background image

 

 

STORM 415V SALT WATER 

 

STORM 415V SALT WATER CABINET 

 

HURRICANE D1 SALT WATER 

Declaration of Conformity 

(E.H.S.R) 

 

We, Demon International Limited of Abbots Close, Lee Mill Industrial Estate, Ivybridge, 
Devon, PL21 9GA Declare this machine must be operated in accordance with the  
operation and safety instructions as supplied with this machine. This machine is  
manufactured in accordance with the following standards. 
 
HSE PVB PM - BS415 Part 1 - BS5415 Section 2.4 1986 
 
This instruction manual is relevant only to the following machine and will not be kept 
updated  unless  specifically  requested  by  the  customer.  However  any  changes  to  the 
operating procedure or changes which might affect the safety of this machine will be 
notified to the registered owner of this machine only. 

Machine Type 

 

Serial Number 

 

Voltage 

 

Working Pressure 

 

Date of  Supply 

 

Operations Manual 

Demon Salt Water Range 

Summary of Contents for HURRICANE D1 SALT WATER

Page 1: ... This machine is manufactured in accordance with the following standards HSE PVB PM BS415 Part 1 BS5415 Section 2 4 1986 This instruction manual is relevant only to the following machine and will not be kept updated unless specifically requested by the customer However any changes to the operating procedure or changes which might affect the safety of this machine will be notified to the registered...

Page 2: ...ow rate 15lpm HP Nozzle 2504 Unloader VRSS Motor MTR00220 Voltage 415v Hurricane D1 Salt Water Engine Yanmar L100 Pump RK SS 15 20 Pressure 200 bar 2900psi Flow 15lpm HP Nozzle 2504 Gearbox 2 1 Reduction 1690 Unloader VRSS Pump Oil 10W 40 Gearbox Oil EP90 Technical Specifications ...

Page 3: ...SED OPERATION Check that electric motor is switched OFF a Plug into a suitable electrical source Not an extension lead b Turn on water supply c Ensure that the trigger is OPEN to vent air from the pump d Switch ON electric motor e Open regulator nozzle slightly and direct lance on surface to be cleaned Press operating trigger f Adjust pressure regulator as required to obtain working pressure g NOT...

Page 4: ...pressure to 500psi The chemical will now be automatically injected into the water c On completion of work flush through hose and gun with clean water to remove any residual detergent SERVICING The Storm range require little maintenance apart from checking the oil level at least every week and changing the oil should it turn white or it is six mouths old If the oil turns white it is due only to wat...

Page 5: ...and gloves take particular care with detergents and chemicals e NEVER attempt to disconnect any hose with pressure in it or allow the hose to be flattened or kinked f DO NOT use a high pressure hose from a ladder Use a platform tower or proper scaffold ing g CHECK that your supply voltage agrees with that shown on the machine h If an extension lead is used unwind all cable off the drum to stop ove...

Page 6: ...orrect setting Low pressure with noise and vibration Valves worn or blocked Piston seals worn Pump sucking air Clean replace as required Replace Check water supply pipe and un ions Pump will not by pass Non return valve dirty or jammed Clean or replace Water drips from pump box Pump seals worn Replace Oil drips from pump bottom Oil seal worn Replace Oil is milky in colour Water ingress through oil...

Page 7: ...Wheel400 Pump ARRK SS15 20 Unloader ARVRSS 9mtr Hose HH00030MVG Valve Kit ARKIT 2514 Oil Seal Kit ARKIT 2528 Piston Kit ARKIT 2515 Seal Kit ARKIT 2516 Storm Salt Water General Arrangement ...

Page 8: ...p ARRK SS15 20 Unloader ARVRSS Seal Kit ARKIT2516 Piston Kit ARKIT 2515 Valve Kit ARKIT2514 Oil Seal Kit ARKIT 2528 Wheel Wheel400 Support Rings ARKIT1829 Pressure Gauge DEM20620 9mtr hose HH00030MVG Hurricane D1 Salt Water General Arrangement ...

Page 9: ... items considered fair wear and tear Parts which may or may not wear out during the first year and which are considered service items which will need replacing from time to time High pressure nozzle lance trigger hoses fuel nozzle fuel filter piston seals valves unloader seats and seals water filter non return valve chemical barbs chemical pipes and pump oil seals It is the owners responsibility t...

Page 10: ... purchase order number to cover the parts When the parts are fitted they must be returned for examination before a credit note is issued 4 If you are unable to repair the machine then we will despatch an engineer to carry out the repair We will need a purchase order to cover the cost of transport to and from the site and for parts and labour if the repair is not covered under the warranty 5 If req...

Page 11: ...I can t get the pressure to where it used to be where do I start ...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...D T1 T2 T3 95 96 L N E TSS AUTO VALVE MOTOR See Storm cabinet switch diagram for wiring of switches The low water tank sensor wiring is in series with the TSS TSS sensor blue joined Brown on TSS to 96 Brown on low water sensor to switch Mains To Switch Bullet Join Bullet Join ...

Page 17: ...AIR SWITCH L3 L2 L1 96 95 T3 T2 T1 OVER LOAD A1 A2 MAINS SUPPLY AUTO SWITCH Storm 4 and Wall Mounted 415v Contactor KW 24 06 11 ...

Page 18: ...6 COLD WATER LANCES Pos Part No Description Qty 1 N26001 15045 Nozzle 1 2 MTM90040 Adjustable Nozzle 1 3 DEM10031B QR Lamce 1 4 DEM10030 QR Trigger 1 5 MTM70012 MVG Coupling 1 ...

Page 19: ...Hose Joiner MV00500 Alternative Hose Lengths 15 Metre HH00050MVG 30 Metre HH00100MVG High Pressure Hoses 1 2 3 4 1 Hose Insert MV00490 items 1 and 2 2 Nut 3 High Pressure Hose HH00030MVG 4 Hose Joiner MV00500 Alternative Hose Lengths 15 Metre HH00050MVG 30 Metre HH00100MVG ...

Page 20: ...ilter 3 MTM73001 QR Nipple Female 4 MTM73020 QR Nipple Male 5 HH0053 Yellow Hose 6 DEM20500 Jubilee Clip 7 DEM10042 INC 1 4 5 6 Suction filter with Hose and fittings 8 DEM10115 Detergent Pipe Chemical Pipe 3mtr 9 MTM73K991 Plastic washer for N0 3 1 2 5 6 6 3 4 8 9 Storm Range Inlet Fittings ...

Page 21: ...EEC The Machinery Directive and its amending directives 2000 14 EC Noise Directive Harmonised Standards Applied EN 292 1 EN292 2 now ISO 12100 EN 60335 2 79 EN55014 1 EN55014 2 EN 61000 3 2 Applied national standards and technical specifications DS EN 60335 2 79 Applied conformity evaluation method Appendix V Sound power level dB A HAV All triggers and lances have vibration levels below 2 5 m s s ...

Reviews: