background image

User’s manual
FLIR Ex series

dataTec AG

E-Mail: [email protected]

>>> www.datatec.eu

Ihr Ansprechpartner / 
Your Partner:

Summary of Contents for FLIR E5-XT

Page 1: ...User s manual FLIR Ex series dataTec AG E Mail info datatec eu www datatec eu Ihr Ansprechpartner Your Partner...

Page 2: ...tos megjegyz s Az eszk z haszn lata el tt figyelmesen olvassa el s tartsa be az sszes utas t st figyelmeztet st vint zked st s jogi nyilatkozatot Nota importante Prima di utilizzare il dispositivo imp...

Page 3: ...11 6 2 Battery 11 6 2 1 Install the battery 11 6 2 2 Remove the battery 11 6 3 Battery charging 11 6 3 1 Charge the battery using the battery charger 11 6 3 2 Charge the battery in the camera using th...

Page 4: ...saved image 25 9 6 Zoom 25 10 Gallery image archive 26 10 1 Open the Gallery 26 10 2 Open image files 26 10 3 Add a folder 26 10 4 Rename a folder 26 10 5 Change the active folder 26 10 6 Move files...

Page 5: ...15 Updating the camera 35 15 1 Update the camera Over The Air OTA 35 15 2 Update via USB cable with the FLIR Camera Updater 35 15 2 1 Install the FLIR Camera Updater 35 15 2 2 Connect the camera 35 1...

Page 6: ...ith Part 15 of the FCC Rules and with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this dev...

Page 7: ...ge the battery in temperatures between 10 C and 45 C 50 F and 113 F When the power supply AC adapter is used the battery must not be charged at an ambient tem perature above 35 C 95 F Do not attach th...

Page 8: ...nformation 1 1 4 Declaration of conformity The full text of the Declaration of conformity is available at the following internet address https support flir com resources 2758 T810624 r AF 93316 93316...

Page 9: ...e To access the FLIR Ex series user manual and other product documentation go to https support flir com resources 2758 To access the manuals for our other products as well as manuals for our discontin...

Page 10: ...d images for storage online To enable up load of images you need to connect the camera to the internet and pair the camera with a FLIR Ignite account Use a computer or other device with internet acces...

Page 11: ...camera 2 Infrared lens 3 Trigger to save an image 4 Camera lamp 5 Lever to open and close the lens cap 6 Battery 4 2 View from the rear 1 Touch screen 2 Archive button 3 Navigation pad 4 Back button...

Page 12: ...t 1 USB port 4 4 Serial number A label with the serial number is visible when the battery is removed The serial number is available in the camera settings Select Settings Device settings Camera inform...

Page 13: ...icons and indicators 3 Spotmeter 4 Temperature scale 5 Menu button 5 1 2 Status icons and indicators Battery level Green above 75 Yellow up to 75 Red up to 25 No color below 15 The available storage...

Page 14: ...do one of the following Tap the menu button at the bottom of the screen Push the center of the navigation pad To navigate the toolbars menus and dialog boxes and to change values in dialog boxes push...

Page 15: ...11 4 Pair with FLIR Ignite 9 Storage status of the FLIR Ignite account 5 3 1 Navigation To display the Quick menu swipe down from the top of the screen To navigate the Quick menu by using the touch sc...

Page 16: ...ble to easily disconnect the power supply Note It is good practice to disconnect the power supply from the mains socket when not in use 6 3 1 Charge the battery using the battery charger 1 Put the bat...

Page 17: ...in live mode push the On Off button This puts the camera in standby mode You can also set up the camera to enter standby mode after a period of inactivity Select Settings Device settings Auto power o...

Page 18: ...lamp You control the camera lamp on the Quick menu see section 5 3 Quick menu 6 8 Streaming The camera can stream what is currently visible on its screen to a computer via USB just as a connected web...

Page 19: ...s stored when an image is saved This means that you can edit the image later in the camera image gallery or in a FLIR Thermography software and select any of the image modes For the Digital camera ima...

Page 20: ...distance in the upper right corner 2 Tap the distance box This displays a slider 3 Tap the slider or push the navigation pad up down to adjust the distance 7 3 Move and resize the infrared image fram...

Page 21: ...ry accurate results wait 5 minutes after you have started the camera before measuring a temperature 8 2 Measurement tools To measure a temperature you can use different measurement tools e g a spot or...

Page 22: ...ool Select Center to center the box on the screen 4 To exit edit mode do one of the following Push the navigation pad and select Done Tap the screen outside the tool 8 2 4 Difference calculations delt...

Page 23: ...Settings Camera temperature range This dis plays a menu where you can select the temperature range 8 4 Thermal image adjustment 8 4 1 General Thermal image adjustment or thermal tuning means adjustin...

Page 24: ...changed to values close to the temperature of the isolator Automatic Manual 8 4 2 Change mode To change the image adjustment mode select Temperature scale on the main toolbar Then select Auto or Manu...

Page 25: ...for the relevant temperatures you will get more de tails in your area of interest 8 4 3 2 Lock touch screen When you have adjusted the image to levels that allow you to study your area of interest you...

Page 26: ...ad up down to increase decrease the level 3 Push the navigation pad left right to increase decrease the span 8 5 Color palettes The camera supports a number of different color palettes Frequently used...

Page 27: ...etting is locked and white when unlocked 8 7 Measurement parameters For accurate temperature measurements it is important to use appropriate measure ment parameters Emissivity The emissivity determine...

Page 28: ...easurement parameter you want to change 3 Select the appropriate parameter setting 8 7 2 Recommended values If you are unsure about the measurement parameter values the following are recommended Emiss...

Page 29: ...t options Reset image counter This displays a dialog box where you can select to re set the counter Note To prevent image files being overwritten the new counter value will be based on the highest exi...

Page 30: ...xit edit mode Change the measurement parameters Change the image mode Add a measurement tool Change the color palette or set a color alarm Save and exit edit mode 7 To get the edited image stored onli...

Page 31: ...the navigation pad left right or swipe left right on the screen 4 To display the top toolbar push the navigation pad or tap the screen 5 To switch between the thermal image and visual image select on...

Page 32: ...lete files and folders 10 8 1 Delete folders 1 Go to the top level in the Gallery 2 On the top toolbar select 3 Select the folders you want to delete 4 On the right toolbar select This displays a dial...

Page 33: ...es To delete all files from the camera memory select Settings Save options storage Delete all saved files This displays a dialog box where you can select to permanently delete all saved files in the c...

Page 34: ...e account 11 2 Create FLIR Ignite account To create a FLIR Ignite account go to https ignite flir com and click Sign up 11 3 Connect camera to internet You can connect the camera to the internet via W...

Page 35: ...he screen to display the top toolbar 3 On the top toolbar select 4 On the right toolbar select 11 6 2 Upload multiple files 1 Go to a folder in the Gallery 2 On the top toolbar select 3 Select the fil...

Page 36: ...existence They appear in the list as Untitled To connect to such a network you will be prompted to enter additional parameters To enable disable the camera firewall select Settings Connections Advance...

Page 37: ...h Advanced settings for firewall trusted applications and streaming authentication 13 4 Camera temperature range The camera is calibrated for different temperature ranges The available temperature ran...

Page 38: ...sing the navigation pad Color theme Select light or dark theme for the user interface Reset options Reset default camera mode This will affect the image mode color palette meas urement tools and measu...

Page 39: ...yl alcohol 96 ethyl alcohol C2H5OH Equipment Cotton wool CAUTION If you use a lens cleaning cloth it must be dry Do not use a lens cleaning cloth with the liquids that are listed above These liquids c...

Page 40: ...allation 6 When the installation is completed the camera will automatically restart 15 2 Update via USB cable with the FLIR Camera Updater The FLIR Camera Updater is a Windows application used to upda...

Page 41: ...be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recy cling More information is available from the relevant local authority 16 1 Battery removal Befor...

Page 42: ...r interface of the product 17 6 Usage statistics FLIR Systems reserves the right to gather anonymous usage statistics to help maintain and improve the quality of our software and services 17 7 Copyrig...

Page 43: ...ems Inc All rights reserved worldwide Disclaimer Specifications subject to change without further notice Models and accessories subject to regional market considerations License procedures may apply P...

Reviews: