background image

08/80070/0   ISSUE: 2   Series: A 

These instructions should be read carefully 

and retained for future use. Note also the 

information presented on the appliance.

INSTRUCTION MANUAL

Installation and Operating

Dimplex Saletto (LPPE)

Models: LPP050E / LPP075E / LPP100E / LPP150E

Summary of Contents for Saletto LPP050E

Page 1: ...These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MANUAL Installation and Operating Dimplex Saletto LPPE Models LPP050E LPP075E LPP100E LPP150E ...

Page 2: ...fire risk NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater WARNING THE SURFACES ON THIS HEATER CAN BE HOT The heater carries a warning DO NOT COVER to alert the user to the risk of fire that exists if the heater is accidentally covered DO NOT place combustible items through the heater grille CAUTION Some parts of thi...

Page 3: ...ers combined with the convection effect of electric heaters can cause significant soot deposits to build up on the surface directly above and to the sides of the heater This is not a fault of the heater Extensive burning of candles or smoking in the operating environment of this product can produce heavy discolouration within a few months of use OPERATING WARNINGS IMPORTANT Remember to observe all...

Page 4: ...wiring of the premises through a suitable connection box positioned adjacent to the heater A means for disconnection must be incorporated in the fixed wiring of the premises in accordance with the current wiring regulations The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm Products that are supplied without a plug are for i...

Page 5: ...eaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning us...

Page 6: ...eat output elmax 0 00 0 00 0 00 0 00 At minimum heat output elmin 0 00 0 00 0 00 0 00 In standby mode elSB 0 0005 0 0005 0 0005 0 0005 With open window detection Yes With adaptive start control Yes Type of heat output room temperature control With electronic room temperature control Yes Electronic room temperature control plus week timer Yes With open window detection Yes With adaptive start contr...

Page 7: ...Durable epoxy polyester powder coated steel casing with louvered upward facing grille Advanced controls with capacitive sense technology for total flexibility of heating Finish Colour Metal Chassis Air Outlet Grille Control Moulding Traffic White RAL 9016 Element Compact finned mineral filled sheathed element Installation Wall bracket Safety Thermal cut out Auto reset type Overheat detection Advan...

Page 8: ...upply voltage is the same as that stated on the heater MODEL A B C D E LPP050E 672mm 150mm 746mm 235mm 100mm LPP075E 672mm 150mm 746mm 235mm 100mm LPP100E 803mm 150mm 877mm 235mm 100mm LPP150E 1068mm 150mm 1142mm 235mm 100mm General Information Wall Mounting Instructions IMPORTANT The wall bracket supplied with the heater must be used and the heater must be installed in the correct orientation The...

Page 9: ... slots in the back with bracket hooks 4 Press the top of the heater into locked position and ensure the clips on the top are engaged WARNING This product is heavy and care should be taken in installation C 150mm min 150mm min 150mm min D Minimum mounting clearance 300mm 170mm min E Shelf Obstruction The minimum distance from the shelf should be 170 minimum if the shelf is wider than 50mm or 50 min...

Page 10: ...e heating periods If the room temperature is above this temperature then the heater will not operate The heater leaves the factory with this temperature set at 21 C which represents a typical comfortable room temperature If you require a different room temperature use either or until the display shows the temperature you require Timer Modes Your Dimplex LPPE Panel comes pre programmed with four ti...

Page 11: ...l go off until the beginning of the next Comfort On period Advance Boost The Advance button is also used to enter the boost mode which provides temporary heating for one two three or four hours Press the Advance button twice to begin a one hour boost Continue pressing the Advance button to enter the longer boost periods NOTE Advance Boost only works when not in timer mode Out All Day Comfort On Ou...

Page 12: ...s 5 Enter Button 6 Advance Button 7 Heating Status NOTE Should the heater fail to operate this may be due to the room temperature being higher than the thermostat setting NOTE Your heater may produce some noise during operation This noise is caused by the expansion and contraction of the element as it changes temperature and is normal for this type of product Whilst the noise produced is usually v...

Page 13: ... The timed periods during which the heater is providing heat are defined as Comfort On this is displayed at the bottom of the screen Outside of heating periods the heater will not deliver heat and these periods are called Comfort Off While constant heat modes are active the mode of operation is displayed at the bottom of the screen e g Manual 6 The Advance button overrides the heating settings and...

