www.smartlockdigital.com
1.
Enter “Zero” six times
DUAL CODE
2.
Enter your existing six (6) digit code once
Two combinations required to open
3.
Enter your NEW six (6) digit code two times
TI ME DELAY
4.
If a mistake is made wait thirty (30) seconds and repeat steps 1-3
Delay period 1-99 minutes
5.
test lock operation several times before closing the door
Open period 1-19 minutes
39E ComboGard Pro
4300M swingbolt/ 6040M squarebolt/ 6034 springbolt instructions
Operating Guide
_
Factory default code is open on ‘1’ (see keypad only setup instructions before operating lock)
Opening the Lock
1.
Enter valid six (6) digit combination. The lock will emit a double beep if
valid code has been entered.
2. Within 3.5 seconds of entering the valid code the lock can be opened-
either turn the keypad or handle (depending on how the lock has been
installed. Please ask your installer for further details)
3.
Pull door open.
INVALID CODE ENTRY
– Triple beep after six (6) digits are entered
VALID CODE ENTRY
- double beep after six (6) digits are entered
Opening the Lock with Time delay
(feature must be pre-enabled)
1.
Enter valid six (6) digit combination. Delay period starts. LED flashes
RED at one (1) second intervals
2.
At end of delay period open period starts. LED flashes RED at ½ second
intervals. During open period enter valid code to open
1.
If valid code entered during delay, delay restarts
2.
If invalid code entered during delay, delay aborts
3.
If invalid code entered during open period, open period continues
Dual Combination Operation
(feature must be pre-enabled)
1.
Second user must be added in setup stage of lock and dual mode
turned on. Second user cannot then be disabled or removed.
2.
If time delay is active, one valid code will start the delay period. Both
codes must then be entered to open the lock during the open period
3.
To open, enter both codes, one after the other
Time Delay Override Operation
(feature must be pre-enabled)
1.
User 9 must be added in setup stage of lock and TDO mode turned
on, User 9 cannot then be disabled or removed
2.
Entry of override code during Delay period will open the lock
3.
Entry of override code at any time will immediately open the lock
Silent Signal Alarm
(feature must be pre-enabled, duress interface required)
1.
Enter code as normal but enter the last digit one number HIGHER or
LOWER
EXAMPLE: code = 123456. Duress code is 123455 or 123457
The lock will open without any indication duress has been sent.
Changing your code
Always perform operation with the door open
If lock is enabled for dual code each code must be changed
independently
STANDARD
FEATURES
WRONG TRY
PENALTY
Four (4) consecutive invalid codes initiates
five minute delay period.
LOW BATTERY WARNING
Repeated audio and visual signal (LED
flashing and repeated beeping) during
opening indicates battery low.
AUDIO AND VISUAL SIGNAL
Double signal (LED flashes and unit beeps)
indicates entry is valid or accepted.
Triple signal indicates invalid or not
accepted.
PROGRAMMABLE FEATURES
ACTIVE
MANAGER CODE
Add/remove second user
Enable/disable second user
USER CODE
Open lock
Change Code
TIME DELAY OVERRIDE
VALID CODE ENTRY
- double beep after valid six (6) digits are entered
INVALID CODE ENTRY
– Triple beep after six (6) digits are entered and
old code is still valid
SILENT SIGNAL ALARM
Duress signal if last number of code (s) is
entered using one number higher or one
number lower
DISABLE LOCK
Input signal disables opening of lock by
valid code
Smartlock Digital – a division of Davcor Pty Ltd ABN 95 003 562 598 PH +61-2 9612 4774 Fax +61-2 9612 5774 email [email protected]