background image

USB-I/O Manual

UHR-32  -  DIN-Rail-Version

UPR-32  -  Board-Version

32 relay output channels

DECISION-COMPUTER  

 

Jürgen Merz e.K.

Lengericher Str. 21

49536 Lienen

T49 (0)5483-77002

T49 (0)5483-77003

http://www.decision-computer.de

Summary of Contents for UHR-32

Page 1: ...l UHR 32 DIN Rail Version UPR 32 Board Version 32 relay output channels DECISION COMPUTER Jürgen Merz e K Lengericher Str 21 49536 Lienen Telefon 49 0 5483 77002 Telefax 49 0 5483 77003 http www decision computer de ...

Page 2: ...age includes the following items USB 32R Board USB cable Software and Manual CD The DIN Rail version comes with a EMI Protection kit This kit is optional in the board version Operating temperature range 0 55C Relative humidity rage 0 90 Size 250 mm x 120 mm x 55 mm This device should not be used in applications where failure may result in death or injury without proper consideration and design of ...

Page 3: ...ucts must be 5V external DC It is to pay attention to correct polarity Otherwise the product could be damaged If the board is by wrong power supply except function you can try new store the firmware The U EMI 1 Kit is included with the DIN rail version and includes ferrite sleeve shielded by EMI for the power cable Are shown on the image above For earlier versions of the Decision USB IO was also t...

Page 4: ... board it can t work normally and sometimes it will cause device manager keeping refreshing itself or can t recognize the device To reset the hanging USB Module S1 Reset Button S2 USB ID Set different ID for each board Multiple Boards Connect 1 2 3 4 Card ID ON ON ON ON OFF ON ON ON 14 ON OFF ON ON 13 OFF OFF ON ON 12 ON ON OFF ON 11 OFF ON OFF ON 10 ON OFF OFF ON 9 OFF OFF OFF ON 8 ON ON ON OFF 7...

Page 5: ...Relay Ch 14 Output 14 NO 14 Relay Ch 14 Output 15 COM 15 Relay Ch 15 Output 16 NO 15 Relay Ch 15 Output Pin Signal Description 1 COM 16 Relay Ch 16 Output 2 NO16 Relay Ch 16 Output 3 COM 17 Relay Ch 17 Output 4 NO 17 Relay Ch 17 Output 5 COM 18 Relay Ch 18 Output 6 NO 18 Relay Ch 18 Output 7 COM 19 Relay Ch 19 Output 8 NO 19 Relay Ch 19 Output 9 COM 20 Relay Ch 20 Output 10 NO 20 Relay Ch 20 Outpu...

Page 6: ...s high as several hundred volts and becomes a major factor to deteriorate the contacts DC Protection circuit with a diode DC and AC Protection circuit with Varistor or RC element The suppressor must be made to the load Relay Out Contact protection circuits 1 The LED1 is an indicator to show the power is supplied normally 2 The LED2 is an indicator to warning the USB link status When it lights it m...

Page 7: ...Size ...

Page 8: ...er installation is required The functions for access and control of HID hid dll you can find in the Windows System32 folder 1 Power supply 5V connect 2 USB connect 3 USB input device device driver software is successfully installed 4 USB input device use now possible 5 In the Control Panel you can find the Decision USB module now 6 Ready to use Windows 7 8 installation example Installation ...

Page 9: ...s a standard COM port This function is only implemented in USBLABKIT Linux Support dcihid 0 5 1 Basic function library and demo program 2009 05 01 This package includes a c library and a demo program which is develo ped by Decision Computer to communicate with the USB Series Device under Linux It also includes a ReadMe file to demonstrate how to use it and package s format is tgz Firmware Update F...

Page 10: ...ad button to update firmware 6 Set Board Id between 0 14 and press Reset button and connect PC again The remote control of Decision USB products by LAN or wireless with a remote PC is very simple with a multi port USB Server Because no driver should be installed to the installation and programming is very easy Under Windows are the external USB I O directly in the Device Manager and can be connect...

Page 11: ...APPENDIX B DATA SHEET ...

Page 12: ......

Page 13: ...ts in materials and workmanship and be fully functional under normal usage In the event of the failure of a SmartLab product within the specified warranty period SmartLab will at its option replace or repair the item at no additional charge This limited warranty does not cover damage resulting from incorrect use electrical interference accident or modification of the product All goods returned for...

Page 14: ......