Page 14: ... The heater incorporates a real time clock with calendar function The time clock has a battery backup that will keep the clock running in the event of a mains power outage To adjust the time or date follow the steps below Press the Menu button Select Date Time by pressing the Enter button Press and to select the correct day of the month and press Enter to select Repeat this operation until the dat...

Page 15: ...ed 07 00 until 08 30 17 30 until 22 00 3 HomeAllDay pre programmed hasthefollowingpresettimesMondaytoSunday which can be altered if desired 08 00 until 21 00 4 Holiday pre programmed for 7 days at 10 C set the number of days required from 1 to 255 and the temperature required 7 C is advised if you just want to protect the property from frost while you are away The heater can also maintain a consta...

Page 16: ...xt to move to the following heating period When a day is complete the following options are available Save Saves times for one day Copy Next Copy times from the day shown to the following day Copy All Copy times from the day shown to all seven days Clear Remove all times from the day shown Clear All Remove all times for all seven days NOTE Once modified a programme must be selected if you want to ...

Page 17: ...n the period starts If EcoStart ES is disabled the heater will not operate until the beginning of the heating period This should be taken into consideration when setting the heating periods See page 19 for instruction on enabling disabling EcoStart The Advance function allows the active timer schedule to be changed temporarily When a timer has been selected the Advance function is used to begin th...

Page 18: ...ight saving time If no adjustment is required then select none Auto Lock Enable or disable the auto lock feature This feature locks the interface if left inactive for longer than one minute To unlock the appliance press and hold Back and Enter for two seconds Sound Audio feedback can be enabled or disabled Service Info Service information is displayed Temp Units Choose whether your unit displays d...

Page 19: ...the user to select the Max Temp to adjust the maximum temperature range of the appliance Setback allows the user to select a background temperature setting when the product is not in a Timer Mode Comfort On period Open Window detection OW when enabled allows the heater to reduce the target room temperature limiting energy waste Enabled as default when an open window is detected EcoStart ES to achi...

Page 20: ...e to control the room to a desired temperature During a runback period the set point can be adjusted by the user however it is possible to assign a maximum set point limit during the runback mode setup Once the runback period has elapsed the appliance will switch into Comfort off mode or into setback mode if enabled To activate a runback period the user must press the Advance button There will be ...

Page 21: ...iance functionality will be enabled 12 00 Comfort Off Runback lock Change code Setback Max Temp Runback Runback Disable Settings Enable Runback lock 0000 Enter code Advanced Runback Lock SP Config NOTE The default PIN code is 0000 the password can be changed from within the runback lock mode menu Runback Mode Settings Changing the PIN code It is possible to set a user defined runback lock PIN code...

Page 22: ...nabled 12 00 Comfort Off Runback lock Enter code 0000 Runback lock Change code Setback Max Temp Runback Maximum Temperature A maximum temperature limit for the room during runback can be applied This will restrict the users ability to increase the room temperature beyond a set value during a runback period The maximum temperature can be set by selecting Max Temp in the Runback lock settings menu T...

Page 23: ...r advisable to keep the room well ventilated Cleaning WARNING ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER Before commencing cleaning isolate the heater from the electrical supply and allow it to cool The outside can be cleaned by wiping it over with a soft dry cloth Do not use abrasive cleaning powders or furniture polish as this can damage the surface finish To release the ...

Page 24: ... heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms you heat most 6 Treat your hot water tank Give it a jacket An insulating jacket for hot water tanks costs only a few pounds and pays for itself within months Fit one that s at least 75mm 3 thick and yo...

Page 25: ...ce a problem with your Dimplex product please call the Helpline on 0344 879 3588 or visit https www gdhv com contact us and complete the online form For ROI please email serviceireland glendimplex com or call 353 0 1 842 833 We will need details of your Dimplex product its serial number and a description of the fault which has occurred You can find the model number and serial number for your Dimpl...

Page 26: ...of the product if later always provided the original receipt has been retained and is produced as proof of purchase You must provide to Dimplex or its authorised agents on request the original receipt as proof of purchase and if required by Dimplex proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair work under the Di...

Page 27: ...27 ...

Page 28: ...ghts reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex This product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC ...