background image

Distributor of Desco: Excellent Integrated System Limited

Datasheet of 60480 - EMITTER BOARD O'HD IONIZER PAIR 
Contact us: [email protected] Website: www.integrated-circuit.com

 

 

Excellent Integrated System Limited

Excellent Integrated System Limited

Stocking Distributor

Stocking Distributor

Click to view price, real time Inventory, Delivery & Lifecycle Information:

Click to view price, real time Inventory, Delivery & Lifecycle Information:

Desco

Desco

60480

60480

 

 

 

 

For any questions, you can email us directly:

For any questions, you can email us directly:

[email protected]

[email protected]

                               1 / 9

                               1 / 9

Summary of Contents for 60478

Page 1: ... System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Desco Desco 60480 60480 For any questions you can email us directly For any questions you can email us directly sales integrated circuit com sales integrated circui...

Page 2: ...rated circuit com Website www integrated circuit com CRITICAL ENVIRONMENT C E SERIES OVERHEAD IONIZER OWNER S MANUAL DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 Fax 909 627 7449 DESCO EAST 90 Hudson Road Canton MA 02021 781 821 8370 Fax 781 575 0172 Web Site http www desco com TB 2087 3 02 Page 1 of 8 Made in America ...

Page 3: ...nization or other charge mitigating techniques shall be used at the workstation to neutralize electrostatic fields on all process essential insulators if the electrostatic field is considered a threat Ionization is used to neutralize charges on process necessary insulators and isolated semiconductors Some examples of process necessary insulators are the PC board itself plastic test stands plastic ...

Page 4: ...d be supported as well to provide protection against any hazard to the operator S hooks are provided with each unit to facilitate mounting using the chain suspension method The ideal mounting height is 24 above the work surface although the ionizer may be located slightly higher or lower if required For maximum performance care should be taken to insure that the intake grills for the fans are not ...

Page 5: ...wer may be opened when the cordset is removed In addition an IEC Outlet on the opposite end of the ionizer can supply power for a charged plate analyzer or for daisy chaining a second unit TB 2087 Page 4 of 8 Front Panel Display and Controls See figure 3 System Status is the information center on the front of the ionizer From it the operator can easily check the operational status of the ionizer P...

Page 6: ...y switch can be set to the LOCK position and normal workstation use resumed If the ionizer is used in a manner not specified by the manufacturer the protection provided by the ionizer may be impaired Maintenance As with all ionizers periodic maintenance will be needed to provide optimum performance Reference IEC 61340 5 2 1paragraph 5 2 9 The frequency of monitoring ionizers really depends on how ...

Page 7: ...s will often choose a much shorter interval especially if the product being worked on is very sensitive On very sensitive product we recommend checking the calibration any time an emitter cassette is removed and replaced Warning Do not attempt to calibrate this unit without proper equipment such as a charged plate analyzer Adjustments to the calibration controls should be performed by authorized t...

Page 8: ...old the BAL switch to find its most positive point use the BAL switch to find its most negative point calculate the midpoint and set the balance using the BAL buttons to that point Example if the most positive point is 40V and its most negative point is 10V you would set the balance to 15V TB 2087 Page 7 of 8 5 Adjust each fan s output by placing the charge analyzer plate underneath it and turning...

Page 9: ...LY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will Desco or any seller be responsible or liable for any ...

Reviews:

Related manuals for 60478