Service, Installation and Care Manual

Please read this manual completely before attempting to install or operate this equipment!  Notify carrier of 

damage!  Inspect all components immediately.  See page 2.

Refrigerators and Freezers

Effective Date July 2005

IMPORTA

NT INFOR

MATION

READ BEF

ORE USE

PLEASE S

AVE THES

E INSTRU

CTIONS!

Summary of Contents for ColdPro F1FL

Page 1: ...ead this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerators and Freezers Effective Date July 2005 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...ted Delfield is a registered trademark of The Delfield Company CONTENTS SERIAL NUMBER INFORMATION Even though most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If d...

Page 3: ...1HL 115 60 1 9 18 7 14 04 1 2 2325 19 4 oz 334 LBS 5 15P 404A F2FH 115 60 1 10 40 25 28 08 3 4 3650 20 5 oz 558 LBS 5 15P 404A F2HH 115 60 1 10 40 25 28 08 3 4 3650 20 5 oz 558 LBS 5 15P 404A F3FH 115 60 1 16 61 8 42 12 1 4500 28 2 oz 766 LBS 5 20P 404A STORAGE SHELF SHIP NEMA REFRIG MODEL VOLTAGE AMPS CAPACITY FT 115 60 1 9 18 7 14 04 1 2 2325 19 4 oz 334 LBS 5 15P 404A 115 60 1 9 18 7 14 04 1 2 ...

Page 4: ...nnot circulate The refrigerated air is discharged at the top rear of the unit It is important to allow for proper air flow from the top rear to the bottom of the unit Obstructions to this air flow can cause evaporator coil freeze ups loss of temperature or overflow of water from the evaporator drain pan However bags and other items can still be located to the far rear of the cabinet Air is brought...

Page 5: ...trol setting at 6 Set toward 1 for warmer temperatures and toward 7 for colder temperatures Refrigeration cycle Refrigerators The evaporator fans will run continuously unless a door is open The door switch will activate the lights when opened and turn power off to the evaporator fan motors 1 The temperature control allows for the evaporator coil to clear after each off cycle and before the compres...

Page 6: ...ndenser fins must be cleaned of dust dirt and grease regularly It is recommended that this be done at least every three months If conditions are such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available condenser cleaner may be required Stainless Steel ...

Page 7: ... door is beginning to sag it may become necessary to tighten the screws that mount the hinge brackets to the frame of the unit If the doors are loose or sagging this can cause the hinge to pull out of the frame which may damage both the doors and the door hinges In some cases this can require qualified service agents or maintenance personnel Drain Maintenance Each unit has a drain located inside th...

Page 8: ...vice and Installation Manual For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com 8 WIRING DIAGRAMS REFRIGERATORS Models R1FR R1FL R1HR R1HL R2FH R2HH R3FH 115 VOLT 60 CYCLE 1 PHASE ...

Page 9: ...ColdPro Service and Installation Manual For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com 9 WIRING DIAGRAMS FREEZERS ...

Page 10: ...WITH HOT GAS LOOP X X 000 BXR 0032 CONDENSATE PAN ASSEMBLY WITH HOT GAS LOOP X X 127 BXV 0080 CONDENSATE PAN SLIDE X X X X 3516345 CONDENSER COIL X 3516346 CONDENSER COIL X 3516347 CONDENSER COIL X 3516348 CONDENSER COIL X 3516349 CONDENSER COIL X 3516350 CONDENSER COIL X 2162708 CONDENSER FAN MOTOR INCLUDES BLADE GUARD X 2162709 CONDENSER FAN MOTOR INCLUDES BLADE GUARD X X 2162710 CONDENSER FAN M...

Page 11: ...ORATOR COIL ASSY X 000 BXY 0035 EVAPORATOR COIL ASSY X 133 BXS 0030 EVAPORATOR COIL BOTTOM PANEL X 133 BXS 0031 EVAPORATOR COIL BOTTOM PANEL X 133 BXS 0032 EVAPORATOR COIL BOTTOM PANEL X 133 BXS 0033 EVAPORATOR COIL BOTTOM PANEL X 133 BXS 0034 EVAPORATOR COIL BOTTOM PANEL X 133 BXS 0035 EVAPORATOR COIL BOTTOM PANEL X 3516361 EVAPORATOR FAN GUARD X X X X X X 2162707 EVAPORATOR FAN MOTOR INCLUDES BL...

Page 12: ... POWER CORD 16GA X 129 BEJ 0030 REAR MACHINE COMPARTMENT COVER X X 129 BEJ 0031 REAR MACHINE COMPARTMENT COVER X X 129 BEJ 0032 REAR MACHINE COMPARTMENT COVER X X 3978195 SHELF X 3978207 SHELF X 3978198 SHELF LEFT X X 3978209 SHELF LEFT X X 3978206 SHELF MIDDLE X 3978208 SHELF MIDDLE X 3978199 SHELF RIGHT X X 3978210 SHELF RIGHT X X 3234859 SHELF PILASTER STRIP X X X X X X 9321587 THUMB SCREWS FOR...

Page 13: ...EW M4 16MM LONG STAINLESS STEEL M4 NUT STAINLESS STEEL REFRIGERATOR VINYL DRAIN TUBE 0 625 OD 0 5O ID FREEZER VINYL DRAIN TUBE 0 375 OD 0 25 ID PART NUMBER DESCRIPTION UNIT TYPE 1 DR REF 2 DR REF 3 DR REF 1 DR FRZ 2 DR FRZ 3 DR FRZ 123 BEI 0030 SUCTION LINE COVER X X X 123 BEI 0031 SUCTION LINE COVER X X X 3516338 THERMOMETER X X X X X X 9321593 THERMOMETER BULB CLIP X X X X X X 127 BXV 0040 THERM...

Page 14: ...ved with a Service Work Authorization from Delfield You must submit the number with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Thermostat Contactor Relay Door Jamb Switch Evaporator Condenser Fan Motor and Blade Hi limit Thermal Protector Switch Door Hinges Locks and Gaskets Fan Delay Defrost Termination Switch Condensate Element Compressor Start Components and Overload Protector Defr...

Page 15: ...CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued after the part has been received and in...

Page 16: ... This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting form any contingency beyon...

Page 17: ...ColdPro Service and Installation Manual For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com 17 NOTES ...

Page 18: ...ColdPro Service and Installation Manual For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com 18 NOTES ...

Page 19: ...ColdPro Service and Installation Manual For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com 19 NOTES ...

Page 20: ...ous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model ___________________S N _____________________________ Installation Date __________________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN ...