Manual EN AIR CONDITIONERS FRESHJET FreshJet ADB2015 I AU book Seite 1 Freitag 26 Januar 2018 9 23 09 ...

Page 4: ...FreshJet ADB2015 I AU book Seite 2 Freitag 26 Januar 2018 9 23 09 ...

Page 5: ...hand over this instruction manual along with it Table of contents 1 Explanation of symbols 4 2 Safety and installation instructions 5 3 Target group for this instruction manual 7 4 Scope of delivery 8 5 Intended use 8 6 Labels 9 7 Installation 9 8 Troubleshooting 18 9 Disposal 19 10 Technical data 21 FreshJet ADB2015 I AU book Seite 3 Freitag 26 Januar 2018 9 23 09 ...

Page 6: ...ction Failure to observe this instruction can cause fatal or serious injury CAUTION Safety instruction Failure to observe this instruction can lead to injury NOTICE Failure to observe this instruction can cause material damage and impair the function of the product NOTE Supplementary information for operating the product FreshJet ADB2015 I AU book Seite 4 Freitag 26 Januar 2018 9 23 09 ...

Page 7: ...ion and repair of the roof air conditioner may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations Inadequate repairs may cause serious hazards For repair service please contact the service centre in your country addresses on the back page Electrical devices are not toys Keep electrical devices out of reach of children or infirm persons ...

Page 8: ...evice as intended The roof air conditioner is not suitable for use in agricultural or con struction vehicles Do not make any alterations or conversions to the device Never drive through automatic car washes when the roof air conditioner is mounted If faults occur in the refrigerant circuit the system must be checked by a specialist company and repaired properly The refrigerant must never be releas...

Page 9: ...o that they cannot be tripped over or damaged A NOTICE Use cable ducts to lay cables through walls with sharp edges Do not lay loose or bent cables next to electrically conductive materials metal Do not pull on the cables 3 Target group for this instruction manual The instructions in this manual are intended for qualified personnel at workshops who are familiar with the guidelines and safety preca...

Page 10: ... machines or similar equipment It will not work properly if exposed to strong vibrations The operating mode of Freshjet is guaranteed for temperature between 0 C and 52 C I No in fig 1 Number Description 1 1 Roof air conditioner 2 1 Air outlet unit 3 1 Fastening frame 4 1 Air filters 5 1 Filter covers 6 1 Seals 7 3 Cable connectors 8 4 Long fastening screws 9 4 Short fastening screws 10 1 Remote c...

Page 11: ...r supplies when working on the roof air conditioner CAUTION Beware of injury Improper installation of the roof air conditioner can result in irreparable damage to the device and put the safety of the user at risk The manufacturer assumes no liability for malfunctions and for the safety of the roof air conditioner especially for injury and or damage to property if the roof air conditioner is not fi...

Page 12: ...ening for the installation of the roof air conditioner can be made without any risk of weakening the construction or cutting power cables Select a flat and sufficiently level area at the centre of the vehicle roof between two longitudinal sections for installation The roof inclination of the installation surface may not exceed 10 The roof air conditioner must be installed above 2 meters Make sure ...

Page 13: ...ble and the 12 24 Vg cable together in the same cable duct Do not lay cables which are loose or bent next to electrically conductive material metal Install an all pole switch with a contact opening width of at least 3 mm on the installation side There are two ways of installing the roof air conditioner Making a new opening chapter Making a new opening on page 12 In this case the opening must be re...

Page 14: ...d B See fig 4 Drill out the corners A Carefully cut out the opening on the roof using a keyhole saw or a similar tool B Make sure no electrical power cables are damaged See fig 5 Before installation check whether the roof hole needs reinforcing Remove the foam according to the width of your reinforcing rails not in scope of delivery A Fit the reinforcing rails B FreshJet ADB2015 I AU book Seite 12...

Page 15: ...elleys Butyl Mastic Bostik ezycaulk butyl sealant or similar products NOTE Existing roof hatch openings in accordance with fig 3 are suitable for installing the roof air conditioner Dispose of all waste material glue silicone and seals separately Observe the disposal guidelines The manufacturer only assumes liability for parts included in the scope of delivery The validity of the warranty expires ...

Page 16: ...rder to feed through the electrical power supply cable Feed the 230 Vw cable through the opening into the vehicle interior If the lighting should be switched on without the use of a 230 Vw voltage supply Connect the cable with the positive terminal and the negative terminal of the vehicle battery Feed the 12 Vg cable through the opening into the vehicle interior DANGER Danger of electrocution Make...

Page 17: ...e seal with the adhesive side on the ADB Fasten the mounting frame 3 on the underside of the roof air conditioner with the 4 screws supplied See fig c A Tighten the screws using a torque spanner and a fastening torque of 2 5 Nm NOTICE Risk of damage Observe the structural strength of the roof of the vehicle The roof of the vehicle must be able to bear the weight of the roof air conditioner The roo...

Page 18: ...1 to a cable connector 2 Item Description 1 230 Vw mains 2 Compressor 3 Fan condenser 4 Fan condenser FreshJet 3200 only 5 Fan evaporator 6 Battery 7 Remote socket 8 Temperature sensor 9 Heating FreshJet 2200 only 10 Heat Pump FreshJet 3200 only 11 Soft Start Freshjet 3200 only Item Description 1 Remote light switch 2 Circuit board in the air outlet unit FreshJet ADB2015 I AU book Seite 16 Freitag...

Page 19: ...ly is not connected To do this proceed as follows Disconnect the 2 pin plug 4 from the socket on the main board Connect the positive cable 5 with the plug Connect the negative cable 6 with the plug Connecting the circuit board See fig e Insert the 12 pin plug 1 in the socket 4 on the circuit board of the air outlet unit Insert the two 2 pin plugs 2 in the sockets 3 on the circuit board 7 6 Install...

Page 20: ...air intake section is clogged up Remove any leaves and other dirt from the ventilation grilles of the roof air conditioner The blower is defective Contact an authorised workshop Water enters the vehicle The condensation water drainage open ings are clogged up Clean the drainage openings for condensation water The seals are damaged Contact an authorised workshop Roof air condi tioner does not switc...

Page 21: ...he appliance during its working life All packing components must be disposed of preferably recycled in compli ance with statutory legislation in the country in which disposal takes place All product components must be disposed of preferably recycled in compli ance with statutory legislation in the country in which disposal takes place For correct disposal the appliance must be consigned to an auth...

Page 22: ...installing commissioning servicing or maintaining equipment regardless of whether it is charged with refrigerant or not decommissioning or disposing of equipment where refrigerant is present Discharge of refrigerant into the atmosphere is against the law Severe penalties apply M If you wish to finally dispose of the product ask your local recycling centre or specialist dealer for details about how...

Page 23: ...er consumption in heating mode 5 2 A 5 5 A Operating temperature range 0 C to 52 C Refrigerant R 407c R 410a Refrigerant quantity 520 g 735 g CO2 equivalent 0 92248 t 1 53468 t Global warming potential GWP 1774 2088 Blower 4 blower levels 1 Automatic mode Protection class IPX4 Max volume of space in the vehicle with insulated walls 25 m 29 m Dimensions L x W x H mm 787 x 562 x 225 mm height above ...

Page 24: ...FreshJet ADB2015 I AU book Seite 216 Freitag 26 Januar 2018 9 23 09 ...

Page 25: ...FreshJet ADB2015 I AU book Seite 216 Freitag 26 Januar 2018 9 23 09 ...

Page 26: ...1573 Mail customerservices dometic co nz NORWAY Dometic Norway AS Østerøyveien 46 N 3232 Sandefjord 47 33428450 47 33428459 Mail firmapost dometic no POLAND Dometic Poland Sp z o o Ul Puławska 435A PL 02 801 Warszawa 48 22 414 3200 48 22 414 3201 Mail info dometic pl PORTUGAL Dometic Spain S L Branch Office em Portugal Rot de São Gonçalo nº 1 Esc 12 2775 399 Carcavelos 351 219 244 173 351 219 243 ...

Reviews: