ELECTRONIC PUMP CONTROLLER

PRESFLO

®

 is a device that 

starts and stops the pump to 
which it is fitted, thus replacing 
traditional pressure switch / 
surge tank systems.
The pump is started when, as 
a tap is turned on, the pressure 
within the system drops below 
the “start-up pressure” (Pm), 
and is stopped when the flow 

USER’S MANUAL

rate required is zero or less 
than the “shut-off flow rate” 
(Qa). 
The electronics of PRESFLO

®

 

protects the pump against 
abnormal running conditions 
such as dry running, repeated 
start-ups due to leaks in the 
system or overcurrents.

Technical specifications

Losses

- Voltage: ~ 230 V / ~ 115 V - Frequency: 50-60 Hz 
- Current: 12A, max 16A for 3 sec.  
- Protection grade: IP 65 
- Start-up pressure ( Pm ): 1÷5 Bar (15-70 psi)
- Shut-off flow rate ( Qa ): 2 litres/min (0,5 gpm)
- Connections: 1”M BSP / 1”M NPT 
- Operating pressure: 8 bar (120 psi) 
- Bursting pressure: 24 bar (350 psi) 
- Weight: 1600 g
- Protection against: dry running 
  ( automatic restart), 
  repeated start-ups, 
  overcurrents

Before installing

, the product, check 

that the RATINGS correspond with those 
required.

Operating conditions

A. Compatible/non compa-
tible fluids 

PRESFLO

®

 is suitable for use 

with clean water and chemical-
ly non-aggressive liquids. If the 
fluid contains impurities, a filter 
should be fitted upstream.

B. Environmental conditions

PRESFLO

®

 should not be used 

where there is the risk of an 
explosion. The temperature 
of the location should range 
between 0°C and 40°C, and 
the humidity should not exceed 
90%.

C. Power supply

Make sure that the variation 

in the power supply is never 
more or less than 10 % of the 
RATING value. 
Higher values may cause 

damage to the electronic 
components.
PRESFLO

®

 can only be used 

with single-phase pumps.

Working area

Flow rate

Pressure

Shut-off flow rate

Start-up pressure

Qa

Pm

Safety regulations 

Before installing or using 
PRESFLO

®

, read this manual 

carefully and thoroughly.
The pump should be installed 
and serviced by qualified per-
sonnel, responsible for making 
the hydraulic and electrical 
connections in compliance with 
the relevant regulations.
DGFLOW

®

 shall not be held lia-

ble for any damage relating to, 
or resulting from, an improper 
use of the product, or for any 
damage relating to, or resulting 
from, servicing or repairs carri-
ed out by unqualified personnel 
and/or with non-OEM spare 
parts. 
The warranty, which is valid 
for 24 months from the date 
of purchase, will no longer be 
applicable should the product 
suffer damage as a conse-
quence of the use of non-OEM 
spare parts, tampering or 
improper use. 
When starting the installation, 
check the following:

- the power supply is switched 
off.
- the power lines can withstand 
the maximum current.
- the cable bushings and circuit 
board cover have been properly 
assembled and secured ( see 
Electrical Connections ).
- the power supply is fitted with 
regulation earthing and safety 
devices.

When servicing the product, 
check the following:
- the system is not pressurised 
(turn a tap on)
- the power supply is switched 
off.

Emergency Stop

When in use, the pump can 
be stopped in the event of an 
emergency: 
press STOP/RESTART.  

PRESFLO

®

 is put OUT OF 

SERVICE.

For no reason

, disassemble 

the water accumulator with the 
system pressurized.

Cover

Water accumulator

To set the running pres-
sure (Pm) and the max. 
motor current (I max.), see 
Configuration paragraph.

Water accumulator pressure.

Should be inflated to a value 0,5 bar lower than 
the running pressure.

0             50            100          150         200 l/min

0        5        10      15 

m H

2

O

Manufacturer’s 
settings

Other      selectable settings

RU

EN

FR DE

IT

ES

2

 l/min (0,5 gpm)

5,0

 bar

(75 psi)

 
 
 
 
2,0

 bar

(30 psi)

1,0

 bar

(15 psi)

Summary of Contents for PRESFLO MULTI

Page 1: ...nic components PRESFLO can only be used with single phase pumps Working area Flow rate Pressure Shut off flow rate Start up pressure Qa Pm Safety regulations Before installing or using PRESFLO read this manual carefully and thoroughly The pump should be installed and serviced by qualified per sonnel responsible for making the hydraulic and electrical connections in compliance with the relevant reg...

Page 2: ...It occurs when there is no water After 15 seconds PRESFLO stops the pump and indicates an ERROR message PRESFLO AUTOMATICALLY tries to resume NORMAL SERVICE at intervals of increasing time 1 15 30 60 minutes and successively once every hour 24 H for AU NZ If PRESFLO detects any pressure and or flow NORMAL SERVICE is resumed otherwise the pump is stopped again until the next attempt is made A MANUA...

Page 3: ... turned on PRESFLO detects a flow the assembly pressure is normally higher than the START UP pressure but it may also be lower Press briefly or hold down the pump is stopped and put OUT OF SERVICE For instruc tions on how to reactivate the pump see point 3 The taps are turned off Sif there is no flow for a few seconds the pump is stopped NORMAL SERVICE the pump is running PRESFLO has detected that...

Page 4: ...be adjusted continuously from 4 to 12 A trimmer B 4 When you finish adjustment close the cover CODE V Hz I max B V00103101 230 50 60 16 A SN 1506003 1 2 3 6 5 4 8 7 Exploded view of spare parts Attention when orde ring spare parts always state the position n from the diagram below and the product code number found in the pressure flow regulator technical data table Article Version Dimensions Off F...

Reviews: