background image

CAUTION

•

Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal

circuitry may suffer damage and the product warranty will be void.

•

Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).

•

Keep circuit boards in their antistatic bags when they are not in use.

•

Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.

•

For more complete information on electrostatic discharge safety
precautions, refer to Bellcore

TM

 Technical Reference # TR-NWT-000870.

Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered

Printed in the U.S.A.

I

NSTALLATION

 & O

PERATION

 M

ANUAL

00330-1199 <90-00045>

00330 DTSS3A

S

ELECTIVE

 S

IGNALING

 O

RDER

W

IRE

 T

ERMINAL

About this Practice:

This practice has been reissued to:
• Update Fig. 2.

Issue date:  November 1999

Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.

UPDATED

Table of Contents

Ordering Information ............................................................................  2
General Description ...............................................................................  2
Installation ............................................................................................  3
Operation .............................................................................................  14
Technical Specifications.......................................................................  15
Warranty .............................................................................................  16

Summary of Contents for 00330

Page 1: ...ioactive fields For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1999 by Dantel Inc Dantel is a registered tr...

Page 2: ...provides voice coupling and DTMF decoding for a telephone headset and loudspeaker in a selec tive signaling order wire system The DTSS3A comes in a housing measuring 15 3 8 W x 7 7 8 D x 1 3 4 H It c...

Page 3: ...idge for repeater applicatons where the levels are not 7 dBm RCV 16 dBm XMT The terminal operates on 22 to 56 VDC input power GENERAL DESCRIPTION INSTALLATION Installation of the 00330 consists of mou...

Page 4: ...56 VDC D1 J5 55 49 Ring Enable Sta 1 Out Pwr up Busy Sta 2 Out 16 dBm 7 dBm 12 5 External Speaker Lamp 50 mA max P1 44022 Station Interface J2 Bypass Bridge Bypass Switch Bridge A B C D S1 In 1 Out I...

Page 5: ...ire terminal 3 SWITCH AND STRAP SETTINGS Refer to Tables A through F and Figs 3 through 8 to set the straps and switches on the modules and DTSS3A backplane 44020 DTMF Decoder Refer to Table A and Fig...

Page 6: ...E 6 00330 1199 90 00045 FIG 3 SWITCH AND STRAP LOCATIONS 44020 INSTALLATION CONTINUED 1 12 J1 1 12 J2 C2 2 A2 2 C1 1 A1 1 16 DGT 12 0DB 10DB 10DB IN DTF OUT BRDG 600 OHM OR A OR C CLR EXT CLR PLS EXT...

Page 7: ...CATIONS 49018 OPTION Reset 3 second reset ExternalorTone Number of Digits 1 digitCodes 2 digitCodes 3 digitCodes Station CallCode First Digit SecondDigit Third Digit All CallCode First Digit SecondDig...

Page 8: ...et ExternalorTone Number of Digits 3 digitCodes 4 digitCodes 5 digitCodes 6 digitCodes Circuit 1 Code 3 digitCodes 4 digitCodes 5 digitCodes 6 digitCodes Circuit 2 Code CallCancellation Tone Tone SETT...

Page 9: ...ad Driver Off Hook Privacy Auto or Manual None 2W 4W Drop 2 Wire 4 Wire Sidetone 4W with Sidetone 4W without Sidetone 2W all uses 4W Drop RCV 600 ohms 0 ohms Ring Generator None External SETTINGS GP I...

Page 10: ...0 INTERRUPT SUPPLY MODULE INSTALLATION CONTINUED OPTION Interrupt Normal Reverse RingbackTone Continuous Cycling Defeated SpeakerControl S1 Automatic ExternalControl Buzzer S2 Operational Defeated SET...

Page 11: ...nal ground Floatingchassisground J5 No external ringing generator External ringing generator see Note 2 of Fig 2 J7 SETTINGS S1 BYPASS S1BRIDGE S2 IN S2 OUT S3 IN S3 OUT IN OUT IN OUT Do not change Fa...

Page 12: ...t o t r e t e m m h o 0 0 6 d e t a n i m r e t a t c e n n o C C t n o r f s e l u d o m 2 2 0 4 4 e h t n o s t n i o p t s e t E N I L T M X l e n a p T M X t e S l e v e l t i m s n a r t s w o h...

Page 13: ...22 X0 STATION INTERFACE INSTALLATION 44022 00 STATION INTERFACE XMT LINE TP GND LINE DROP MON TRANSMIT DIST GND LINE DROP MON RECEIVE DIST RCV LINE TP XMT LEVEL ADJUST TEST RESET SWITCH Busy Inc Call...

Page 14: ...e is available take the phone off hook and dial the desired station using the appropriate station call number code To call all stations on the system dial the all call number The buzzer will sound at...

Page 15: ...i t a g e n o t r o t c e l l o c n e p O t n e m e r i u q e R r e w o P t u p n I e l d I d a o L l l u F A m 0 7 A m 0 5 1 n o i t a p i s s i D t a e H e l d I d a o L l l u F r H u t B 6 9 r H u...

Page 16: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...