background image

DGP-641 LCD Keypad V1.3

Programming Guide

P

ROGRAMMING

 M

ETHOD

 

To view the keypad’s serial number, press and hold the 

[0]

 key,

then enter the

 [

INSTALLER

 

CODE

]

 and enter 

[000]

. We recommend

that you use this sheet to keep track of which sections were
programmed and how. This module can also be programmed using
the control panel’s Broadcast Programming Feature (see 

Digiplex

Installation & Reference Manual

).

P

ROGRAMMING

 S

ECTIONS

In the following tables and sections, any value represented in 

bold

is the default setting.

SECTION [006]

 

Confidential Mode Timer (005-255 seconds)
___/___/___ (default = 120)

SECTION [007]

 

PGM Timer (000-255 

see option [3] in section [005]

)

___/___/___ (default = 005)

SECTION [008]

 

PGM Activation Event: 

PGM Table in Digiplex Programming Guide

___/___ [1  2  3  4  5  6  7  8] (default = 0 / 0 all off)

SECTION [009]

 

PGM Deactivation Event: 

PGM Table in Digiplex Programming Guide

___/___ [1  2  3  4  5  6  7  8] (default = 0 / 0 all off)

M

ESSAGE

 P

ROGRAMMING

 

Each section from 

[101] 

to

 [249]

 contains one message with a

maximum of 16 characters. For more details and to record any
changes, use the 

DGP-641 LCD Programming Guide

Section 

[101]

 to 

[148]

 = Zone 01 to Zone 48 respectively

Section

 [149]

 to

 [244]

 = Code 01 to Code 96 respectively

Section 

[245] 

= Paradox Family

Section

 [246]

 to 

[249]

 = First, Second, Third, & Fourth Area

After entering the section corresponding to the desired message,
the message can be re-programmed to suit your installation needs
as detailed in Table 1. For example, section [101] 

“ZONE 01” 

can

be changed to 

“FRONT DOOR”

.

STEP 1: Press and hold the 

[0]

 key

STEP 2: Enter the 

[

INSTALLER

 

CODE

]

 

STEP 3: Enter section 

[953]

 

STEP 4: Enter the keypad’s 8-digit 

[

SERIAL

 

NUMBER

]

STEP 5: Enter the 3-digit 

[

SECTION

]

 you want to program

STEP 6: Enter the required data

SECTION [001]: Partitioning

Option

OFF

ON

[1]

Partition 1

 l

 Disabled

 l

 

Enabled

[2]

Partition 2

 l

 Disabled

 l

 

Enabled

[3]

Partition 3

 l

 Disabled

 l

 

Enabled

[4]

Partition 4

 l

 Disabled

 l

 

Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [002]: General Options

Option

OFF

ON

[1]

Display Code Entry

 l

 

Disabled

 l

 Enabled

[2]

Display Exit Delay

 l

 

Disabled

 l

 Enabled

[3]

Display Entry Delay

 l

 

Disabled

 l

 N/A

[4]

Confidential Mode

 l

 

Disabled

 l

 Enabled

[5]

To Exit Confidential Mode

 l

 

Enter Code

 l

 Press Button

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [003]: General Options

Option

OFF

ON

[1]

Muting

 l

 

Disabled

 l

 Enabled

[2]

Exit Delay Beep

 l

 Disabled

 l

 

Enabled

[3]

Not used

 l

 N/A

 l

 N/A

[4]

Chimed Zone Closure

 l

 

Disabled

 l

 Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [004]: Beep on Trouble

Option

OFF

ON

[1]

System & Clock Trouble Beep

 l

 

Disabled

 l

 Enabled

[2]

Communicator Trouble Beep

 l

 

Disabled

 l

 Enabled

[3]

Module & Bus Trouble Beep

 l

 

Disabled

 l

 Enabled

[4]

All Zone Trouble Beeps

 l

 

Disabled

 l

 Enabled

[5]

Not used

 l

 N/A

 l

 N/A

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [005]: PGM Options

Option

OFF

ON

[1]

PGM State is Normally

 l

 

Open

 l

 Closed

[2]

PGM Timed Mode

 l

 

Disabled

 l

 Enabled

[3]

PGM Base Time

 l

 

1 Second

 l

 1 Minute

[4]

PGM Override

 l

 

Disabled

 l

 Enabled

[5]

Keypad Tamper

 l

 

Disabled

 l

 Enabled

[6]

Not used

 l

 N/A

 l

 N/A

[7]

Not used

 l

 N/A

 l

 N/A

[8]

Not used

 l

 N/A

 l

 N/A

Reviews: