background image

TE-W2

 

Thermal Image Camera 

User Manual 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

Summary of Contents for TE-W2

Page 1: ...TE W2 Thermal Image Camera User Manual ...

Page 2: ...ent damage may result CAUTION The original shipping carton should be kept for use for future transportation Do not drop shake or impact the thermal imager excessively in use or during transportation CAUTION Store the unit in its original case in a cool dry well ventilated area away from strong electromagnetic fields CAUTION Protect the surface of the lens from being stained or damaged by foreign o...

Page 3: ...3 CAUTION Do not open case Unit does not contain any user serviceable parts Repair should be performed by factory authorized technicians only ...

Page 4: ... 3 3 2 Temperature Measurement 17 3 3 3 Save Image 18 3 3 4 Playback Image 18 3 3 5 Download the Save Files 18 3 3 6 Screen Setting 18 3 3 7 Manu Operation Introduction 18 4 Operation guide 19 4 1 Graphic interface description 19 4 1 1 Screen graphic interface 19 4 1 2 Floating Bar Interface 21 4 1 3 Main Manu 21 4 1 4 Sub manu interface 22 4 2 Measurement Object Adding 22 4 3 Recording 23 4 4 Pho...

Page 5: ...n 46 5 2 Surveillance image 46 5 3 Function operate 47 5 3 1 System parameter set 47 5 3 2 Photo Setting 48 5 3 3 Graphic setting 49 5 3 4 Measurement Setting 49 5 3 5 Network 50 5 3 6 Local Settings 50 5 3 7 System Maintainance 50 6 Configuration 52 7 Troubleshooting 54 1 Introduction Thank you for choosing Instruments TE W2 hand held infrared thermal ...

Page 6: ... shortcuts Blue tooth Power saving mode LCD Brightness adjustment Video Output NTSC or PAL Internet settings Time and Date settings Factory settings restore TF card uninstall formatting TF card image storage video storage Text and Audio annotation via image storage Consecutive image shot storage Alarm image capture Alarm video record Isotherm measurement function Temperature measurement settings B...

Page 7: ... moisture and mildew Evaluation Evaluate the resolution to ensure the area completely dry Others Iron and steel industry Inspect steel refining and rolling processes diagnose hot blast stove defects detect the embryo temperature of armor plate etc Fire fighting Forest fire prevention and detection of latent ignition source Preventive detection on specific materials of auto ignition Detection of po...

Page 8: ...anual Infrared report and analysis software system CD Lithium battery charger Lens cap TF card TF card reader USB cable Black body 1 2 Optional accessories External 0 5x wide angle lens External 2x telescopic lens Eye patch Power adapter with power cable and plug European standard plug British standard plug Australian standard plug ...

Page 9: ...9 2 Camera overview 2 1 Function keys 2 3 1 4 5 6 7 ...

Page 10: ...ss Menu to set properties press C to delete the Selected measuring objects Color Palette Pressing the left or right arrows will scroll through the available color palettes displaying their name above the palette The selected palette will become active after about 3 seconds of selecting it and will be set as the default power on palette Level Span values Pressing the left or right arrow will reduce...

Page 11: ... image Press Confirm to save the image or Press C to return to real time measurement If Audio recording is enabled Audio comment dialog box will display In document management press S to delete video or image 5 Menu Confirm key bar Includes Up Down Left Right and Menu Confirm center keys Function varies with operation mode In Menu mode it is used for menu selection Up and Down keys are for same le...

Page 12: ...ding an area or by selecting via the A key press the Confirm key to pop up the attribute box Select in the attribute box the parameter to be edited either size or position Press the four navigation keys to move the area location or change the size of the area 6 Trigger Shortcut key The trigger key serves as a shortcut to access the following functions Laser Pulling trigger activates laser sight an...

Page 13: ...ard slot Accepting standard size TF card such as supplied 8GB capacity card for device upgrade or image storage 3 Video port It is a video output interface 4 Power interface External power input interface Power source should be 12VDC Center pin is positive terminal 1 4 2 3 ...

Page 14: ... Replacement 3 1 1 Inserting or removing battery Battery compartment is located inside the handle Turn the cover counter clockwise to remove Remove battery for replacement Insert the battery the battery contacts must face into the battery compartment ...

Page 15: ... or electrical damage to the instrument due to incorrect voltage or physical size difference 3 1 2 Replacing battery When battery displays empty and flashes for about 1 minute and 50 seconds the instrument displays a low battery dialog and shut down automatically after about 10 seconds Powering off display It s better to replace batteries now ...

Page 16: ... should be 32 F 0 C to 104 F 40 C If under 32 F 0 C the battery capacity will be diminished if over 104 F 40 C the battery may overheat resulting in permanent damage WARNING Never disassemble incinerate or puncture battery Never short circuit the battery Keep battery dry Keep out of reach of children Always dispose of battery in accordance with local state and federal regulations 3 3Quick access 3...

Page 17: ...urement Let the target move to the cross point the number shown at the up right corner is the temperature of the cross point If you want more accuracy measurement you can measure after pressing the button A for 3 seconds Switch the imager into fusion mode Point the thermal imager at the blackbody which is about 2 meters far away press the navigation button down display Base point Calibrate menu as...

Page 18: ...the Preview option in the floating panel to open the selected file via the left and right keys to switch selection After you open the image you could use upper and lower sections of the playback control panel keys to playback the current store images Press Cancel key to exit and return to the current state 3 3 5 Download the Save Files Can use card reader to download delete format the TF files Not...

Page 19: ...ce The up and down key is to modify the left and right key is to choose means modify the setting of the current manu Press the OK button to confirm the changes save and return to the previous menu press the C key to cancel the changes and return to the previous menu Cancel and return to the previous menu button Save and return to the previous menu button For touch screen Switch button by the left ...

Page 20: ...al Enhancement select manual enhancement mode 9 Palette palette bar User can choose different palettes 10 Bluetooth select Bluetooth function 11 Max temperature indicate the max value of the palette 12 Battery status indicate the current battery status 13 TF card indicate the TF card load status 14 Freeze logo indicate the current image is frozen 15 Zoom indicate the image is zoomed 16 Recording i...

Page 21: ...ing bar interface Floating bar interface From left to right is namely the temperature measurement video photo preview and settings manu 4 1 3 Main Manu Main Manu The main menu items display the main menu item namely the document management temperature settings image settings camera settings general settings network settings TF card ...

Page 22: ...hown in the above figure 3 Item Content each item corresponds to the content of a project the left and right keys to make changes indicates the lower menu 4 Parameter options press the left button to select a different parameter 4 2Measurement Object Adding This feature is used to increase or clear the measuring object The following dialog box pops up press the Enter key floating menu pops up sele...

Page 23: ...he C key to delete 4 3Recording This function is used to save the video save format to MP4 Pressing the Enter key floating menu pops up select video and press the Enter key as shown below Recording Figure Press stop key to end the recording and return to the current operation status 4 4Photo This item is for photo And back up in the JPG format Pop up the floating menu after pressing confirming key...

Page 24: ...column if set the continuous photo 4 5Preview This item is for the preview files of backup Press confirming key Pop up the floating items select preview and press confirming key will appears as followed Preview OSD Switch to files by pressing key of left or right Open it and it appears in the screen by pressing confirming key Press C key to quit ...

Page 25: ...ming key Users could set the time of auto calibration definition of shortcut key Bluetooth pattern of power saving brightness adjustment of LCD unit of temperature unit of distance totally 7 items Switch to items by pressing key of up or down Change the value by pressing key of left or right means secondary menu and enter the menu by pressing key of right Time of Auto calibration Set time interval...

Page 26: ...emperature Adding or removing area 1 of testing temperature and so on When select shortcut key of laser It will open the aimer of laser Then it closes When select shortcut key of light It will open the lighting Then it closes When select shortcut key of spot 1 It will add or remove the spot 1 When select shortcut key of area 1 It will add or remove the area 1 When select shortcut key of record It ...

Page 27: ... device will scan and search one time automatically Bluetooth OSD Power saving Screen off and power off Time of scree off If without any operation thermal imaging camera will screen off to save power Press any key except the power key thermal imaging camera will screen on This function is not valid when time is set to 00 minute Time of power off If without any operation thermal imaging camera will...

Page 28: ...28 Power saving OSD LCD brightness adjustment It is valid when changing the brightness LCD brightness adjust OSD 4 6 1 Measuring setting ...

Page 29: ...wn button to select means there is sub menu press Right Button to enter the sub menu Level Seeting the Measuring Level of the thermal camera Magnification Seeting the Magnification and the different Temp range Environment Temp It will automaticly detect the Environment Temp after the camera start up Ref Temp When it is enabled the target temperature shown on the LCD is the D Value between the real...

Page 30: ...has different emissivity so the user can set different emissivity for different target If it is not set then will use default setting Attached Common emissivity table for reference Tcorrect Correct the target Temperature Distance Setting the distance between the camera and the target to make sure exact measuring Set the real distance if the distance is shorter than 10 meters unit 0 5m Humidity Set...

Page 31: ...r analysis purpose When Auto Enhance Mode is activated can switch between manual and automatic Press A button will enter manul mode it can adjust the pallet with UP Down LEFT Right buttons Press C will return into Auto Mode When Auto Enhance Mode is deactivated can switch between manual and automatic Press A button will enter manul mode it can adjust the pallet with UP Down LEFT Right buttons Pres...

Page 32: ... User cab set alarm OFF High temp alarm Low temp alarm here It will alarm when proper setting is selected Alarm color can be set in Alarm Color Alarm Color The color of the target area shown on the LCD will be changed into the alarm color set when the temperature is over the alarm temp 9 color types can be selected If colorless is selected then the color will not change when alarm Alarm Temperatur...

Page 33: ...Off disables the feature Isotherm low value Set the Isotherm low value Isotherm upper value Set the Isotherm upper value IR Fusion High Low temperature Menu IR Fusion High Low temperature It consists of three options IR Fusion High Temp IR fusion Low Temp and OFF Set IR Fusion High Temp when the actual temperature is higher than the temperature of IR fusion set up CCD image will be shown Vice vers...

Page 34: ...elect Network function IP Address This IP address must be the only one can not be conflicted with the other IP address of the same network segment Sub network mask Divide the segment of the sub network Default network gateway Set the gateway address to realize the communication among different segment Link type Default 10M 100M self adapt 10M 100M ...

Page 35: ...35 4 6 5 TF Card Management TF Card Management Figure TF Unload TF Card Format Figure ...

Page 36: ...F card Select the formatting options pressing the confirm key to format press cancel or C key to cancel the formatting Note Verify that the file is no longer needed or have been backed up before formatting after formation the saved thermal imaging pictures will be lost unrecoverable If format by PC please select FAT16 to format the card 4 6 6 Photo Setting Photo Setting Manu Pressing confirm key t...

Page 37: ...ons Audio annotations is to add voice when you save the picture text annotation is to add text messages when save the image CS Shots Set Continuous capture the number of sheets can be set for 1 3 5 10 shot Continuous Capture Interval can be 0 5s or 1s Record Time can set 1 3 5 10 or 15 minutes to shut off the recording Manu Setting Manu Setting Set the path to save the file directory type can be s...

Page 38: ...stomize the set system language time date formats time date restore the factory value items Pressing the up down key to switch the setting use left and right arrow keys to set the contents of the setting The indicates that there s a lower level menu use right click to enter Language Set the languages Time Date Format Time Date Setting Manu Change the format of the time date ...

Page 39: ...due to the limited internal battery power the thermal imaging camera need to re adjust the system time Restore the factory settings This function is used to restore the factory settings Pressing the confirmation button the setting manu will come up continue to press the confirm key system to restore the factory settings When pressing the cancel button to exit the restore the factory settings will ...

Page 40: ... device number software version number and MAC address Import New TF card the Create DCIM Import directory on the TF card import the fixed file name as PicNote cfg File Name Form Note Note1 Note2 Note3 Each line is not more than 20 words After the import is complete restart the instrument to take effect Export TF card make sure the TF card is in the machine then select the ...

Page 41: ...ode press the Enter key to pop up floating panel select Settings option to activate the main menu select the file management menu in the setup menu press the confirm button to open the infrared image in the storage The image arrangement format has abalone grid press the upper lower left and right arrow keys can switched the stored image Pressing the C key to exit open image and return to the measu...

Page 42: ...ress the OK button to enter the playback Pressing the C key to exit open image and return to the measurement state Video Playback Interface Video playback interface Via the left and right key to select the play button on the status bar press the confirm key to take effect on the next key to show and hide the playback status bar press the on button is displayed press the next button is hidden ...

Page 43: ... the playback status bar press the on button is displayed press the next button is hidden The icon buttons from left to right is as follows the former one above the next paragraph sound recording voice playback text playback 4 7 2 Bluetooth Transmission This function is used to transfer the stored images on TF card First turn on Bluetooth then open the file manager and the arrow keys to select the...

Page 44: ...ction is used to delete data stored in files on the TF card Open File Manager by the up and down keys to select the file you want to delete press the S key to bring up the prompt box delete the currently selected image files when the Enter key is pressed the image voice or text comments will also be deleted then press the C key to undelete ...

Page 45: ...45 File Delete Figure Note Before deletion make sure that the file is no longer needed or have backup the deleted image can not be recovered ...

Page 46: ...te menu after press the login If ActiveX cannot download automatically please download manually 5 2Surveillance image Surveillance image will be shown as follow Monitoring Figure Switch Switch on off to open and close the image Link save save the thermal image and visual image both Local capture Save image in BMP format Local record Save the video in AVI format ...

Page 47: ...ames Frames rate means frames per seconds Could set as different modes like continuous 5 20 50 100 random Interval time means time between two frame it could also set different modes like 20 40 100 200 1000 random 5 3Function operate Press buttons are shown in the left in the screen Buttons 5 3 1 System parameter set System parameter menu will pop up after login ...

Page 48: ...clude the setting for time for system setting and for the short key see as the operation guide 5 3 2 Photo Setting Click photo setting and come to the setting manu see as the follow Photo Setting The details please see as the operation guide ...

Page 49: ...ic setting another is the alarm setting 5 3 4 Measurement Setting Click the measurement setting and see as follow Measuring Parameters Menu Under Measuring Parameters Menu there are sub menu of Measuring Settings measuring correction and isothermal For the detailed function operation please refer the operation manual ...

Page 50: ...tion manual for the detailed functional descriptions 5 3 6 Local Settings Press Local settings can enter into local settings menu Refer below picture Menu of local settings Default Vedio port number is 5000 The file saving path can be defined by user 5 3 7 System Maintainance Press System Maintainance will show menu as below picture ...

Page 51: ... description Press Firmware update it will switch into upgrade interface as below Hardware Upgrade Figure upload download configuration click this function and will seeasfolow upload download configuration figure System State Click system situation then will see System State Figure ...

Page 52: ...l to adjust brightness contrast Image Fast switch between infrared image and ccd image with fusion function Image Enhance Auto manual enhance mode Meas urem ent Range 30 42 Accuracy 1 C Measurement Correction Auto Manual Mode Up to 5 movable spots Up to 5 movable areas maximum minimum and average temperatures Up to 2 movable lines Line profile Isotherms Temperature difference Alarm voice color Emi...

Page 53: ...igent charge or power adaptor or 12v car power charge Charging time 1 5 hour to 50 full Power saving auto sleep auto shut down Interf ace SD card slot Micro SD TF slot Net Mini USB power DC12V video yes Auto data Bluetooth earphone RS232 other Mic yes buzzer yes Flash light 2 LED Laser point red 1mw 635nm two level IEC60285 Triple 1 4 20 UNC Hand strap Can install on two side Lens cover yes Sky sh...

Page 54: ...led Wait for 5 seconds and reboot The camera powers off automatically Battery is out of power Change battery Auto Off Time option is enabled Set as None Battery depletion is too fast Environmental temperature is too low Rechargeable battery is not charged completely Recharge the battery Rechargeable battery is out of power completely and cannot be recharged Change to new battery No thermal image L...

Reviews: