Hybrid Inverter

User Manual

R

Summary of Contents for SUN-3.6K-SG01/03LP1-EU

Page 1: ...Hybrid Inverter User Manual R ...

Page 2: ...ist 3 2 Mounting instructions 3 3 Battery connection 3 5 PV Connection 3 4 AC Input Output Connection 4 OPERATION 4 1 Power ON OFF 4 2 Operation and Display Panel 5 LCD Display Icons 5 1 Main Screen 5 2 Solar Power Curve 01 01 04 04 16 17 18 27 3 6 CT Connection 3 7 Earth Connection mandatory 3 8 WIFI Connection 3 9 Wiring System for Inverter 3 10 Single phase parallel connection diagram 3 11 Thre...

Page 3: ...important to correctly operate this inverter Be very cautious when working with metal tools on or around batteries Dropping a tool may cause a spark or short circuit in batteries or other electrical parts even cause an explosion Please strictly follow installation procedure when you want to disconnect AC or DC terminals Please refer to Installation section of this manual for the details Grounding ...

Page 4: ...tion Buttons 4 Battery input connectors 5 RS 485 Port 6 CAN Port 7 DRMs Port 8 Parallel port 9 Function Port 10 Generator input 16 WiFi Interface 11 Load 12 Grid 13 Power on off button 14 DC Switch 15 PV input with two MPPT 1 2 5 9 10 11 12 14 15 16 13 7 6 3 4 8 02 ...

Page 5: ... design for optimized battery performance With limit function prevent excess power overflow to the grid Supporting WIFI monitoring and build in 2 strings of MPP trackers Smart settable three stages MPPT charging for optimized battery performance Time of use function Smart Load Function Parallel function On Grid Off Grid The following illustration shows basic application of this inverter It also in...

Page 6: ...wing package No Description Qty 1 2 3 4 5 SUN 3 6K 5K SG01 03LP1 EU hybrid inverter Stainless steel mounting screws M6 12 Stainless steel expansion bolts M8 80 User manual WiFi plug 1 2 4 1 1 1 2 3 6 7 8 9 4 5 04 Grid Backup Load WiFI GPRS phone Cloud services On Grid Home Load Generator ATS Grid connected Inverter Smart Load CT Battery Solar Wind CT AC cable DC cable ...

Page 7: ...ere highly flammable materials are stored Not in potential explosive areas Not in the cool air directly Not near the television Antenna or antenna cable Not higher than altitude of about 2000 meters above sea level Not in environment of precipitation or humidity 95 Please select a vertical wall with load bearing capacity for installation suitable for installation on concrete or other non flammable...

Page 8: ...mm 500mm Inverter should vertically installed as shown installation procedure show below 1 Position the bolts on the appropriate wall according to the bolt positions on the mounting shelves and mark the holes On the brick wall the installation must be suitable for the expansion bolt installation 2 Ensure that the position of the installation holes on the wall A B C D are the same position of the i...

Page 9: ...red between the battery and the inverter In some applications switching devices may not be required but over current protectors are still required Refer to the typical amperage in the table below for the required fuse or circuit breaker size Model 3 6 5KW Wire Size 3AWG Cable mm 2 25 Torque value max 5 2Nm Inverter hanging plate installation 07 ...

Page 10: ... fit the battery connectors in then fasten the bolt by the screwdriver make sure the bolts are tightened with torque of 5 2 N M 2 Nm in clockwise direction make sure polarity at both the battery and inverter is correctly connected 3 In case of children touch or insects go into the inverter Please make sure the inverter connector is fasten to waterproof position by twist it clockwise Installation m...

Page 11: ...3 3 2 Battery temperature connection 1 2 Temp CT 09 ...

Page 12: ... sure to open DC protector or disconnector first 2 Remove insulation sleeve 10mm length unscrew the bolts insert the AC input wires according to polarities indicated on the terminal block and tighten the terminal screws Make sure the connection is complete All wiring must be performed by a qualified personnel It is very important for system safety and efficient operation to use appropriate cable f...

Page 13: ...tallation Otherwise this inverter will trigger overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner Before connecting to PV modules please install a separately DC circuit breaker between inverter and PV modules It is very important for system safety and efficient operation to use appropriate cable for PV module connection ...

