GENERIC SERVICE 

VANGUARD

®

 VC6 

LARGE MATRIX SERIES

DISPLAY MANUAL

17 October 2018

DD4007298

Rev 00

Содержание VANGUARD VC6

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 GENERIC SERVICE VANGUARD VC6 LARGE MATRIX SERIES DISPLAY MANUAL 17 October 2018 DD4007298 Rev 00 ...

Страница 2: ...part of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or information storage and retrieval systems without written permission of the publisher Daktronics trademarks are property of Daktronics Inc All other trademarks are property of their respective companies ...

Страница 3: ...l Connections 10 6 Start Up Procedure 11 Start Up Checklist 11 7 Network and Communication Installation 12 Network and Communication Installation Dos 12 Vanguard Software 12 8 Display Maintenance 13 Internal Display Access 13 Ventilation System 14 Display Face Cleaning 14 Wet Cleaning Process 14 Dry Cleaning Process 14 9 Display Troubleshooting 15 Power and Signal Routing 15 Power Routing 15 Signa...

Страница 4: ......

Страница 5: ...nd little maintenance However from time to time certain display components need replacing Refer to the Daktronics Exchange and Repair Return Programs p 21 section if any component needs replacement or repair Limitation of Liability The factory warranty will be nullified if The display is not installed according to the steps in this manual Proper electrical service is not provided or the display is...

Страница 6: ...nsure the display cabinet has no holes accidental or intentional that will allow water to enter the display All display modules are fully latched into the display cabinet Structure Requirements Support structure design depends on mounting method installation height display size and weight Because every installation site is unique Daktronics approves no single procedure for mounting displays Things...

Страница 7: ...es the specialized tools needed to complete the installation Daktronics Provided Customer Provided Splice Wrench Hex Head Wrenches 1 8 and 3 16 Flathead and Phillips Head Screw Drivers Crane or Lift Truck Step Ladders Computer with Vanguard Software and Internet access Ratchet and or Impact Wrench 11 16 Socket Set Sizes up to 1 1 16 Needed Tape Measure Utility Knife ...

Страница 8: ...nauthorized modifications will nullify the warranty Display Installation Dos Inspect the display for damage prior to installation Use all T clips for mounting Provide an adequate support structure that is straight and level Provide adequate ventilation that meets or exceeds display specifications Use all T clips for mounting using a continuous horizontal member Use all lift eyes when lifting the d...

Страница 9: ...s 9 Remove crane support and tag lines from the display once mounting is complete 10 Locate the top border caps and install over lift eyes using provided Tek screws Figure 1 Proper Display Lifting From Back Tag Line Tie Off Angle must be greater than 55 Lift Eye Bolts Set Bolts Note Lift eye spacing is set at Daktronics and should not be moved Lift eyes should also remain in place after installati...

Страница 10: ...e right Refer to Figure 3 Section Splicing 1 Ensure the splice key is inserted in the channel of the bottom section as shown in Figure 4 2 Attach a crane or lift truck to the lift eyes of the top section and apply tension 3 Unbolt the top section of the display from the truck bed and unbolt A frame 4 Lift the display top section off the truck high enough to spin around 180 degrees Section 201 Sect...

Страница 11: ...d and that LEDs are also in alignment 7 Attach the splice plates and splice T clips along the section splice as shown in Figure 6 Use an 11 16 impact wrench or ratchet to tighten all nuts on the splice plates and splice T clips Top Section Bottom Section Figure 5 Aligning Display Sections with Splice Tool Splice Plate Bolt Nut Washer Display Face Bottom Section Top Section Figure 6 Installed Flat ...

Страница 12: ... the product label Connect the neutral to the ground at the disconnect or the display Use the display support structure as an earth ground electrode Conduit Daktronics does not provide conduit Separate conduit must be used to route Power Signal IN wires to the signal termination enclosure when applicable Signal OUT wires if not using the provided interconnect cable For power displays have either a...

Страница 13: ...cked in the open position This ensures that power is not reconnected while service personnel work on the display Power Connection 1 Review the power requirements for the display Requirements are found on the display shop drawing or label on the display s back 2 Route conduit from the main distribution panel disconnect to each display power entrance Each display section has a power entrance and req...

Страница 14: ...ons of all applicable local and national codes Inspect and verify all grounding methods meet the provisions of all applicable local and national codes Proper grounding is necessary for reliable equipment operation and general electrical safety Failure to properly ground the display system may void the warranty disrupt operation damage equipment and cause bodily harm or death Sectional Display Sign...

Страница 15: ...rnal communication equipment signal enclosure client radio etc is properly installed Inspect signal connections at the control computer Confirm that any necessary network connections have been made Inspect peripheral equipment temperature sensor light sensor etc for proper installation Confirm that the control computer is correctly configured according to the Vanguard Software Help File F1 Note Be...

Страница 16: ... and Communication Installation Dos Complete all network and communication installation prior to turning display on Have a laptop on site with Internet access preferred Work with the customer s IT professional for network integration Vanguard Software Daktronics Vanguard software allows the VC6 operator to check display status and to control messages Refer to the Vanguard Software Help File F1 for...

Страница 17: ...he power cable by squeezing the tabs on the sides of the plug head and pulling it out 5 When ready to reinstall the module reconnect the cables push the cables into the display so they do not get pinched and latch the module using a 1 8 hex head wrench Note Component locations may vary depending on display size Refer to drawings included with the display Note Turn OFF power before any repair or ma...

Страница 18: ... cleaning brush with the soapy water 4 Use horizontal brush strokes to loosen and remove dirt and grime washing the display from top to bottom Use light pressure so as not to damage the LEDs Clean only an area that is safely within reach from a lift or stage and then move on to the next section of modules 5 Rinse the display face with generous amounts of cold water under low pressure A spot free r...

Страница 19: ...trance box on the back of the display and travels to the Power Termination Panel 2 Power is distributed to Module Power Supplies 2a Player Power Supply 2b Thermostat 2c and Fans 2d 3 DC Power is also supplied to the PLR 4 from the Player Power Supply P L R PLR Power Supply Quick Connect Input Term Panel Power Entrance Quick Connect Output Fans Light Sensor Thermostat Power Supplies PS P S P S P S ...

Страница 20: ...PLR receives signal from the display player which transfers it on to the modules through SATA cables Vanguard VC6 displays are equipped with a redundant signal path meaning two SATA cables are connected to each module If one of the two SATA cables fail the module continues to receive data from the other SATA cable and the display continues functioning normally When put into self test mode the PLR ...

Страница 21: ...rt for additional information or questions If any Err message is displayed send the PLR back to Daktronics for repair or replacement Code Description 8 8 8 Testing 7 segments held for 2 seconds t s t Initial test in progress 60 second duration P A S All tests passed E r r Test failures reported F 0 1 Fiber Port A Error F 0 2 Fiber Port B Error F 0 3 RJ45 IN Port A Error F 0 4 RJ45 OUT Port B Error...

Страница 22: ...supplied to it perform a module self test to diagnose a module or signal cable failure To perform a self test follow the steps below 1 Attach a signal cable to Port A and Port B on the module as shown in Figure 13 2 Disconnect the power to the module for 10 seconds 3 Reconnect the power to start the self test 4 Verify the module is running a self test Remove the signal cable and cycle power to the...

Страница 23: ...reconnect the cables push the cables into the display so they do not get pinched and latch the module using a 1 8 hex head wrench Power Supply Replacement 1 Disconnect the power supply from any wiring harnesses connected to it as shown in Figure 14 2 Pull the top tab of the power supply bracket outward 3 Slide the bracket up and pull it out of the cabinet 4 Push the tab holding the power supply in...

Страница 24: ...ror display faces as well as all sections of a sectional display 1 Remove the module in front of the PLR 2 Disconnect the two SATA cables fiber cables and power cable to the PLR 3 Loosen the screw at the top of the PLR mounting plate 4 Lift the mounting plate up and out of the display 5 Insert the new PLR with mounting plate and tighten the screw 6 Insert the two SATA cables fiber cables and power...

Страница 25: ...ts within this display carry a label listing the part number of the unit If a circuit board or assembly is not in the replacement parts list use the label to order a replacement A typical label is shown in Figure 15 The part number is bolded Daktronics Exchange and Repair Return Programs To serve customers repair and maintenance needs Daktronics offers both an Exchange Program and a Repair Return ...

Страница 26: ...ely Daktronics expects immediate return of an exchange part if it does not solve the problem The company also reserves the right to refuse parts that have been damaged due to acts of nature or causes other than normal wear and tear Repair Return Program For items not subject to exchange Daktronics offers a Repair Return Program To send a part for repair follow these steps 1 Call or fax Daktronics ...

Страница 27: ...Daktronics Exchange and Repair Return Programs 23 Shipping Address Daktronics Customer Service 600 E 54th St N Case ____________ Sioux Falls SD 57104 Email transportationhelp daktronics com ...