background image

 

 

  

 

Dipl. Ing. K. Dietzel GmbH 

Leedenstraße 10 

04626 Beerwalde

 

 

 

 

 

 

Phone: +49 (36602) 140-0 

Mail: [email protected] 

www.dietzel-hydraulik.de  

 

 

 

 

Page 1 of 4 

Revised as of: 03/2014 

Nicky Groß   

 

 

 

User manual for Hose safety Catch 

 

Components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description of function 

In the event that the connection between the hose and the fitting comes loose under pressure, the 

hose safety wire prevents the hose from throwing (whipping) because the catch wire tightens under 

tension. The length of the catch wire is to be laid out so that the hose can slide out of the fitting 

(pressure release).  

Application/Conditions of use

 

The hose safety catch has been developed and tested with reference to the following standards:  

DIN EN 853, DIN EN 856, EN 857, SAE J517  

DIN 2353, SAE J518  

These contain references to hoses and fittings.   

 

Minimum lengths of hose when fitted both sides (left/right) of the catch:  

Hose nominal diamters  DN 06 to 31:  600 mm 

DN 38 to 51:  700 mm 

DN 60 to 76:   1000 mm 

 

It is essential to ensure that the use complies with these standards. Guarantee claims are invalid 

when these assembly instructions are not complied with. The maximum operating pressure of the 

hose must not be exceeded.  In case of use at higher operating pressures, no liability will be 

accepted for sufficient strength of the system. 

 

 

 

Hose clamp (with 

elastomer insert)) 

Wire 

guide 

Catch 

wire 

Velcro 

strap 

Fixing 

bracket 

Summary of Contents for Hose safety Catch

Page 1: ...ditions of use The hose safety catch has been developed and tested with reference to the following standards DIN EN 853 DIN EN 856 EN 857 SAE J517 DIN 2353 SAE J518 These contain references to hoses and fittings Minimum lengths of hose when fitted both sides left right of the catch Hose nominal diamters DN 06 to 31 600 mm DN 38 to 51 700 mm DN 60 to 76 1000 mm It is essential to ensure that the us...

Page 2: ... 45 mm between hose clamp and the end of the ferrule Fig 1 If the fitting has an elbow you must also take the position of the wire guide to the pipe bend into account Fig 2 Tighten the bolt on the clamp until the rubber insert elastomer profile is secure on the hose but still allows the hose to swell according to the permissible operating pressure Lay the catch wire on the hose Fig 3 Take the ends...

Page 3: ... 2014 Nicky Groß Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Operational safety noticesSicherheitshinweise für den Betrieb When assembling the hose safety catch onto hoses which move Rubbing or grazing to the skin through safety components Pinching of hands fingers through the changing position of the wire Practice increased caution in the danger area ...

Page 4: ...d does not have any damage In case of damage to individual parts the entire hose safety catch must be replaced The same applies when the safety catch comes into action after the failure of a hose connection EC conformity declaration for machines directive 2006 42 EC The manufacturer hereby declares Dipl Ing K Dietzel GmbH Leedenstraße 10 04626 Beerwalde That the safety device for the holding of a ...

Reviews: