Page 2: ...rposes only and may be trademarks or registered trademarks of their respective owners Datalogic reserves the right to make modifications and improvements without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material 2008 Datalogic Mobile S r l All rights re...

Page 3: ...l Description 1 1 3 Package Contents 2 1 4 Accessories 2 2 CONNECTIONS 3 2 1 USB Connection 3 2 2 WLAN Connection 4 2 3 WPAN Connections 6 3 USE AND FUNCTIONING 7 3 1 Startup 7 3 1 1 Using the Stylus available only on Joya TM 8 3 2 Data Capture 9 3 2 1 Laser Data Capture 9 3 3 Description of the Keys 10 3 3 1 Resetting the Joya 11 3 4 Status Indicators 12 3 4 1 Taskbar 12 3 5 Data Capture Configur...

Page 4: ...rts 48 5 3 3 Internal Cabinet Space and Openings 49 5 3 4 Anchoring and Maintenance Issues 49 5 3 5 Power Supply Positioning and Cooling 49 5 3 6 AC Power Cabling 50 5 3 7 Wiring 51 5 3 8 Cable to Power Supply Connection 52 5 3 9 Affixing Cables to Cabinet 53 5 3 10 Safety Precautions 53 5 3 11 Connection to AC Line Voltage 54 5 4 Joya TM cradle dispenser firmware 55 5 4 1 APC installation 55 5 4 ...

Page 5: ...ement Customer shall have no right and Customer specifically agrees not to i transfer assign or sublicense its license rights to any other person or use the Software on unauthorized or secondhand Datalogic equipment and any such attempted transfer assignment or sublicense shall be void ii correct errors to or otherwise modify or adapt the Software or create derivative works based upon the Software...

Page 6: ...formance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of Java technology could lead directly to death personal injury or severe physical or environmental damage Microsoft Inc has contractually obligated Datalogic to make this disclaimer 7 Disclaimer of Warranties ...

Page 7: ...a refer to Datalogic Joya mobile computer You refers to the System Administrator or Technical Support person using this manual to install configure operate maintain or troubleshoot a Datalogic Joya mobile computer Cradle refers to Datalogic Joya Cradle Dispenser REFERENCE DOCUMENTATION For further information regarding Datalogic Joya refer to the SDK Help on Line ...

Page 8: ...he operative life of the Datalogic Joya mobile computer disposal must be performed in compliance with the laws in force Before using the device and the battery pack see par 4 2 and read every warnings about the device and the battery pack Do not submerge the Datalogic Joya in liquid products The Datalogic Joya is designed and labelled to be compliant with laws rules and regulations in force in the...

Page 9: ... visible al ojo humano y es emitida por la ventana indicada en la figura I D F E LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA DI USCITA 2mW LUNGHEZZA D ONDA EMESSA 650nm CONFORME A EN 60825 1 2001 LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG 2mW WELLENLÄNGE 650nm ENTSPR EN 60825 1 2001 RAYON LASER EVITER DE REGARDER...

Page 10: ... known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc CAUTION Use of optical systems with the scanner will increase eye hazard Optical instruments include binoculars microscopes eye glasses and magnifying glasses ITALIANO Le seguenti...

Page 11: ... Behörden auferlegt wurden und sie beziehen sich auf den korrekten Gebrauch vom Terminal NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825 1 2001 und CDRH 21 CFR 1040 Subchapter J Normen für die Lasersicherheit Es ist nicht notwendig das Gerät wegen Betrieb oder Installations und Wartungs Arbeiten zu öffnen CAUTION Unter keinen Umständen darf versuch...

Page 12: ... d ouvrir ou de réparer les composants de la cavité optique L ouverture de la cavité optique ou la réparation de ses composants par une personne non qualifiée peut entraîner le nonrespect des règles de sécurité relatives au laser Le système optique ne peut être réparé qu en usine ATTENTION L utilisation de procédures ou réglages différents de ceux donnés ici peut entraîner une dangereuse expositio...

Page 13: ...lamente ATENCIÓN La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligrosa a la luz láser visible El aparato utiliza un diodo láser a baja potencia No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duración Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente ...

Page 14: ...verificare eventuali restrizioni o licenze Ulteriori informazioni sono disponibili sul sito http europa eu int comm enterprise rtte spectr htm FRANÇAIS Contactez l autorité compétente en la gestion des appareils à radio fréquence de votre pays pour vérifier d éventuelles restrictions ou licences Pour tout renseignement vous pouvez vous adresser au site web http europa eu int comm enterprise rtte s...

Page 15: ...harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the re...

Page 16: ... the device at the opposite side of the pacemaker and or any other medical device Should turn this device OFF or move it immediately AWAY if there is any reason to suspect that interference is taking place Should ALWAYS read pacemaker or any other medical device guides or should consult the manufacturer of the medical device to determine if it is adequately shielded from external RF energy In case...

Page 17: ... is improperly installed and the air bag inflates serious injury could result WARNING Turn off the device when in any area with a potentially explosive atmosphere Observe restrictions and follow closely any laws regulations warnings and best practices on the use of radio equipment near fuel storage areas or distribution fuel areas chemical plants or where some operation involves use of explosive m...

Page 18: ...ine di ottenere un importante risparmio di energia e di risorse Per maggiori dettagli sulle modalità di smaltimento contattare il Fornitore dal quale è stata acquistata l apparecchiatura o consultare la sezione dedicata sul sito www mobile datalogic com Information for the user in accordance with the European Commission Directive 2002 96 EC At the end of its useful life the product marked with the...

Page 19: ...os urbanos Eliminar este producto de accuerdo con la Directiva permite de evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas de una eliminación inadecuada recuperar los materiales obteniendo así un ahorro importante de energía y recursos Para obtener una información más detallada sobre la eliminación por favor póngase en contacto con el proveedor donde lo compró o ...

Page 20: ...xx GENERAL VIEW A Display D Bumper G Loudspeaker B 6 keys keyboard E Cold reset Hole H Micro USB C TTL Serial connector F Neck Strip Anchor I Laser window Remove protective film cover before use ...

Page 21: ...xxi ...

Page 22: ......

Page 23: ... system and it was developed to meet the most demanding customer needs A huge quantity of on board memory is available it enables the user to adapt the terminal for any specific need Thanks to its great ergonomics and the state of the art architecture the Datalogic Joya is the right answer to enhance your business opportunities 1 2 MODEL DESCRIPTION The brand new Datalogic Joya is available in two...

Page 24: ...ly charged Therefore the initial operation to perform is to charge them 1 4 ACCESSORIES Cradle 912201000 Datalogic Joya Cradle Dispenser Batteries 91ACC1055 Datalogic Joya Battery Pack 10 pcs Cradle Accessories 91ACC1000 Power Supply 12V 300W 91ACC0730 Power Junction Cable I90x 3 Cradle 8 pcs 91ACC0650 Term Unlock Magnets 5 pcs Various 94ACC1328 Datalogic Joya Stylus Pens 10 pcs 91ACC1056 Datalogi...

Page 25: ...CONNECTION You can use any standard micro USB cable to directly connect the Datalogic Joya to a host computer to transfer data through the USB interface Key A Host Computer C Datalogic Joya B Standard Micro USB cable type USB A micro USB B ...

Page 26: ...rd radio frequency component and an Access Point connected to the host computer To launch this utility you can tap the specific icon if it s visible on the taskbar or you can open Connections folder or Control Panel from desktop and select the Summit Client Utility icon A Key A Datalogic Joya B Access Point C Host Application Server ...

Page 27: ...io and drops the radio connection When the terminal resumes depending on the radio power mode and security protocol selected it may take up to 30 seconds for the 802 11b g radio driver to re associate the radio to the network NOTE Area coverage and radio performance may vary due to environmental conditions access points types or interference caused by other devices microwave ovens radio transmitte...

Page 28: ...luetooth working the module must be powered on using the Wireless Communications applet see par 3 6 3 and perform the Discovery procedure see par 3 7 2 NOTE Suspending the terminal powers off the Bluetooth radio and drops the piconet Bluetooth connection When the terminal resumes it takes approximately 10 seconds for the Bluetooth radio driver to re initialize the radio NOTE Area coverage and Blue...

Page 29: ...oon as the mobile computer is on the Windows CE 5 0 desktop configuration will appear on the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure The mobile computer goes into power off low power with display and keyboard backlight off when it is no longer used for more than a programmable timeout which is defined in the POWER applet of...

Page 30: ...em On the pop up menu that appears tap the action you want to perform To recalibrate the touch screen use the Stylus Applet CAUTION Use only original Datalogic styluses supplied with the product itself In harsh applications use of screen protectors should be taken into consideration in order to extend the touch screen operating life To prevent damage to the screen do not use sharp devices or any d...

Page 31: ...re and enable data capture parameters refer to par 3 5 3 2 1 Laser Data Capture To scan barcodes point the Datalogic Joya laser model onto the code from a distance within the reading range while pressing the Up key The lighted band emitted by the laser must completely intercept the barcode as shown in the figure below If enabled the emission of an acoustic signal will indicate that the scan has ta...

Page 32: ...eyboard The following image shows this keyboard Main Keys Function Key it corresponds to ArrowUp Key Key it corresponds to ArrowDown Key Key Left it corresponds to F1 Function1 Key Key Right it corresponds to F2 Function2 Key Key it corresponds to ESC Key Key e it corresponds to ENTER Key ...

Page 33: ... in which all applications are forcibly closed and RAM is completely cleared Registry is restored from persistent memory if a saved copy is available see 3 6 1 and RAM file system completely erased You will lose any applications and data registry too which are not stored in persistent flash memory A cold boot is necessary when the Windows CE operating system locks up and the warm boot command does...

Page 34: ...ery is charging Keyboard Status Icons It indicates that the blue FUNC key has been pressed and is going to affect the next key press It indicates that the yellow FUNC key has been pressed and is going to affect the next key press It indicates that the ALPHA key has enabled the selection of the characters printed in orange It indicates the NUMERIC key selection the ALPHA key has not been pressed It...

Page 35: ...Emulation 3 5 1 Configure The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure The available barcode parameters are divided into two groups Reader Parameters and Scan Parameters The Reader Parameters depend on the type of scanner module installed on the mobile computer and allow barcode configuration i e enable disable Code 39 check digit co...

Page 36: ...ctly on the item field or from the menu To change a value for example select the line of the value to be changed choose Edit from the Parameter Menu then choose a new value from the values listed in the box see following figures Selecting Data Capture Setup Parameters Alternatively using the stylus you can tap once directly on the value on the right column continue tapping until the desired value ...

Page 37: ...t this value to 0 BeepFrequency determines the frequency in Hertz of the beeper GoodReadSound is the beep sound emitted when the scanner reads a code LedDuration the length of the good read led pulse in milliseconds LedPulses the number of times the good read led pulse is emitted when the scanner reads a code ContinuousMode disables the effect of the ScanTimeout parameter KeyboardEmulation if enab...

Page 38: ...BeepDuration 20 BeepFrequency 2000 GoodReadSound Beep LedDuration 200 ms LedPulses 1 ContinuousMode Disabled KeyboardEmulation Enabled SoftTrigger Enabled ScanAlwaysOn Disabled NotPrintableChar Leave ScanButton Enabled BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS LASER MODELS UPC A Enabled UPC E Enabled EAN 8 Enabled EAN 13 Enabled Code 39 Enabled Code 39 Full ASCII Disabled Code 32 Disabled 2 5 I...

Page 39: ...et Capture enables code reading Data Capture Window Data Capture can also be enabled through the Configuration applet by selecting File Scanner from the main menu or by enabling the parameter Scan Always On in the Scan Parameters branch Enabling the Data Capture ...