Page 14: ...verter 2 Open circuit Voltage Voc of PV modules should be higher than min start voltage It is requested to use PV junction box with surge protection Otherwise it will cause damage on inverter when lightning occurs on PV modules Chart 3 5 PV Input Voltage V Inverter Model 3 6KW 5KW 370V 100V 500V 125Vdc 425Vdc PV Array MPPT Voltage Range No of MPP Trackers No of Strings per MPP Tracker 2 1 1 12 ...

Page 15: ...und cable shall be connected to ground plate on grid side this prevents electric shock if the original protective conductor fails For the configuration of Wi Fi Plug please refer to illustrations of the Wi Fi Plug N L PE White wire Inverter 3 4 Black wire Grid L N CT 3 4 13 ...

Page 16: ... 9 Wiring System for Inverter Battery Solar Breaker Inverter CAN Breaker Breaker Earth BAR 3 4 CT Generator Microinverter Smart Load L Arrow pointing to grid N PE Breaker or or Loads Loads Grid Ground 14 ...

Page 17: ...allel Master Slave Modbus SN 02 A Phase B Phase C Phase Advanced Function Paral Set3 Parallel Master Slave Modbus SN 03 A Phase B Phase C Phase Advanced Function Paral Set3 Master inverter Slave Inverter Slave Inverter DSM 485 DSM CAN DRMs Parallel A Parallel B Grid Load L N PE Inverter Inverter No 3 slave Ground Inverter No 2 slave Inverter No 1 master Battery pack ...

Page 18: ...hase Parallel Inverter Parallel Master Slave Modbus SN 01 A Phase B Phase C Phase Advanced Function Paral Set3 Parallel Master Slave Modbus SN 02 A Phase B Phase C Phase Advanced Function Paral Set3 Parallel Master Slave Modbus SN 03 A Phase B Phase C Phase Advanced Function Paral Set3 A Phase Master inverter B Phase Master inverter C Phase Master inverter DSM 485 DSM CAN DRMs Parallel A Parallel ...

Page 19: ...nd Display Panel The operation and display panel shown in below chart is on the front panel of the inverter It includes four indicators four function keys and a LCD display indicating the operating status and input output power information Chart 4 1 LED indicators LED Indicator DC AC Normal Alarm Green led solid light Green led solid light Green led solid light Red led solid light PV Connection no...

Page 20: ...ton you can enter into the system setup screen which including Basic Setup Battery Setup Grid Setup System Work Mode Generator port use Advanced function and Li Batt info 4 The main screen showing the info including Solar Grid Load and Battery Its also displaying the energy flow direction by arrow When the power is approximate to high level the color on the panels will changing from green to red s...

Page 21: ... Main Screen Solar Page Solar Graph Grid Graph BMS Page Load Graph Battery Setting System Work Mode Grid Setting Gen Port Use Basic Setting Advanced Function Device info Grid Page Inverter Page Battery Page Load Page System Setup 19 ...

Page 22: ...h Phase Back up consumption for Day and Total Press the Forced button will forced open the smart load While GEN PORT utilized as Smart load output Power 0W Stand by 0 0Hz Energy CT1 0W L1 0V L2 0V BUY Today 0 0KWH Total 8 60 KWH Today 2 2KWH Total 11 60 KWH SELL LD1 0W CT2 0W LD2 0W Grid This is Grid detail page Press the Energy button will enter into the power curve page Status Power Frequency CT...

Page 23: ... 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 6 7 8 9 10 11 12 13 14 15 Curr Volt Curr Temp SOC Energy Charge Fault Sum Data Details Data Li BMS Solar power curve for daily monthly yearly and total can be roughly checked on the LCD For more accuracy power generation pls check on the monitoring system Click the up and down arrow to check power cur...

Page 24: ...09 15 17 Batt Mode Lithium Use Batt V Battery Setting Activate Battery Max A Charge Batt Capacity Max A Discharge 40A 40A 400Ah Batt Mode Use Batt No Batt Lithium Battery Max A charge 0 120A Max A Discharge 0 120A Activate Battery Enable AGM Battery Max A charge 0 120A Max A Discharge 0 120A Activate Battery Enable Batt Mode Lithium Batt Mode Use Batt V or Use Batt V Batt Capacity 50 2000Ah No Bat...

Page 25: ...0 No use Just for customization A 40A It indicates the Current that the Grid charges the Battery Grid Charge It indicates that the grid charges the battery Grid Signal Disable Gen Max RunTime It indicates the longest time Generator can run in one day when time is up the Generator will be turned off 24H means that it does not shut down all the time Gen DownTime It indicates the delay time of the Ge...

Page 26: ...rge Gen 01 00 05 00 09 00 13 00 17 00 21 00 5 00 9 00 13 00 17 00 21 00 01 00 Power 5000 5000 5000 5000 5000 5000 49 0V 50 2V 50 9V 51 4V 47 1V 49 0V Work Mode2 Work Mode Zero Export To Load Zero Export To CT Max Sell Power Energy pattern BattFirst LoadFirst System Work Mode Solar Sell Solar Sell 5000 Zero export Power 500 Selling First Work Mode1 Work Mode Selling First It means that the excess e...

Page 27: ...stop 0 0V 0 0 s V2 0 0V Q2 0 00 V3 0 0V Q3 0 00 V4 0 0V Q4 0 00 0 0 s Grid Set3 Grid Setting L HVRT L HFRT HV2 0 0V HV1 0 0V LV1 0 0V LV2 0 0V LV3 0 0V 0 16S 0 16S 0 16S 0 16S 0 16S HF2 0 00HZ HF1 0 00HZ LF1 0 00HZ LF2 0 00HZ 0 16S 0 16S 0 16S 0 16S Grid Set4 Please select the correct Grid Mode in your local area If you are not sure please choose General Standard Please select the correct Grid Typ...

Page 28: ... connects grid the ATS port will output 230Vac and it is used to cuts off Earth Neutral load port N line bond via connect external relay When the inverter disconnects from the grid ATS port voltage will be 0 and the Earth Neutral bond keeps on More details please refer to left picture external relay L N ATS load port Inverter shell Ground cable 230V coil closed contact Generator Input use Generato...

Page 29: ... 0 0 0 50 33V 19 10A 31 0C 51 0 25 5Ah 53 2V 25 0A 0 0 0 50 30V 16 90A 30 2C 12 0 6 0Ah 53 2V 25 0A 0 0 0 4 5 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V 0 0A 0 0 0 0 00V 0 00A 0 0C 0 0 0 0Ah 0 0V ...

Page 30: ...cable Generator Grid Backup Load On Grid Home Load Battery Solar CT AC cable DC cable Smart Load Mode II With Wind Turbine Mode III With Generator Mode IV With Smart Load 28 Grid Backup Load On Grid Home Load Battery Wind CT AC cable DC cable Controller Wind Turbine ...

Page 31: ...s the safety requirements and electromagnetic compatibility requirements Before leaving the factory the inverter undergoes several rigorous tests to ensure that the inverter can operate reliably If any of the fault messages listed in Table 6 1 appear on your inverter and the fault has not been removed after restarting please contact your local dealer or service center You need to have the followin...

Page 32: ...onnection of PV panels and inverter is firmly and correctly 2 Check whether the PE cable of inverter is connected to ground 3 Seek help from us if can not go back to normal state 1 Please wait for a while and check whether it is normal 2 If still same and turn off the DC switch and AC switch and wait for one minute and then turn on the DC AC switch 3 Seek help from us if can not go back to normal ...

Page 33: ...ed by insufficient ventilation of equipment Damage caused by failure to comply with applicable safety standards or regulations Damage caused by natural disasters or force majeure e g floods lightning overvoltage storms fires etc In addition normal wear or any other failure will not affect the basic operation of the product Any external scratches stains or natural mechanical wear does not represent...

Page 34: ...ower W PV Input Voltage V MPPT Range V Start up Voltage V PV Input Current A No of MPPT Trackers No of Strings per MPPT Tracker AC Output Data Rated AC Output and UPS Power W Peak Power off grid 4680W 6500W 11A 11A 2 1 1 370V 100V 500V 125 425V 150V 3600W 5000W 3960W 5500W Max AC Output Power W 2 times of rated power 10 S Full Load DC Voltage Range 240V 425V 32 Technical Data SUN 3 6K SG01 03LP1 E...

Page 35: ...utput Over Current Protection Integrated Integrated Integrated Integrated Integrated Integrated Power Factor 0 8 leading to 0 8 lagging Output Shorted Protection Output Over Voltage Protection Certifications and Standards Grid Regulation Safety Regulation EMC General Data Operating Temperature Range Cooling Noise dB Communication with BMS Weight kg Size Width Height Depth mm Protection Degree Inst...

Page 36: ...Add No 26 30 South Yongjiang Road Beilun 315806 Ningbo China Fax 86 0 574 8622 8852 Tel 86 0 574 8622 8957 E mail wutz deye com cn Web www deyeinverter com Ver 1 6 2020 04 ...