background image

 

 

 

 

 

OPERATING/SAFETY ORIGINAL INSTRUCTIONS

 

DBR-32HD 

REBAR STRAIGHTENER 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO REDUCE THE RISK OF INJURY, YOU MUST READ AND   

UNDERSTAND THIS INSTRUCTIONS 

 

 

 

 

                                                                       

 

                       

                                               

 

                                                                       

 

                                                           

 

Capital Machinery Sales Pty Ltd

www.capitalmachinery.com.au

Call 1800 706620

Summary of Contents for DBR-32HD

Page 1: ... SAFETY ORIGINAL INSTRUCTIONS DBR 32HD REBAR STRAIGHTENER TO REDUCE THE RISK OF INJURY YOU MUST READ AND UNDERSTAND THIS INSTRUCTIONS Capital Machinery Sales Pty Ltd www capitalmachinery com au Call 1800 706620 ...

Page 2: ... OPERATING INSTRUCTIONS 8 BENDING HOOK 8 WARM UP 8 OPERATION 8 PUSH 9 PULL 9 POINTS OF ATTENTION 10 CLEANING 10 OIL LEVEL CHECK ADD OIL 11 BOLT TIGHTNESS 12 CARBON BRUSHES 12 OVERHAUL 12 THESE TOOLS ARE FOR INDUSTRIAL USE ONLY Capital Machinery Sales Pty Ltd www capitalmachinery com au Call 1800 706620 ...

Page 3: ...tric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded Do not expose power tools to rain or wet conditions Water entering a power tools will increase the risk of electric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the powe...

Page 4: ... these devices can reduce dust related hazards Keep handles dry clean and free from oil and grease Slippery hands cannot safely control the power tool POWER TOOL USE AND CARE Do not force the power tool Use the correct power tools for your application The correct power tool will do the job better and safer at the rate for which it was designed Do not use the power tool if the switch does not turn ...

Page 5: ...by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained SPECIFIC SAFETY RULES Hold power tool by insulated gripping surfaces when performing an operation where the cutting tool may contact hidden wiring or its own cord Contact with a live wire will make exposed metal parts of the tool live and shock the operator Use clamp...

Page 6: ...ding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal Your tool must be plugged into an appropriate outlet properly installed and grounded in accordance with all codes and ordinances Double Insulated Tools Tools with Two Plugs Tool marked Double Insulated do not require grounding...

Page 7: ...ECIFICATION MODEL DBR 32HD Power Supply 100V 115V 230V AC Wattage 2000W Motor Double insulated motor Max rebar dia 32mm Bending speed 12 sec 90 Bending radius R 25mm Max tensile strength 620 N mm Max Bending angle 94 D13mm 1 2 rebar Dimensions LxWxH 686 x264x 217 mm Weight 27 8 Kg 2 2 3 4 5 7 8 9 10 11 1 6 Capital Machinery Sales Pty Ltd www capitalmachinery com au Call 1800 706620 ...

Page 8: ... and shoot out especially if the material is harder that those specified Exceeding designated material specifications greatly increase this risk and will also damage the tool Do not attempt to use the tool for rebars harder thicker or thinner than those specified PRE SUE CHECKS 1 WARNING Do not expose the tool to rain or wet conditions Water entering a power tools will increase the risk of electri...

Page 9: ...or as well as damage to the tool ROLLERS 2 Change rollers according to rebar diameter Rollers 50 50 0mm are for D25 0 to D32 0mm rebars Rollers 68 68 0mm are for D13 0 to D20 0mm rebars WARM UP 3 Make sure the unit is plugged into the proper outlet 100V 115V or 230V 50 60Hz Please check the voltage of your DBR 32HD 4 In cold weather warm up the tool for 30 60 seconds so that the hydraulic oil reac...

Page 10: ... than the distance of two rollers 7 Pull trigger switch to extend bending hook CAUTION Keep hands away from moving parts while operating PUSH Straightening Bending Advance or retract the piston so that the bending hook is in a suitable starting position Set the mode control lever to PUSH and fit the rebar Pull the trigger switch until the rebar is at the desired angle PULL Straightening Bending Ad...

Page 11: ...nd motor is an unusually hot check carbon brush CLEANING Clean your tool every day preferably immediately after use WARNING To avoid accidents always disconnect the tool from the power supply before cleaning or performing any maintenance 1 Wipe or brush away dirt and metal filings Keep housing and piston free of dirt and iron filings Pay particular attention to the lower half of the piston where d...

Page 12: ...M 32 Shell or DTE 24 Mobil 6 After topping up extract air from system Gently tilt tool lengthwise and return it to a level position Top up again and tilt in the opposite direction Repeat this process until all air has been extracted CARE Tool cannot function properly if oil contains air bubbles 7 Replace oil plug The operation is now complete 8 If oil level is too low Remove Air bag cover A B 9 Fi...

Page 13: ... every two months Nominal brush life is 200 hours CARE Worn brushes will result in power loss cause the motor to run hot and irreparably damage the armature 1 Disconnect tool from electrical outlet 2 Remove Tail cover Unscrew both brush caps and pull out carbon brushes 3 Replace brushes if less than 6mm in length We recommend the automatic stop carbon brush for replace Standard carbon brush Parts ...