Page 40: ... double tapping the Registry Admin icon The Registry Administration Main window appears Two functions are available Save Registry allows permanently saving the Windows configuration example custom configuration of screen desktop background color or network adapter configuration to non volatile memory SAVE button Restore Default Registry allows restoring the initial factory default configuration Re...

Page 41: ...USE AND FUNCTIONING 19 3 Registry Administration Window ...

Page 42: ...es belonging to the FLASH image These current working session files will be backed up in the Backup Windows directory At the next cold boot the files previously saved in the Backup Windows directory will be restored to the Windows directory see par 3 8 Safe Setup with this button the installation of software programs will be saved to non volatile memory Backup directory Before doing this it will b...

Page 43: ... At the next cold boot these files will be restored see par 3 8 Simply skip the first mask either by closing it or by pressing the ESC key When it closes a new mask will pop up it will enable any type of installation even remote ones like ActiveSync installations Make sure the installation directory is Windows or one of its sub directories After installation tap OK Safe Setup will save the new fil...

Page 44: ...IRELESS COMMUNICATIONS applet provides management of the 802 11 b g radio and of the Bluetooth module Select the WIRELESS COMMUNICATIONS applet by double tapping the Wireless Communications icon The following window will appear Wireless Communications Window ...

Page 45: ...o configuration and site survey purposes Summit Radio Card Starting client The client can be started from the Windows CE desktop by clicking the related icon of the tool bar at the bottom Fig 1 Summit client utility Summit Radio Card Main screen The following picture shows the screen when Summit Client is started Fig 2 Client utility main ...

Page 46: ...ard is managed through radio profiles Fig 3 Profile manager User can rename delete create and save any changes by the Rename Delete New and Commit buttons The name chosen for the profile is his own identifier Profile is defined by a set of parameter that user can customize The following is a simple profile for testing Field Value SSID tsunami Client Name D08P00088 the Joya S N Power Save Fast Tx P...

Page 47: ...g 4 Status screen User can read current profile name client device name IP address and MAC address The Access Point to which the terminal is currently associated t is specified by name IP address and MAC address User can also read the signal strength dBm the transmission power mW the WiFi channel the rate Mbps and the signal quality ...

Page 48: ...s Fig 5 Diagnostic screen The Re connect button disables and re connects radio card The Release Renew button releases and renews the radio interface IP address In order to test the radio link user can ping the associated access point by pressing the Start Ping button Fig 6 Start Ping Fig 7 Stop Ping The ping output is displayed on the large text windows ...

Page 49: ...le profiles Site Survey functionality is not available Summit Radio Card Global Settings screen There are many other parameters used to configure the radio card and they do not depend on used profile nevertheless for good working it s recommended do not change the default values Fig 8 Global screen ...

Page 50: ...own in Figure 1 2 Adjust Double Tap sensitivity if needed or desired 3 Select the Calibration tab to open the Calibration application Figure 1 4 Tap Recalibrate to open the Calibration screen shown in Figure 2 5 Carefully press and briefly hold stylus on the center of the target Repeat as the target moves around the screen Press the ESC key to cancel the stylus calibration 6 Press the ENTER key or...

Page 51: ... screen comes up if valid calibration settings are not available This happens in the following circumstances 1 At the first startup of the terminal 2 After restoring registry default settings using the applet Registry Admin and performing a warm boot 3 After a Clean Boot 4 After a Firmware Update see par 3 9 ...

Page 52: ...tion to your Datalogic Joya through the following electrical interfaces USB directly Bluetooth see par 3 7 2 It is possible to constantly synchronize while connected to a desktop computer or alternatively synchronization can be performed only when the synchronize command is chosen You can select which information types are synchronized and control how much data is synchronized NOTE By default Acti...

Page 53: ...iveSync Remote NOTE Microsoft ActiveSync Remote is no longer supported in Windows CE For backward compatibility you can download it from the Internet We suggest enabling the FTP Server and connecting to an FTP Client See par 3 7 3 ...

Page 54: ...n the Bluetooth Manager Device window 3 Tap on the Me button to enter the related window then tap on the ON button to activate the Bluetooth module The module activation may be also performed by using the WIRELESS COMMUNICATION applet as described in par 3 6 3 By tapping on the HW Details and SW Details buttons information about the mobile computer Bluetooth hardware and software will be displayed...

Page 55: ...the desired Bluetooth device has been selected tap on the Connection Wizard button to enter the related window where selecting the connection type to be used for communication with the Bluetooth device The Serial Port button starts communication through the Bluetooth serial port COM 5 typically used for connection with GPS devices The Printer button starts communication with a printer through the ...

Page 56: ...TALOGIC JOYA 34 1 3 6 Hide the Bluetooth Manager Device window by tapping on the icon available on each window or close it through the Close button available in the Me window see step 3 of this procedure ...

Page 57: ...GEDIT4 HKEY_LOCAL_MACHINE Comm FTPD DefaultDir AllowAnonymousUpload dword 00000001 UseAuthentication dword 00000000 BaseDir IsEnabled dword 00000001 LogSize dword 00001000 DebugOutputMask dword 00000017 DebugOutputChannels dword 00000002 IdleTimeout dword 0000012c AllowAnonymous dword 00000001 AllowAnonymousVroots dword 00000001 2 Copy this file to the Datalogic Joya using ActiveSync 3 Launch the ...

Page 58: ...he next cold boot before activating the shell Windows CE 5 0 will copy the contents including all sub directories of Backup Windows to Windows Likewise to maintain files that must be run at Windows CE 5 0 startup i e exe lnk vb htm etc it is necessary to copy them to the directory Backup Startup This directory does not exist originally only Backup exists and therefore it must be created The applic...

Page 59: ...re starting the update process This prevents the terminal from turning off while running and avoids a corruption of flash content CAUTION After the update process all the data stored in the backup folder could be irreparably lost as well as the device configuration even that one stored in persistent memory Therefore before starting a firmware update it is advisable to run a backup copy of the data...

Page 60: ...o continue NO to cancel operations 5 DLUpdater detects whether an external power source is present If not a warning will come up on the screen asking for a confirmation before carrying on see figure 2 Figure 1 Figure 2 7 DLUpdater performs all the necessary operations of check update and verify and if no errors occur during the update terminates the running invoking a cold boot of the terminal so ...

Page 61: ...E AND FUNCTIONING 39 3 the data stored in the backup folder will be irreparably lost It is therefore recommended to run a backup of the data you want to preserve before starting a firmware update Figure 3 ...

Page 62: ...is possible by USB Direct connection with the host computer but with longer charging times and in this case it is advised to keep the mobile computer off NOTE The battery pack autonomy varies according to many factors such as the frequency of barcode scanning RF usage battery life storage environmental conditions etc CAUTION If the battery pack is new or has not been recharged for a long time it i...

Page 63: ...MAINTENANCE 41 4 4 2 REPLACING THE BATTERY PACK To correctly replace the battery pack proceed as follows 1 Unscrew the two screws placed on the back bottom The battery pack cover is now released ...

Page 64: ... the connector 3 Install the new battery pack first insert the connector respecting the right way then the upper side finally the bottom side leaving the plastic strip available for future replace 4 For correct locking first insert the upper part of the battery cover then the lower and rotate the screws to the horizontal position ...

Page 65: ...ebris and combustible materials or chemicals Do not use the battery pack of this terminal for power devices different from this mobile computer Immediately discontinue use of the battery pack if while using charging or storing the battery pack the battery pack emits an unusual smell feels hot changes colour or shape or appears abnormal in any other way Do not short circuit the battery pack contact...

Page 66: ...d in any part Battery pack usage by children should be supervised Collect and recycle waste batteries separately from the device in comply with European Directive 2006 66 EC 2002 95 EC 2002 96 EC and subsequent modifications US and China regulatory and others laws and regulations about environment NOTE In order to guarantee an adequate operating autonomy when replacing the battery pack the mobile ...

Page 67: ...e Joya slots each equipped with its own control unit an electromechanical system for blocking releasing the terminal notification light battery power and recharging circuits Its special structure makes it possible to design any type of dispenser wall mounted or island easily allowing twice the number of terminals to be installed per vertical square meter with respect to the competing systems 5 2 A...

Page 68: ...he figure below represents an 8 Joya Cradle Dispenser Base Unit organized in a single column Joya will be inserted into the Cradle Dispensers are at a minimum height of approximately 40 cm from the floor and a maximum height of about 160 cm from the floor ...

Page 69: ...Joya Cradle Dispensers are indicated The zoom of the upper edge of the supporting crosspiece indicates the necessity of reducing the radius of this edge as much as possible in order to provide a stable contact surface for the upper cover of the Joya Cradle Dispenser The power supply shelf is positioned so that it guarantees a sufficient volume of air flow for the cooling of the power supplies ...

Page 70: ...ted inside the Base Unit from crosspieces fixed to the side panels of the cabinet The front part of each Joya Cradle Dispenser cover rests on the upper edge of its supporting crosspiece while the back part rests on two fixing blocks attached to the crosspiece above it Joya Cradle Dispenser is mounted to the cabinet using two screws that are inserted into the holes provided towards the back of its ...

Page 71: ...antee full stability Suggestion It is preferable for the cabinet to have a removable back panel for easy access inside when performing cabling The top of the cabinet should also be removable for access to the power supplies during maintenance without the necessity of removing the cabinet from the anchoring points to the wall For this reason the power supplies should also be able to be mounted and ...

Page 72: ...ich could impede correct cooling If the power supplies are mounted using angular brackets use the threaded holes provided on the power supply case Make sure that the mounting screws are size M4 and do not penetrate the power supply case by more than 5 5 mm 5 3 6 AC Power Cabling Connection of the Power Supply to the AC line must be made using a cable having characteristics that meet the Safety Nor...

Page 73: ...Dispenser 3 2 1 BLUE Connector AMP 1 480700 0 Contacts AMP 350536 1 Series UNIVERSAL MATE N LOCK Ferrite RICHCO RRH120 056 300 Cable flexible flameproof 3 wire stranded individual wire diameter 1 mm 300 mm 40 mm BROWN YELLOW GREEN 3 2 1 Key To connect the Joya Cradle Dispensers to the power supplies the pre wired junction cables must be connected to three multi strand copper wires singly or incorp...

Page 74: ... two groups of three conductors are connected to the output terminals of the power supplies in the case of two power supplies one group of wires is connected to one power supply and the other group is connected to the other power supply in the case of a single power supply both groups of wires are connected to the same power supply Each three conductor cable group must be used to connect four of t...

Page 75: ... objects which may accidentally fall through the Cradle Dispenser into the inside of the cabinet Next image shows an example of affixing the Cradle Dispenser cables to the cabinet The Cradle Dispenser cables are connected to the main power cables through IDC connectors 5 3 10 Safety Precautions Joya Cradle Dispenser Cabinet the relative electrical wiring and connection to the AC power line must be...

Page 76: ...press directly upon the cable itself Cable clamps must also be applied close to the wires coming from the power supplies so that they won t be accidentally pulled out of the power supply terminals to which they are connected Avoid running cables with sharp bends or that rest on sharp edges which can damage them over time and in the long run pose a danger inside the cabinet After making all the wir...

Page 77: ...C installation By using ActiveSync copy in the BACKUP folder the following files APC EXE executable APC_EN xml english language help CpodC2 HEX cradle s latest firmware provided by Datalogic Mobile s r l 5 4 2 Starting program Run APC exe application The screen displays the APC version and the mode to interact with the cradle read or write The upper left key close the application and come back to ...

Page 78: ...adle s slot and the result will look as the right picture Cradle locks terminal in the slot the terminal top flashes three times At the end approach a magnet to the sensitive area to unlock and extract the terminal If user does not insert Joya into a slot a timeout message is displayed asking to remake the operation In case of errors a suitable message is displayed ...

Page 79: ...proach a magnet to the sensitive area to unlock and extract the terminal APC shows a suitable message to inform user if update is correctly completed or an error has been occurred 5 5 JOYATM JOYATM CRADLE DISPENSER CONNECTION Joya Cradle Dispenser is equipped with an electrical serial connection used to exhange command and response with Joya The communications between the terminal inserted into th...

Page 80: ... Dispenser ID is string of 1 byte IP address is a string of bytes Port ID is a string of 2 bytes Using this four byte strings it is possible to setup and identifiy each slot in a unique way This Config Parateters are stored in the permanent memory location dedicated of each slot They can be configured making use of the ABC companion tool and they can be read by a well inserted Joya 5 7 USE AND FUN...

Page 81: ...tance 1 2 m 3 9 ft Hardware Features FLASH 128 MB RAM 128 MB Microprocessor Intel PXA 270 312 520 MHz Audio Beeper Polyphonic audio LEDs Datalogic Green Spot Top bottom Lighting Bumper Display TFT LCD 65K Color 2 8 with 320 x 240 pixel resolution QVGA with LED backlight and touch screen Keyboard 6 fully programmable keys backlight feature Battery must be charged at a temperature ranging from 0 to ...

Page 82: ...mming Features Operating system Windows CE 5 0 Laser Optical Features Light source laser scanner Visible laser diode laser class 2 Scan rate 100 scans sec Safety class Class II EN 60825 1 Decoding features Decoded barcodes 1D GS1 Databar UPC EAN Code 39 Two of five Plessey Codabar Code 128 Code 11 Code 93 MSI ...

Page 83: ...TEST CODES 61 7 7 TEST CODES High Density Codes 0 25 mm 10 mils Code 39 17162H 17162 2 5 Interleaved Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 80 EAN 13 x 0B2DE5 KKKKLM 80 EAN 8 6450 TRMN ...

Page 84: ...DATALOGIC JOYA 62 1 7 Medium Density Codes 0 38 mm 15 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 100 EAN 13 x 0B2DE5 KKKKLM 100 EAN 8 6450 TRMN ...

Page 85: ...TEST CODES 63 7 Low Density Codes 0 50 mm 20 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 120 EAN 13 x 0B2DE5 KKKKLM 120 EAN 8 6450 TRMN ...

Page 86: ...mat Baud Rate A measure for data transmission speed Bit Binary digit One bit is the basic unit of binary information Generally eight consecutive bits compose one byte of data The pattern of 0 and 1 values within the byte determines its meaning Bluetooth A standard radio technology using a proprietary protocol The onboard Bluetooth module in the mobile computer is compatible with the 1 1 protocol B...

Page 87: ...l charges causing them to reflect light outside according to their bias They use little electricity and react relatively quickly They require external light to reflect their information to the user Light Emitting Diode LED A low power electronic light source commonly used as an indicator light It uses less power than an incandescent light bulb but more than a Liquid Crystal Display LCD RAM Random ...

Page 88: ...neral View xix Glossary 64 J Joya TM cradle dispenser 45 L Laser Safety ix M Maintenance 40 Microsoft ActiveSync 30 Model Description 1 P Package Contents 2 Patents xvii R Radio Compliance xiv Reader Parameters 15 Reference Documentation vii References vii Registry 18 Replacing the Batteries 41 Resetting the Joya 11 S Safe Setup 20 Safety Regulations viii Save Session 20 Scan Parameters 15 Startup...

Page 89: ...Erklärung basiert darauf daß das Produkt den folgenden Normen entspricht Esta declaración se basa en el cumplimiento de los productos con la siguientes normas ETSI EN 301 489 17 v1 2 1 August 2002 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS ERM ELECTROMAGNETIC COMPATIBILTY EMC STANDARD FOR RADIO EQUIPMENT AND SERVICES PART 17 SPECIFIC CONDITIONS FOR 2 4GHZ WIDEBAND TRANSMISSION SYSTEM...

Page 90: ...agnetic compatibility and product safety Basée sur la législation des Etats membres relative à la compatibilté électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnétic...